York TCGF24, TCGF60 warranty UC60C

Page 10

413432-YTG-A-0608

COOLING CAPACITY - With Variable Speed Furnaces (Continued)

UNIT MODEL

VARIABLE SPEED FURNACE MODEL

COIL

MODEL1

W

COOLING

RATED

Net MBH

SEER

EER

CFM

TOTAL

SENS.

 

 

14.5 SEER AC WITH VARIABLE SPEED FURNACES2

 

PV8*C20

FC/MC/PC36C

21

1200

34.0

24.6

15.25

12.75

 

PV9*A12

FC/MC/PC36A

14

1200

33.6

24.2

14.25

12.00

 

P(C,V)9*B12

FC/MC/PC36B

17

1200

33.8

24.4

14.75

12.25

 

P(C,V)9*C16

FC/MC/PC36C

21

1200

34.0

24.6

15.25

12.75

 

P(C,V)9*C20

FC/MC/PC36C

21

1200

34.0

24.6

15.00

12.75

 

PV8*A12

FC/MC/PC37A

14

1150

34.6

25.2

14.75

12.25

 

PV9*A12

FC/MC/PC37A

14

1100

34.0

24.4

14.75

12.25

 

PV8*B16

FC/MC/PC43B

17

1200

35.0

25.4

15.75

13.00

 

PV8*C16

FC/MC/PC43C

21

1200

35.0

25.6

15.75

13.00

 

PV8*C20

FC/MC/PC43C

21

1200

35.0

25.6

16.00

13.25

 

P(C,V)9*B12

FC/MC/PC43B

17

1200

34.6

25.4

15.00

12.50

 

P(C,V)9*C16

FC/MC/PC43C

21

1200

35.0

25.6

15.75

13.00

 

P(C,V)9*C20

FC/MC/PC43C

21

1200

34.8

25.4

15.50

13.00

 

PV8*C16

FC/MC/PC48C

21

1200

35.4

26.0

16.25

13.25

 

PV8*C20

FC/MC/PC48C

21

1200

35.4

26.0

16.25

13.25

 

P(C,V)9*C16

FC/MC/PC48C

21

1200

35.2

25.8

16.00

13.25

 

P(C,V)9*C20

FC/MC/PC48C

21

1200

35.2

25.8

15.75

13.00

 

P(C,V)9*D20

FC/MC/PC48D

24

1200

35.2

25.8

16.00

13.25

TCGF36S41S1

PV8*B16

HC36B

17

1200

34.2

25.0

15.25

12.75

 

 

 

 

 

 

 

 

P(C,V)9*B12

HC36B

17

1200

34.0

24.8

15.00

12.50

 

 

PV8*C16

HC42C

21

1200

35.0

25.6

15.75

13.25

 

PV8*C20

HC42C

21

1200

35.0

25.6

16.00

13.25

 

P(C,V)9*C16

HC42C

21

1200

35.0

25.6

15.75

13.00

 

P(C,V)9*C20

HC42C

21

1200

34.8

25.4

15.50

13.00

 

PV8*C16

HD48

21

1200

35.2

25.6

16.00

13.25

 

PV8*C20

HD48

21

1200

35.2

25.6

16.00

13.50

 

P(C,V)9*C16

HD48

21

1200

35.2

25.4

15.75

13.25

 

P(C,V)9*C20

HD48

21

1200

35.0

25.4

15.75

13.00

 

P(C,V)9*D20

HD48

24

1200

35.2

25.4

15.75

13.25

 

PV8*C20

FC/MC62D

21

1200

35.6

26.0

16.25

13.50

 

P(C,V)9*C16

FC/MC62D

21

1200

35.4

26.0

16.00

13.25

 

P(C,V)9*C20

FC/MC62D

21

1200

35.4

26.0

15.75

13.25

 

P(C,V)9*D20

FC/MC62D

24

1200

35.4

26.0

16.00

13.25

 

PV8*C16

UC60C

21

1200

33.8

24.2

15.50

12.75

 

PV8*C20

UC60C

21

1200

33.8

24.2

15.50

12.75

 

P(C,V)9*C16

UC60C

21

1200

33.8

24.2

15.25

12.75

 

P(C,V)9*C20

UC60C

21

1200

33.6

24.2

15.25

12.50

 

P(C,V)9*D20

UC60D

24

1200

33.8

24.2

15.25

12.75

 

PV8*B16

FC/MC/PC43B

17

1400

41.0

30.6

14.75

12.50

 

PV8*C20

FC/MC/PC43C

21

1400

41.0

30.8

14.75

12.75

 

P(C,V)9*C16

FC/MC/PC43C

21

1400

41.0

30.6

14.50

12.50

 

P(C,V)9*C20

FC/MC/PC43C

21

1350

41.0

30.8

15.00

12.75

 

PV8*C16

FC/MC/PC48C

21

1400

41.5

31.2

15.00

12.75

TCGF42S41S1

PV8*C20

FC/MC/PC48C

21

1400

41.5

31.2

15.25

12.75

P(C,V)9*C16

FC/MC/PC48C

21

1400

41.5

31.0

15.00

12.50

 

 

P(C,V)9*C20

FC/MC/PC48C

21

1350

41.5

31.2

15.25

12.75

 

P(C,V)9*D20

FC/MC/PC48D

24

1350

41.5

31.2

15.50

13.00

 

PV8*C16

FC/MC/PC60C

21

1400

41.5

31.2

15.00

12.75

 

PV8*C20

FC/MC/PC60C

21

1400

41.5

31.2

15.25

12.75

 

P(C,V)9*C16

FC/MC/PC60C

21

1400

41.0

31.0

14.75

12.50

For Notes See Page 9.

10

Johnson Controls Unitary Products

Image 10
Contents Listed Physical and Electrical Data ModelJohnson Controls Unitary Products Procedures FootnotesSeer EER Unit AIR HandlerCooling Rated NET MBH Model SensSeer AC with AV / SV / F*FV Variable Speed Seer AC with AHP / SHP / F*FPTotal Sens Cooling Capacity With Variable Speed Furnaces FC/MC/PC48D UC60C Cooling Unit Model Furnace Model MODEL1 Rated Variable SpeedSeer EER CFM Sound Power Ratings Condensing TemperatureAIR Conditioner Model no TCGF24S41S1 Indoor Coil Model no Entering AIRAir Handler Coil AIR Conditioner Model no TCGF30S41S1 Indoor Coil Model no HC36 HC42 HD36 HD48 UC30 1000 1200 1400 AV/SV48 FC/MC/PC42 FC/MC/PC43 FC/MC/PC60 FC/MC62 FC/MC/PC48 FC/MC62 AV/SV60 MV20D FC/MC60D MA20D FC/MC62D Johnson Controls Unitary Products York Drive Norman, OK

TCGF60, TCGF24 specifications

The York TCGF24 and TCGF60 are cutting-edge technologies designed to enhance the performance and efficiency of air conditioning systems. These units have gained significant popularity due to their advanced features, reliable performance, and energy-saving capabilities.

The TCGF24 and TCGF60 models are part of York's renowned line of commercial cooling products, designed primarily for larger spaces requiring consistent climate control. One of the standout features of these models is their powerful cooling capacity. The TCGF24 offers a cooling capacity of 24 tons, while the TCGF60 boasts an impressive 60 tons, making them suitable for a wide range of applications, from office buildings to industrial facilities.

Efficiency is a crucial consideration in today’s HVAC systems, and York has incorporated several technologies to ensure that both the TCGF24 and TCGF60 deliver optimal performance with reduced energy consumption. They utilize scroll compressors, which are known for their reliability and efficiency, helping to minimize energy costs. The units also come with advanced variable speed drive technology, allowing them to adjust motor speeds based on the cooling demands, further enhancing energy efficiency.

Both models are designed with user-friendliness in mind. They are equipped with intuitive control systems that simplify operation and monitoring. Building management systems can easily interface with these units, providing real-time data on performance and energy use. This feature allows facility managers to proactively manage the cooling system, ensuring that it operates at peak performance while adhering to sustainability goals.

In addition to performance and efficiency, durability is a key characteristic of the TCGF24 and TCGF60. Constructed with high-quality materials, these units are designed to withstand challenging environmental conditions. They come with robust insulation and weatherproof casings, ensuring longevity and reliable operation even in demanding situations.

The York TCGF24 and TCGF60 are also designed with environmental considerations in mind. They use refrigerants that have a lower global warming potential, aligning with modern regulations and sustainability initiatives. This focus on eco-friendly solutions further solidifies York's commitment to innovation in the HVAC industry.

In conclusion, the York TCGF24 and TCGF60 stand out as superior choices for commercial cooling solutions. With their advanced technologies, energy efficiency, user-friendly design, and enhanced durability, they offer reliable performance that meets the demands of today's commercial environments while also prioritizing environmental responsibility. These models exemplify York's dedication to providing innovative HVAC solutions that cater to both efficiency and sustainability.