HEATING PERFORMANCE DATA

CONDENSING UNIT MODEL NO

THGD18S41S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

AHP18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING

ENTERING

 

450

 

 

600

 

 

750

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

19.7

1.6

3.7

21.0

1.6

3.9

22.3

1.6

4.2

60

 

 

 

 

 

 

 

 

 

 

70

18.3

1.6

3.3

19.6

1.6

3.5

20.9

1.6

3.8

 

 

 

 

 

 

 

 

 

 

 

 

80

16.8

1.7

2.9

18.1

1.7

3.2

19.5

1.7

3.4

 

 

 

 

 

 

 

 

 

 

 

 

60

16.4

1.5

3.3

17.6

1.5

3.5

18.8

1.5

3.7

47

 

 

 

 

 

 

 

 

 

 

70

15.2

1.5

3.0

16.4

1.5

3.2

17.6

1.5

3.3

 

 

 

 

 

 

 

 

 

 

 

 

80

14.0

1.5

2.7

15.2

1.6

2.8

16.4

1.6

3.0

 

 

 

 

 

 

 

 

 

 

 

 

60

14.9

1.4

3.1

16.2

1.4

3.3

17.5

1.5

3.5

40

 

 

 

 

 

 

 

 

 

 

70

12.4

1.4

2.5

14.3

1.5

2.9

16.3

1.5

3.2

 

 

 

 

 

 

 

 

 

 

 

 

80

9.9

1.5

2.0

12.5

1.5

2.4

15.0

1.6

2.8

 

 

 

 

 

 

 

 

 

 

 

 

60

10.3

1.3

2.2

11.5

1.4

2.4

12.7

1.5

2.5

30

 

 

 

 

 

 

 

 

 

 

70

11.5

1.3

2.5

12.7

1.4

2.7

14.0

1.4

2.9

 

 

 

 

 

 

 

 

 

 

 

 

80

12.6

1.3

2.8

13.9

1.4

3.0

15.2

1.4

3.2

 

 

 

 

 

 

 

 

 

 

 

 

60

7.6

1.2

1.9

7.8

1.3

1.8

7.9

1.4

1.7

17

 

 

 

 

 

 

 

 

 

 

70

8.2

1.2

2.0

8.5

1.3

2.0

8.8

1.3

2.0

 

 

 

 

 

 

 

 

 

 

 

 

80

8.8

1.2

2.2

9.2

1.2

2.2

9.7

1.3

2.2

 

 

 

 

 

 

 

 

 

 

 

 

60

6.1

1.1

1.6

6.7

1.2

1.6

7.3

1.3

1.7

10

 

 

 

 

 

 

 

 

 

 

70

6.2

1.1

1.6

7.1

1.2

1.7

8.0

1.3

1.8

 

 

 

 

 

 

 

 

 

 

 

 

80

6.2

1.1

1.6

7.4

1.2

1.8

8.6

1.3

2.0

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

FC/MC/PC18

1.00

1.00

1.00

FC/MC/PC24

1.03

1.04

0.99

HC18

1.00

1.00

1.00

HC30

1.02

1.02

0.99

HD24

0.97

0.96

1.02

AHP18

1.02

1.02

1.00

AV24

0.98

0.99

1.00

F4FP024

1.01

1.01

1.00

MV12B

FC/MC/PC18B

0.98

0.98

1.00

MA08B

FC/MC/PC18B

1.00

1.00

1.00

MA08B

FC/MC/PC24B

1.03

1.04

0.99

MV12B

FC/MC/PC24B

1.00

1.02

0.99

Variable Speed

Coil

MBH

KW

COP

Furnace

 

 

 

 

PV8*A12

FC/MC/PC18A

0.98

0.98

1.00

PV9*A12

FC/MC/PC18A

0.98

0.98

1.00

P(C,V)9*B12

FC/MC/PC18B

0.98

0.98

1.00

PV8*B16

FC/MC/PC18B

0.98

0.98

1.00

PV8*A12

FC/MC/PC24A

1.00

1.02

0.99

PV9*A12

FC/MC/PC24A

1.01

1.02

0.99

P(C,V)9*B12

FC/MC/PC24B

1.00

1.02

0.99

PV8*B16

FC/MC/PC24B

1.00

1.02

0.99

PV8*A12

HC18A

0.98

0.98

1.00

PV9*A12

HC18A

0.98

0.98

1.00

PV8*A12

HC30A

0.99

1.00

0.99

PV9*A12

HC30A

1.00

1.00

0.99

PV8*A12

HD24A

0.95

0.93

1.02

PV9*A12

HD24A

0.95

0.94

1.02

P(C,V)9*B12

HD24

0.95

0.94

1.02

PV8*B16

HD24

0.95

0.94

1.02

24

Johnson Controls Unitary Products

Image 24
Contents Listed Physical and Electrical Data ModelProcedures FootnotesUnit AIR Handler Cooling Rated NET MBH ModelSeer EER CFM SensSeer HP with AV / SV / F*FV Variable Speed Furnace Cooling Unit Model CFM Range Rated NET MBH SEER1Variable Speed Cooling Unit Model Furnace Model MODEL1 RatedSeer HP with Variable Speed FURNACES2 HC42C MC62C Unit AIR COIL1 ARI HEATING2 Model Handler HspfMBH COP STD Seer HP with MA Seer HP with MVMBH COP STD HP with AV / SV / F*FV Variable SpeedSeer HP with AHP Unit COIL1 ARI HEATING2 Model Unit Variable COIL1 ARI HEATING2 Speed Model Furnace MBH COP STD Seer HP with Variable Speed FURNACES3Unit Variable COIL1 ARI HEATING2 Speed Model Furnace MBH COP STDFurnace MBH COP STD Accessories Temperature CondensingEntering AIR FC/MC/PC24 FC/MC/PC30 FC/MC/PC32 FC/MC/PC35 FC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 FC/MC/PC37 FC/MC/PC43 FC/MC/PC48 1200 1400 1600 FC/MC/PC48 FC/MC/PC60 MA20D MC62D MV20D Entering Outdoor Unit Indoor CoilMBH COP 30.1 31.8 17.4 18.2 42.7 48.7 52.1 Johnson Controls Unitary Products York Drive Norman, OK

THGD18 THRU 60 specifications

The York THGD18 THRU 60 is a prominent addition to the realm of commercial air conditioning systems, designed specifically to provide high efficiency and reliability in various environments. This series offers a range from 18 to 60 tons, making it suitable for diverse applications, including restaurants, retail spaces, and office buildings.

One of the standout features of the York THGD18 THRU 60 is its Variable Speed Technology. This innovative approach allows the system to adjust its cooling performance in response to the surrounding conditions. By optimizing compressor speed, it maintains consistent temperatures while significantly reducing energy consumption. This not only leads to lower utility bills but also minimizes the carbon footprint, making it an ideal choice for environmentally conscious users.

In terms of durability, the THGD series is constructed with robust materials designed to withstand harsh weather conditions. This durability is complemented by the unit's ability to operate quietly, ensuring minimal disruption in noise-sensitive environments. The manufacturer has integrated advanced sound-dampening technology, allowing businesses to maintain a comfortable atmosphere.

The system's easy installation and maintenance further enhance its appeal. The THGD series comes with a user-friendly design that simplifies access to crucial components. This accessibility reduces downtime and maintenance costs, making it a practical option for facility managers.

A key technology embedded within the York THGD18 THRU 60 series is the advanced microprocessor control system. This intelligent feature allows for precise management of the unit's functions, enabling seamless integration with building management systems. The controls also include user-friendly interfaces that facilitate real-time monitoring and adjustments.

Moreover, the unit employs eco-friendly refrigerants that comply with stringent environmental regulations. This forward-thinking approach not only aligns with global sustainability efforts but also ensures compliance with future regulatory requirements.

In summary, the York THGD18 THRU 60 series stands out for its efficient variable speed operation, robust design, user-focused features, and commitment to sustainability. With an impressive range of capacities and highly adaptable technologies, it remains a top choice for businesses seeking reliable and efficient climate control solutions.