York R-410A dimensions Physical Data, Mca, ARI Cooling Performance

Page 10

288429-YIM-A-0307

Table 5: Electrical Data (Continued)

 

 

 

Compressors

OD Fan

Supply

 

 

 

 

 

Max Fuse2/

Size

 

 

Motors

Blower

Electric Heat Option

 

MCA1

Breaker3

Model

Volt

 

(each)

 

 

(Tons)

 

 

(each)

Motor

 

 

 

 

(Amps)

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Amps)

 

 

 

RLA

LRA

 

MCC

FLA

FLA

Model

kW

Stages

Amps

 

 

 

 

 

 

 

 

 

 

None

-

-

-

29

35

 

 

 

 

 

 

 

 

 

2NH04500506

3.8/5

1

18.1/20.8

51.5/55

60/60

 

 

208/230-1-60

16.6

96

 

26

1.4

6.8

2NH04500706

5.6/7.5

2

27.1/31.3

62.8/68

70/70

 

 

 

 

 

 

 

 

 

2NP04501006

7.5/10

2

36.1/41.7

74.1/81

80/90

042

 

 

 

 

 

 

 

 

2NP04501506

11.3/15

2

54.2/62.5

96.7/107.1

100/110

DEX

 

 

 

 

 

 

 

None

-

-

-

25

30

(3.5)

 

 

 

 

 

 

 

 

208/230-3-60

13.4

88

 

21

1.4

6.8

2NP04501025

7.5/10

1

20.8/24.1

51/55

60/60

 

 

 

 

 

 

 

 

 

 

 

 

2NP04501525

11.3/15

1

31.3/36.1

64/70.1

70/80

 

 

 

 

 

 

 

 

 

None

-

-

-

15.2

20

 

 

460-3-60

6.1

44

 

10

0.8

6.8

2NP04501046

10

1

12

30.3

35

 

 

 

 

 

 

 

 

 

2NP04501546

15

1

18

37.8

40

 

 

 

 

 

 

 

 

 

None

-

-

-

34.9

45

 

 

 

 

 

 

 

 

 

2NP04501025

7.5/10

2

36.1/41.7

80/87

90/90

 

 

208/230-1-60

21.1

96

 

33

1.7

6.8

2NP04501525

11.3/15

2

54.2/62.5

102.6/113

110/125

 

 

 

 

 

 

 

 

 

2NP04502025

15/20

2

72.2/83.3

125.2/139

150/150

 

 

 

 

 

 

 

 

 

2NP04502525

18.8/25

2

90.3/104.2

147.7/165.1

150/175

 

 

 

 

 

 

 

 

 

None

-

-

-

25.3

35

048

 

 

 

 

 

 

 

 

2NP04501025

7.5/10

1

20.8/24.1

51.3/55.3

60/60

DEX

208/230-3-60

13.4

88

 

21

1.7

6.8

2NP04501525

11.3/15

1

31.3/36.1

64.3/70.4

70/80

(4.0)

 

 

 

 

 

 

 

 

 

2NP04502025

15/20

2

41.7/48.1

77.4/85.4

80/90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2NP04502525

18.8/25

2

52.1/60.1

90.4/100.4

100/110

 

 

 

 

 

 

 

 

 

None

-

-

-

15.8

20

 

 

 

 

 

 

 

 

 

2NP04501046

10

1

12

30.8

35

 

 

460-3-60

6.4

41

 

10

1.0

6.8

2NP04501546

15

1

18

38.4

40

 

 

 

 

 

 

 

 

 

2NH04502046

20

2

24.1

45.9

50

 

 

 

 

 

 

 

 

 

2NH04502546

25

2

30.1

53.4

60

 

 

 

 

 

 

 

 

 

None

-

-

-

42.8

60

 

 

 

 

 

 

 

 

 

2NH04501025

7.5/10

2

36.1/41.7

87.9/94.9

100/110

 

 

208/230-1-60

25.6

118

 

40

1.7

9.1

2NH04501525

11.3/15

2

54.2/62.5

110.5/120.9

125/125

 

 

 

 

 

 

 

 

 

2NH04502025

15/20

2

72.2/83.3

133.1/147

150/150

 

 

 

 

 

 

 

 

 

2NH04502525

18.8/25

2

90.3/104.2

155.6/173

175/175

 

 

 

 

 

 

 

 

 

None

-

-

-

32.8

40

060

 

 

 

 

 

 

 

 

2NH04501025

7.5/10

1

20.8/24.1

58.9/62.9

70/70

DEY

208/230-3-60

17.6

123

 

28

1.7

9.1

2NH04501525

11.3/15

1

31.3/36.1

71.9/77.9

80/80

(5.0)

 

 

 

 

 

 

 

 

 

2NH04502025

15/20

2

41.7/48.1

84.9/92.9

90/100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2NH04502525

18.8/25

2

52.1/60.1

98/108

100/110

 

 

 

 

 

 

 

 

 

None

-

-

-

21.4

30

 

 

 

 

 

 

 

 

 

2NP04501046

10

1

12

36.4

40

 

 

460-3-60

9.0

62

 

14

1.0

9.1

2NH04501546

15

1

18

43.9

45

 

 

 

 

 

 

 

 

 

2NH04502046

20

2

24.1

51.4

60

 

 

 

 

 

 

 

 

 

2NP04502546

25

2

30.1

58.9

60

1.Minimum Circuit Ampacity.

2.Maximum Over Current Protection per standard UL 1995.

3.Fuse or HACR circuit breaker size installed at factory or field installed.

Table 6: Physical Data

Component

 

 

Models

 

 

DEX024

DEX030

DEX036

DEX042

DEX048

DEY060

 

Nominal Tonnage

2.0

2.5

3.0

3.5

4.0

5.0

ARI COOLING PERFORMANCE

 

 

 

 

 

 

Gross Capacity @ ARI A point (Btu)

23.5

29.2

36.8

44.5

50.8

60.4

ARI net capacity (Btu)

23.2

28.6

36.0

43.5

49.0

58.5

EER

12.3

12.3

12.3

12.3

12.3

11.6

SEER

15

15

15

15

15

14.5

Nominal CFM

800

1000

1150

1400

1600

1750

System power (KW)

1.9

2.3

2.9

3.5

4.0

5.0

Refrigerant type

R-410a

R-410a

R-410a

R-410a

R-410a

R-410a

Refrigerant charge (lb-oz)

5-0

8-0

8-0

7-8

10-0

10-8

10

Unitary Products Group

Image 10
Contents DEY060 DEX024-048 Ton GeneralReference NomenclatureInspection Renewal PartsModel Unit Voltage Applied Voltage InstallationLimitations MinClearances Weight lbsLocation Rigging And Handling Point Load Location lbsUnit Size Dimensions Unit Accessory WeightsUnit Dimensions Front Unit ClearancesDimensions Front and Bottom Filters DuctworkRoof Curb Condensate DrainPower And Control Wiring Service AccessThermostat MCA1 RLA LRA MCC FLAMCA Physical DataARI Cooling Performance Compressors Side Duct Application Airflow PerformancePhasing CFMBottom Duct Application Additional Static Resistance Electric Heat Multipliers Indoor Blower SpecificationsElectric Heat Minimum Supply Air EffDEX036 Superheat Charging DEX024 Superheat ChargingDEX030 Superheat Charging DEX042 Superheat ChargingBlower Speed Selection Cooling Sequence Of Operations Electric Heat Limit Switch OperationOperation Heating Sequence Of OperationsThermostat Signals Three Phase Units Thermostat Signals Single Phase UnitsBoard Function Troubleshooting MaintenanceNormal Maintenance Typical Wiring Diagrams YIM-A-0307 YIM-A-0307 410A Quick Reference Guide Unitary 5005 Norman Products York Group Drive 73069
Related manuals
Manual 68 pages 3.65 Kb Manual 104 pages 7.39 Kb Manual 128 pages 30.42 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.