York WR 180 warranty 78.8 100

Page 40

262292-YTG-C-0707

TABLE 27: WR ELECTRICAL DATA - HIGH STATIC DRIVE MOTOR W/O POWERED CONVENIENCE OUTLET

 

 

COMPRESSORS

OD FAN

ID

CONV

 

HEATER OPTION

 

MIN.

MAX. FUSE/

MODEL

VOLTAGE

 

 

BLOWER

 

 

 

 

CIRCUIT

BRKR1

RLA

LRA

 

 

 

 

(TONNAGE)

MOTORS

MOTOR

OUTLET

MODEL

KW

STAGES

AMPS

AMPACITY

SIZE

 

EACH

EACH

FLA EACH

AMPS

 

 

FLA

 

 

 

 

(AMPS)

(AMPS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

-

78.8

100

 

208

 

 

 

 

 

E18

13.5

1

37.5

78.8

100

 

22.4

164

2.1

20.0

0.0

E36

27

2

74.9

118.7

125

 

 

 

 

 

 

 

E54

40.6

2

112.7

165.9

175

 

 

 

 

 

 

 

E72

54.1

2

150.2

175.2

200

 

 

 

 

 

 

 

None

-

-

-

78.8

100

 

230

 

 

 

 

 

E18

18.0

1

43.3

79.1

100

 

22.4

164

2.1

20.0

0.0

E36

36.0

2

86.6

133.3

150

 

 

 

 

 

 

 

E54

54.0

2

129.9

154.9

175

180

 

 

 

 

 

 

E72

72.0

2

173.2

198.2

225

(15)

 

 

 

 

 

 

None

-

-

-

39.3

50

 

460

 

 

 

 

 

E18

18.0

1

21.7

39.6

50

 

10.9

100

1.2

10.0

0.0

E36

36.0

2

43.3

66.6

70

 

 

 

 

 

 

 

E54

54.0

2

65.0

77.5

90

 

 

 

 

 

 

 

E72

72.0

2

86.6

99.1

110

 

 

 

 

 

 

 

None

-

-

-

29.8

35

 

575

 

 

 

 

 

E18

18.0

1

17.3

31.0

35

 

8.3

78

0.9

7.5

0.0

E36

36.0

2

34.6

52.7

60

 

 

 

 

 

 

 

E54

54.0

2

52.0

61.3

70

 

 

 

 

 

 

 

E72

72.0

2

69.3

78.7

90

 

 

 

 

 

 

 

None

-

-

-

118.1

150

 

208

 

 

 

 

 

E18

13.5

1

37.5

118.1

150

 

30.1

225

2.4

38.6

0.0

E36

27

2

74.9

141.9

150

 

 

 

 

 

 

 

E54

40.6

2

112.7

189.1

200

 

 

 

 

 

 

 

E72

54.1

2

150.2

198.4

225

 

 

 

 

 

 

 

None

-

-

-

118.1

150

 

230

 

 

 

 

 

E18

18.0

1

43.3

118.1

150

 

30.1

225

2.4

38.6

0.0

E36

36.0

2

86.6

156.5

175

 

 

 

 

 

 

 

E54

54.0

2

129.9

178.2

200

240

 

 

 

 

 

 

E72

72.0

2

173.2

221.5

250

(20)

 

 

 

 

 

 

None

-

-

-

58.7

70

 

460

 

 

 

 

 

E18

18.0

1

21.7

58.7

70

 

15.5

114

0.9

19.3

0.0

E36

36.0

2

43.3

78.3

80

 

 

 

 

 

 

 

E54

54.0

2

65.0

89.1

100

 

 

 

 

 

 

 

E72

72.0

2

86.6

110.7

125

 

 

 

 

 

 

 

None

-

-

-

46.9

60

 

575

 

 

 

 

 

E18

18.0

1

17.3

46.9

60

 

12.1

80

0.6

16.2

0.0

E36

36.0

2

34.6

63.6

70

 

 

 

 

 

 

 

E54

54.0

2

52.0

72.2

80

 

 

 

 

 

 

 

E72

72.0

2

69.3

89.5

100

 

 

 

 

 

 

 

None

-

-

-

143.4

175

 

208

 

 

 

 

 

E18

13.5

1

37.5

143.4

175

 

42.3

245

2.4

38.6

0.0

E36

27

2

74.9

143.4

175

 

 

 

 

 

 

 

E54

40.6

2

112.7

189.1

200

 

 

 

 

 

 

 

E72

54.1

2

150.2

198.4

225

 

 

 

 

 

 

 

None

-

-

-

143.4

175

 

230

 

 

 

 

 

E18

18.0

1

43.3

143.4

175

 

42.3

245

2.4

38.6

0.0

E36

36.0

2

86.6

156.5

175

 

 

 

 

 

 

 

E54

54.0

2

129.9

178.2

200

300

 

 

 

 

 

 

E72

72.0

2

173.2

221.5

250

(25)

 

 

 

 

 

 

None

-

-

-

62.9

80

 

460

 

 

 

 

 

E18

18.0

1

21.7

62.9

80

 

17.6

125

0.9

19.3

0.0

E36

36.0

2

43.3

78.3

80

 

 

 

 

 

 

 

E54

54.0

2

65.0

89.1

100

 

 

 

 

 

 

 

E72

72.0

2

86.6

110.7

125

 

 

 

 

 

 

 

None

-

-

-

51.7

60

 

575

 

 

 

 

 

E18

18.0

1

17.3

51.7

60

 

14.5

100

0.6

16.2

0.0

E36

36.0

2

34.6

63.6

70

 

 

 

 

 

 

 

E54

54.0

2

52.0

72.2

80

 

 

 

 

 

 

 

E72

72.0

2

69.3

89.5

100

NOTE 1: HACR Type per NEC.

 

VOLTAGE LIMITATIONS

 

 

 

 

ELECTRIC HEAT CORRECTION FACTORS

 

POWER SUPPLY

 

 

VOLTAGE

NOMINAL VOLTAGE

 

VOLTAGE

kW CAP. MULTIPLIER

VOLTAGE

 

 

MIN.

 

MAX.

208

 

208

1.00

208/230-3-60

 

187

 

253

240

 

230

0.92

LIMITATIONS1

460-3-60

 

414

 

506

480

 

460

0.92

 

575-3-60

 

518

 

630

600

 

575

0.92

1.Utilization Range “A” in accordance with ARI Standard 110.

40

Unitary Products Group

Image 40
Contents Warranty GAS/ELECTRIC Single Package AIR ConditionersTable of Contents Ton Sunline MagnaDRY Model Number Nomenclature Features Normal Mode Unit CutawayAlternate Mode Reheat Control BoardReheat Controls Part FACTORY-INSTALLED Options Unitary Products Group FIELD-INSTALLED Accessories Capacity Ratings ARI Sound Power RATING1GAS Heat Ratings Cooling Capacities for WR180 MBH104 151 16.9 142 118 101 147 15.2 Cooling Capacities for WR240 240 21.3 101 225 23.1 100 5000 221 21.0 140 Cooling Capacities for WR300 281 26.6 128 Cooling Capacities for WR180 Alternate Reheat Mode Cooling Capacities for WR240 Alternate Reheat Mode Cooling Capacities for WR300 Alternate Reheat Mode EV+U Lbs/Hr Lbs/Hr Altitude Correction Factors AIR Temp Altitude Feet$OWLWXGH7HPSHUDWXUH&RQYHUVLRQDFWRU ESP CFM RPM BHP Scfm Scfm Scfm Scfm Ton Standard Drive, Gas Heat, Bottom Connection VP68 x BK100 HP motor 10 HP motor 7.5 HP motor YTG-C-0707 12000 11000 YTG-C-0707 Ton High Static Drive, Cooling Only, Bottom Duct Connection Ton High Static Drive, Gas Heat, Bottom Duct Connection Blower Motor and Drive Data Power Exhaust PerformanceStatic RESISTANCES1 BRKR1 78.8 100 97.3 125 E18 13.5 37.5 86.5 100 88.8 107.3 125 E18 13.5 37.5 Physical Data Models WR180 WR240 WR300Hole Rear View Dimensions Unit Dimensions WR180, 240 & 300 Rainhood Minimum ClearancesUnit Center of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Field Wiring Indoor Evaporator FAN Assembly Unit CabinetOutdoor Condenser FAN Assembly Refrigerant ComponentsUnit Controls GAS Heating Section WR***N ModelsUnit Operating Characteristics Other PRE-ENGINEERED Accessories AvailableElectrical Requirements Standard Limited WarrantiesOther Factory Installed Options LOW Static Drive WR240 & WR300 only

WR 180 specifications

The York WR 180 is a state-of-the-art water-cooled chiller, renowned for its efficiency, flexibility, and reliability in various applications. Designed specifically for commercial and industrial use, the WR 180 stands out as an ideal solution for facilities requiring effective climate control, such as hotels, hospitals, shopping malls, and large office buildings.

One of the primary features of the York WR 180 is its advanced chiller design, which incorporates variable speed technology. This allows the unit to adjust its cooling capacity based on the actual load demands of the building, leading to significant energy savings. By operating at variable speeds instead of a fixed rate, the chiller minimizes energy consumption during lower demand periods while maintaining optimal performance during peak loads.

The WR 180 also employs a reliable and efficient centrifugal compressor, which contributes to its high energy efficiency ratio (EER). This compressor is designed to provide robust cooling while operating quietly, making it suitable for environments where noise reduction is essential. Additionally, the unit features a microprocessor-based control system that offers sophisticated monitoring and control capabilities, allowing operators to fine-tune performance and enhance reliability.

Another notable characteristic of the York WR 180 is its environmentally friendly refrigerant options. The chiller can operate with refrigerants that have a low global warming potential (GWP), aligning with international regulations and environmental sustainability goals. This commitment to eco-friendly designs not only helps reduce the carbon footprint but also ensures compliance with industry standards.

In terms of installation and maintenance, the WR 180 is designed for user-friendliness. Its modular design simplifies transport and installation in various spaces, while easy-access components facilitate routine maintenance. The chiller also offers various connectivity options, enabling integration with building management systems for real-time monitoring and control.

Overall, the York WR 180 combines innovative design, cutting-edge technology, and eco-friendly practices, making it a top choice for industries seeking efficient and sustainable cooling solutions. Its impressive features, coupled with strong operational flexibility, position the WR 180 as a leader in the chiller market.