York DM150, DM120 manual 036-21044-003-A-0304

Page 4

Balanced Heating – The Predator® offers “Ultimate Heating Comfort” with a balance between 1st and 2nd stage gas heating. The 1st stage of a gas heat Predator® unit provides 60% of the heating capacity. Balanced heating allows the unit to better maintain desired temper- atures.

Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side sup- ply/return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory.

System Protection - Suction line freezestats are sup- plied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and low-pressure switches. Internal compressor protection is standard on all compressors. Crankcase heaters are standard on reciprocating compressors. Scroll compres- sors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation.

Advanced Controls - 3FJMIF@FQV™ control boards have standardized a number of features previously available only as options or by utilizing additional controls.

Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0°F (-17.8°C) outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available.

Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button.

Fan Delays - Fan on and fan off delays are fully pro- grammable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat.

Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit con- trol board will alarm on ignition failures, compressor lockouts and repeated limit switch trips.

036-21044-003-A-0304

Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor.

On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power.

Reliable – From the beginning – All units undergo com- puter automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit

amperage, and 100% functionality. For the long term – All Predator® units are painted with a long lasting, pow- der paint that stands up over the life of the unit. The paint used has been proven by a 750 hour salt spray test.

Flexible Placement – All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the internal loads have been determined.

To further simplify planning and installation, Predator® cabinets are designed to fit your roof. With the optional roof curb, the unit ductwork is designed to fit around 24” (610 mm) on-center joists or between 48” (1219 mm) on- center joists.

The drain pan can be rotated to drain to either the front or the rear of the unit. Additionally, the drain pan can be piped to drain through the roof curb. As it is sometimes difficult to have a level installation, the drain pan features a generous slope to ensure proper drainage.

Full Perimeter Base Rails – The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer fork- lift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof.

Easy Installation – Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility con- nections can be made quickly and with a minimum amount of field labor.

All units are shipped with 2” (51 mm) filters installed.

4

Unitary Products

Image 4
Contents Technical Table of Contents Predator Component Location Environmentally Aware For036-21044-003-A-0304 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit ½ 12½ Ton Predator Model Number Nomenclature Nomenclature Additional OPTIONSì Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Physical Data Component Models 090 120 150Capacity Ratings Imperial Capacity Ratings MetricCooling Capacity 7-1/2 TON Unit Imperial Cooling Capacity 26.4 KW Unit Metric M3/sCooling Capacity 10 TON Unit Imperial 35004000 4500Cooling Capacity 35.1 KW Unit Metric Cap.1 Input2 Return Dry Bulb CCooling Capacity 12-1/2 TON Unit Imperial 43755625 6250Cooling Capacity 43.9 KW Unit Metric Electrical Data 10 TON Electrical Data 7-1/2 TONElectrical Data 12-1/2 TON Turns Open 100 149 199 249Blower Performance 10 TON Standard Motor Side Duct Imperial Blower Performance 10 TON Standard Motor Side Duct Metric100 149 199 249 299 349 399 100 149 199 249 299 349Blower Performance 10 TON Optional Motor Side Duct Metric Blower Performance 10 TON Optional Motor Side Duct Imperial100 149 199 249 299 349 399 448 498 548 Blower Performance 12-1/2 TON Side Duct Metric Blower Performance 12-1/2 TON Side Duct Imperial100 149 199 249 299 349 399 448 498 Blower Performance 7-1/2 TON Standard Motor Downshot Metric Blower Performance 7-1/2 TON Optional Motor Downshot Metric Blower Performance 10 TON Standard Motor Downshot ImperialBlower Performance 10 TON Standard Motor Downshot Metric 100 149 199 249 299Blower Performance 10 TON Optional Motor Downshot Imperial Blower Performance 10 TON Optional Motor Downshot MetricBlower Performance 12-1/2 TON Downshot Metric Blower Performance 12-1/2 TON Downshot Imperial100 149 199 249 299 349 399 448 Additional Static Resistance Imperial Cooling Only1 Economizer2 Electric Heat KW2Additional Static Resistance Metric Electric Heat Minimum Supply AIR ImperialElectric Heat Minimum Supply AIR Metric 12.5Indoor Blower Specifications Point Load WeightUnit Weight Model Location lbs. kg 090Detail B Unit ClearancesDetail C Detail D RightPredator Roof Curb Dimensions Bottom Duct Openings from Above Cooling Unit with GAS Heat Wiring Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram Unitary 5005 Norman Products York Group Drive 73069

DM120, DM150 specifications

The York DM120 and DM150 are advanced rooftop packaged units designed for commercial applications, offering high efficiency, reliability, and user-friendly features. These models are part of York's extensive range of HVAC solutions, aimed at meeting diverse heating, ventilation, and air conditioning needs.

One prominent feature of both the DM120 and DM150 is their streamlined, compact design, which allows for easy installation and fits seamlessly onto rooftops. These units are engineered to maximize space while ensuring high performance. With their robust construction, they are built to withstand harsh weather conditions, ensuring longevity and durability.

The DM120 is designed to provide a cooling capacity of up to 12 tons, whereas the DM150 can reach up to 15 tons. Both models utilize environmentally friendly refrigerants, which contribute to reducing the overall carbon footprint. This makes them a sustainable choice for businesses looking to enhance their environmental responsibility.

In terms of efficiency, both units are equipped with high-efficiency scroll compressors that optimize energy usage, lowering operational costs. They also feature advanced heat exchanger designs that enhance heat transfer efficiency, ensuring consistent indoor comfort while minimizing energy consumption.

User-friendly controls are another hallmark of the York DM120 and DM150. They come with an intuitive interface that allows for easy adjustments and monitoring of system performance. Advanced controls support integration with building management systems, enabling remote monitoring and control for enhanced operational efficiency.

The DM120 and DM150 also prioritize indoor air quality. They incorporate advanced filtration systems that capture airborne particles and improve ventilation, contributing to healthier indoor environments. Furthermore, these models come with variable-speed fans that adjust airflow based on current conditions, optimizing comfort while reducing noise levels.

The models are also designed for serviceability, allowing technicians easy access to critical components for maintenance. This feature not only prolongs the lifespan of the units but also minimizes downtime, keeping commercial spaces comfortable and operational.

In summary, the York DM120 and DM150 units represent an ideal balance of efficiency, technology, and reliability, making them suitable for various commercial applications. Their robust features, commitment to sustainability, and focus on user convenience make them a valuable investment for businesses seeking to improve their HVAC systems.