York DM150 manual Blower Performance 12-1/2 TON Downshot Imperial, 100 149 199 249 299 349 399 448

Page 28

036-21044-003-A-0304

TABLE 31: BLOWER PERFORMANCE 12-1/2 TON - DOWNSHOT (IMPERIAL)

 

 

 

 

 

 

 

 

 

 

Turns Open

 

 

 

 

 

 

 

 

ESP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

3

 

 

4

 

 

5

 

(iwg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Watts

BHP

CFM

Watts

BHP

CFM

Watts

BHP

CFM

Watts

BHP

CFM

Watts

BHP

CFM

Watts

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.4

 

5576

4015

4.32

5370

3547

3.80

5171

3197

3.43

5007

2884

3.09

4721

2515

2.70

4344

2145

2.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.6

 

5376

3839

4.12

5147

3376

3.62

4929

3022

3.24

4735

2704

2.90

4450

2353

2.52

4048

1991

2.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.8

 

5155

3652

3.92

4908

3197

3.43

4668

2841

3.05

4411

2501

2.68

4151

2183

2.34

3717

1829

1.96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

4915

3456

3.71

4651

3013

3.23

4388

2656

2.85

4035

2281

2.45

3825

2008

2.15

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

 

4653

3253

3.49

4377

2823

3.03

4089

2467

2.65

3608

2051

2.20

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.4

 

4372

3046

3.27

4087

3621

2.82

3771

2277

2.44

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.6

 

4070

2837

3.04

3780

2437

2.61

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.8

 

3748

2629

2.82

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 32: BLOWER PERFORMANCE 12-1/2 TON - DOWNSHOT (METRIC)

 

 

 

 

 

 

 

 

 

Turns Open

 

 

 

 

 

 

 

 

ESP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

3

 

 

4

 

 

5

 

(Pa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m3/s

In

Out

m3/s

In

Out

m3/s

In

Out

m3/s

In

Out

m3/s

In

Out

m3/s

In

Out

 

 

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

2.63

4.01

3.21

2.53

3.55

2.84

2.44

3.20

2.56

2.36

2.88

2.31

2.23

2.51

2.01

2.05

2.15

1.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

149

2.54

3.84

3.07

2.43

3.38

2.70

2.33

3.02

2.42

2.23

2.70

2.16

2.10

2.35

1.88

1.91

1.99

1.59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

199

2.43

3.65

2.92

2.32

3.20

2.56

2.20

2.84

2.27

2.08

2.50

2.00

1.96

2.18

1.75

1.75

1.83

1.46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

249

2.32

3.46

2.76

2.20

3.01

2.41

2.07

2.66

2.12

1.90

2.28

1.83

1.81

2.01

1.61

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

299

2.20

3.25

2.60

2.07

2.82

2.26

1.93

2.47

1.97

1.70

2.05

1.64

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

349

2.06

3.05

2.44

1.93

2.63

2.10

1.78

2.28

1.82

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

399

1.92

2.84

2.27

1.78

2.44

1.95

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

448

1.77

2.63

2.10

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES FOR TABLES 13 THROUGH 32:

“Turns Open” refers to the setting of the variable pitch motor sheave, where “0 Turns Open” is fully closed.

Blower performance includes dry coil and 2” (51mm) throw-away filters.

Blower performance for gas heat includes the maximum number of heat tubes available for each tonnage.

ESP (External Static Pressure) given is that available for the supply and return air duct system. All internal resis- tances have been deducted from the total static pressure of the blower.

28

Unitary Products

Image 28
Contents Technical Table of Contents Predator Component Location Environmentally Aware For036-21044-003-A-0304 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit ½ 12½ Ton Predator Model Number Nomenclature Nomenclature Additional OPTIONSì Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Physical Data Component Models 090 120 150Capacity Ratings Imperial Capacity Ratings MetricCooling Capacity 7-1/2 TON Unit Imperial Cooling Capacity 26.4 KW Unit Metric M3/sCooling Capacity 10 TON Unit Imperial 35004000 4500Cooling Capacity 35.1 KW Unit Metric Cap.1 Input2 Return Dry Bulb CCooling Capacity 12-1/2 TON Unit Imperial 43755625 6250Cooling Capacity 43.9 KW Unit Metric Electrical Data 10 TON Electrical Data 7-1/2 TONElectrical Data 12-1/2 TON Turns Open 100 149 199 249Blower Performance 10 TON Standard Motor Side Duct Imperial Blower Performance 10 TON Standard Motor Side Duct Metric100 149 199 249 299 349 399 100 149 199 249 299 349Blower Performance 10 TON Optional Motor Side Duct Metric Blower Performance 10 TON Optional Motor Side Duct Imperial100 149 199 249 299 349 399 448 498 548 Blower Performance 12-1/2 TON Side Duct Metric Blower Performance 12-1/2 TON Side Duct Imperial100 149 199 249 299 349 399 448 498 Blower Performance 7-1/2 TON Standard Motor Downshot Metric Blower Performance 7-1/2 TON Optional Motor Downshot Metric Blower Performance 10 TON Standard Motor Downshot ImperialBlower Performance 10 TON Standard Motor Downshot Metric 100 149 199 249 299Blower Performance 10 TON Optional Motor Downshot Imperial Blower Performance 10 TON Optional Motor Downshot MetricBlower Performance 12-1/2 TON Downshot Metric Blower Performance 12-1/2 TON Downshot Imperial100 149 199 249 299 349 399 448 Additional Static Resistance Imperial Cooling Only1 Economizer2 Electric Heat KW2Additional Static Resistance Metric Electric Heat Minimum Supply AIR ImperialElectric Heat Minimum Supply AIR Metric 12.5Indoor Blower Specifications Point Load WeightUnit Weight Model Location lbs. kg 090Detail B Unit ClearancesDetail C Detail D RightPredator Roof Curb Dimensions Bottom Duct Openings from Above Cooling Unit with GAS Heat Wiring Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram Unitary 5005 Norman Products York Group Drive 73069

DM120, DM150 specifications

The York DM120 and DM150 are advanced rooftop packaged units designed for commercial applications, offering high efficiency, reliability, and user-friendly features. These models are part of York's extensive range of HVAC solutions, aimed at meeting diverse heating, ventilation, and air conditioning needs.

One prominent feature of both the DM120 and DM150 is their streamlined, compact design, which allows for easy installation and fits seamlessly onto rooftops. These units are engineered to maximize space while ensuring high performance. With their robust construction, they are built to withstand harsh weather conditions, ensuring longevity and durability.

The DM120 is designed to provide a cooling capacity of up to 12 tons, whereas the DM150 can reach up to 15 tons. Both models utilize environmentally friendly refrigerants, which contribute to reducing the overall carbon footprint. This makes them a sustainable choice for businesses looking to enhance their environmental responsibility.

In terms of efficiency, both units are equipped with high-efficiency scroll compressors that optimize energy usage, lowering operational costs. They also feature advanced heat exchanger designs that enhance heat transfer efficiency, ensuring consistent indoor comfort while minimizing energy consumption.

User-friendly controls are another hallmark of the York DM120 and DM150. They come with an intuitive interface that allows for easy adjustments and monitoring of system performance. Advanced controls support integration with building management systems, enabling remote monitoring and control for enhanced operational efficiency.

The DM120 and DM150 also prioritize indoor air quality. They incorporate advanced filtration systems that capture airborne particles and improve ventilation, contributing to healthier indoor environments. Furthermore, these models come with variable-speed fans that adjust airflow based on current conditions, optimizing comfort while reducing noise levels.

The models are also designed for serviceability, allowing technicians easy access to critical components for maintenance. This feature not only prolongs the lifespan of the units but also minimizes downtime, keeping commercial spaces comfortable and operational.

In summary, the York DM120 and DM150 units represent an ideal balance of efficiency, technology, and reliability, making them suitable for various commercial applications. Their robust features, commitment to sustainability, and focus on user convenience make them a valuable investment for businesses seeking to improve their HVAC systems.