York R-410A dimensions Bottom Duct Application

Page 13

288429-YIM-A-0307

Table 7: Side Duct Application (Continued)

Size

 

 

 

Thermostat

Speed

 

 

External Static Pressure (Inch Water Gauge)

 

(Tons)

Model

Mode

Input

Tap

CFM

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

 

 

 

 

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

 

 

 

 

 

 

 

 

 

 

 

Y1

COOL-A

1050

184

216

248

280

313

346

380

414

449

 

 

 

Low

Y1

COOL-B

920

139

166

195

224

255

286

319

352

386

 

 

 

Y1

COOL-C

980

159

188

218

249

281

313

346

379

414

 

 

 

 

 

 

Cool

 

Y1

COOL-D

1120

211

245

279

313

348

382

417

452

486

 

 

 

Y1+Y2

COOL-A

1600

448

500

551

600

647

693

736

779

819

 

 

 

 

048

DEX

 

High

Y1+Y2

COOL-B

1400

338

383

426

468

509

549

589

627

664

(4.0)

 

Y1+Y2

COOL-C

1500

391

439

486

532

576

618

660

700

739

 

 

 

 

 

 

 

Y1+Y2

COOL-D

1700

508

565

620

672

723

772

818

863

905

 

 

 

 

W1

HEAT-A

1600

448

500

551

600

647

-

-

-

-

 

 

Heat

 

W1

HEAT-B

1440

359

405

449

493

535

-

-

-

-

 

 

 

W1

HEAT-C

1760

546

606

663

718

771

-

-

-

-

 

 

 

 

 

 

 

 

W1

HEAT-D

1600

448

500

551

600

647

-

-

-

-

 

 

 

 

Y1

COOL-A

1170

235

283

328

368

404

435

463

485

505

 

 

 

Low

Y1

COOL-B

1110

205

258

304

345

381

410

434

451

465

 

 

 

Y1

COOL-C

1210

255

301

344

384

420

454

483

509

533

 

 

 

 

 

 

Cool

 

Y1

COOL-D

1270

286

329

371

410

448

483

516

547

576

 

 

 

Y1+Y2

COOL-A

1750

559

608

658

710

762

815

870

925

981

 

 

 

 

060

DEY

 

High

Y1+Y2

COOL-B

1650

498

542

588

634

683

732

783

835

888

(5.0)

 

Y1+Y2

COOL-C

1800

590

643

696

750

805

860

916

973

1030

 

 

 

 

 

 

 

Y1+Y2

COOL-D

1900

654

715

775

836

895

955

1013

1072

-

 

 

 

 

W1

HEAT-A

1900

654

715

775

836

895

-

-

-

-

 

 

Heat

 

W1

HEAT-B

1975

703

772

839

904

968

-

-

-

-

 

 

 

W1

HEAT-C

2150

823

913

999

1079

1154

-

-

-

-

 

 

 

 

 

 

 

 

W1

HEAT-D

2070

767

847

923

997

1066

-

-

-

-

Table 8: Bottom Duct Application

Size

 

 

 

Thermostat

Speed

 

 

External Static Pressure (Inch Water Gauge)

 

(Tons)

Model

Mode

Input

Tap

CFM

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

 

 

 

 

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

 

 

 

 

 

 

 

 

 

 

 

Y1

COOL-A

600

57

74

91

108

126

143

161

179

197

 

 

 

Low

Y1

COOL-B

450

39

54

69

84

100

117

134

152

171

 

 

 

Y1

COOL-C

525

47

63

79

95

112

129

146

164

182

 

 

 

 

 

 

Cool

 

Y1

COOL-D

675

71

88

106

124

142

161

179

198

216

 

 

 

Y1+Y2

COOL-A

800

99

117

137

156

176

196

217

237

258

 

 

 

 

024

DEX

 

High

Y1+Y2

COOL-B

600

57

74

91

108

126

143

161

179

197

(2.0)

 

Y1+Y2

COOL-C

700

76

94

112

130

148

167

186

205

224

 

 

 

 

 

 

 

Y1+Y2

COOL-D

900

126

146

166

187

208

231

253

277

300

 

 

 

 

W1

HEAT-A

800

99

117

137

156

-

-

-

-

-

 

 

Heat

 

W1

HEAT-B

720

80

98

116

135

-

-

-

-

-

 

 

 

W1

HEAT-C

880

120

140

160

180

-

-

-

-

-

 

 

 

 

 

 

 

 

W1

HEAT-D

800

99

117

137

156

-

-

-

-

-

 

 

 

 

Y1

COOL-A

670

61

78

95

113

130

148

166

184

201

 

 

 

Low

Y1

COOL-B

620

54

70

87

104

121

138

156

173

191

 

 

 

Y1

COOL-C

720

70

88

106

124

142

160

178

197

215

 

 

 

 

 

 

Cool

 

Y1

COOL-D

770

81

99

118

136

155

174

193

213

232

 

 

 

Y1+Y2

COOL-A

1000

159

179

200

222

246

270

296

323

350

 

 

 

 

030

DEX

 

High

Y1+Y2

COOL-B

925

129

148

169

190

211

233

256

280

304

(2.5)

 

Y1+Y2

COOL-C

1075

194

214

236

260

285

312

341

371

403

 

 

 

 

 

 

 

Y1+Y2

COOL-D

1150

233

254

277

302

330

360

392

427

463

 

 

 

 

W1

HEAT-A

1000

159

179

200

222

-

-

-

-

-

 

 

Heat

 

W1

HEAT-B

900

120

139

159

180

-

-

-

-

-

 

 

 

W1

HEAT-C

1100

206

227

249

274

-

-

-

-

-

 

 

 

 

 

 

 

 

W1

HEAT-D

1000

159

179

200

222

-

-

-

-

-

 

 

 

 

Y1

COOL-A

900

120

139

159

180

201

222

244

267

291

 

 

 

Low

Y1

COOL-B

750

76

94

113

131

150

168

187

206

225

 

 

 

Y1

COOL-C

830

97

116

135

155

174

194

215

236

256

 

 

 

 

 

 

Cool

 

Y1

COOL-D

980

150

170

191

213

236

260

285

311

337

 

 

 

Y1+Y2

COOL-A

1200

261

283

306

333

362

394

429

467

507

 

 

 

 

036

DEX

 

High

Y1+Y2

COOL-B

1000

159

179

200

222

246

270

296

323

350

(3.0)

 

Y1+Y2

COOL-C

1100

206

227

249

274

300

328

357

389

422

 

 

 

 

 

 

 

Y1+Y2

COOL-D

1300

325

346

372

401

434

471

511

556

604

 

 

 

 

W1

HEAT-A

1200

261

283

306

333

-

-

-

-

-

 

 

Heat

 

W1

HEAT-B

1080

196

217

239

263

-

-

-

-

-

 

 

 

W1

HEAT-C

1275

308

330

355

383

-

-

-

-

-

 

 

 

 

 

 

 

 

W1

HEAT-D

1200

261

283

306

333

-

-

-

-

-

Unitary Products Group

13

Image 13
Contents General DEY060 DEX024-048 TonInspection NomenclatureReference Renewal PartsLimitations InstallationModel Unit Voltage Applied Voltage MinLocation Rigging And Handling Weight lbsClearances Point Load Location lbsUnit Dimensions Front Unit Accessory WeightsUnit Size Dimensions Unit ClearancesDimensions Front and Bottom Roof Curb DuctworkFilters Condensate DrainPower And Control Wiring Service AccessThermostat RLA LRA MCC FLA MCA1MCA Physical DataARI Cooling Performance Compressors Phasing Airflow PerformanceSide Duct Application CFMBottom Duct Application Additional Static Resistance Electric Heat Minimum Supply Air Indoor Blower SpecificationsElectric Heat Multipliers EffDEX030 Superheat Charging DEX024 Superheat ChargingDEX036 Superheat Charging DEX042 Superheat ChargingBlower Speed Selection Operation Electric Heat Limit Switch OperationCooling Sequence Of Operations Heating Sequence Of OperationsThermostat Signals Three Phase Units Thermostat Signals Single Phase UnitsBoard Function Troubleshooting MaintenanceNormal Maintenance Typical Wiring Diagrams YIM-A-0307 YIM-A-0307 Unitary 5005 Norman Products York Group Drive 73069 410A Quick Reference Guide
Related manuals
Manual 68 pages 3.65 Kb Manual 104 pages 7.39 Kb Manual 128 pages 30.42 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.