York WR 180 warranty Ton High Static Drive, Cooling Only, Bottom Duct Connection

Page 36

262292-YTG-C-0707

TABLE 21: WR300 BLOWER PERFORMANCE - 25 TON HIGH STATIC DRIVE (COOLING ONLY) DOWNFLOW

Blower Performance (Downflow Discharge)

ESP

CFM

RPM

KW

BHP

CFM

RPM

KW

BHP

CFM

RPM

KW

BHP

CFM

RPM

KW

BHP

CFM

RPM

KW

BHP

CFM

RPM

KW

BHP

0.4

11830

1216

12.80

15.62

11374

1181

11.51

14.05

11030

1146

10.55

12.87

10572

1111

9.50

11.59

10220

1075

8.67

10.58

9928

1041

7.91

9.65

0.6

11546

1217

12.31

15.02

11079

1181

11.12

13.57

10600

1147

10.00

12.20

10231

1112

9.11

11.12

9885

1076

8.28

10.10

9575

1040

7.52

9.18

0.8

11239

1217

11.87

14.49

10770

1182

10.79

13.17

10232

1147

9.63

11.75

9912

1112

8.87

10.82

9537

1077

7.94

9.69

9207

1042

7.08

8.63

1.0

10923

1218

11.48

14.01

10388

1183

10.25

12.51

9919

1148

9.28

11.32

9607

1114

8.39

10.24

9171

1078

7.54

9.20

8833

1043

6.72

8.21

1.2

10618

1219

11.14

13.60

10054

1185

9.82

11.98

9591

1149

8.93

10.90

9201

1114

8.01

9.77

8799

1079

7.18

8.76

8439

1044

6.39

7.80

1.4

10302

1221

10.66

13.01

9703

1186

9.42

11.50

9228

1150

8.48

10.35

8793

1115

7.55

9.21

8407

1080

6.76

8.25

7996

1044

6.03

7.36

1.6

9958

1222

10.21

12.45

9346

1186

9.05

11.04

8861

1151

8.12

9.91

8394

1116

7.13

8.69

7992

1081

6.42

7.84

7565

1045

5.66

6.90

1.8

9605

1223

9.71

11.85

9032

1187

8.61

10.51

8484

1153

7.58

9.25

8008

1117

6.86

8.37

7513

1081

6.01

7.33

7045

1047

5.20

6.35

2.0

9219

1225

9.25

11.29

8638

1189

8.18

9.98

8092

1154

7.26

8.86

7624

1118

6.37

7.77

6987

1082

5.53

6.75

-

-

-

-

2.2

8796

1226

8.82

10.76

8250

1190

7.78

9.49

7637

1155

6.67

8.14

7134

1119

5.99

7.31

-

-

-

-

-

-

-

-

2.4

8287

1227

8.19

10.00

7791

1191

7.26

8.86

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2.6

7782

1229

7.98

9.74

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

1

turn

 

 

2 turns

 

 

3 turns

 

 

4 turns

 

 

5 turns

 

 

6 turns

 

15 HP motor 10 HP motor 7.5 HP motor

 

 

 

 

25-Ton High Static Drive, Cooling Only, Bottom Duct Connection

 

 

 

 

13000

 

 

 

 

 

1VP71 & 1B5V94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12000

1 Turn

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Turns

 

 

 

 

 

 

 

 

 

 

 

 

11000

3 Turns

 

 

 

 

 

 

 

 

 

 

 

 

4 Turns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 Turns

 

 

 

 

 

 

 

 

 

 

 

SCFM

10000

6 Turns

 

 

 

 

 

 

 

 

 

 

 

9000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8000

 

 

 

 

 

 

 

 

 

 

 

 

 

7000

 

 

 

 

 

 

 

 

 

 

 

 

 

6000

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

2.2

2.4

2.6

 

 

 

 

 

 

 

External Static ("WC)

 

 

 

 

 

 

36

Unitary Products Group

Image 36
Contents Warranty GAS/ELECTRIC Single Package AIR ConditionersTable of Contents Ton Sunline MagnaDRY Model Number Nomenclature Features Normal Mode Unit CutawayAlternate Mode Reheat Control BoardReheat Controls Part FACTORY-INSTALLED Options Unitary Products Group FIELD-INSTALLED Accessories Sound Power RATING1 Capacity Ratings ARIGAS Heat Ratings Cooling Capacities for WR180 MBH104 151 16.9 142 118 101 147 15.2 Cooling Capacities for WR240 240 21.3 101 225 23.1 100 5000 221 21.0 140 Cooling Capacities for WR300 281 26.6 128 Cooling Capacities for WR180 Alternate Reheat Mode Cooling Capacities for WR240 Alternate Reheat Mode Cooling Capacities for WR300 Alternate Reheat Mode EV+U Lbs/Hr Lbs/Hr Altitude Correction Factors AIR Temp Altitude Feet$OWLWXGH7HPSHUDWXUH&RQYHUVLRQDFWRU ESP CFM RPM BHP Scfm Scfm Scfm Scfm Ton Standard Drive, Gas Heat, Bottom Connection VP68 x BK100 HP motor 10 HP motor 7.5 HP motor YTG-C-0707 12000 11000 YTG-C-0707 Ton High Static Drive, Cooling Only, Bottom Duct Connection Ton High Static Drive, Gas Heat, Bottom Duct Connection Power Exhaust Performance Blower Motor and Drive DataStatic RESISTANCES1 BRKR1 78.8 100 97.3 125 E18 13.5 37.5 86.5 100 88.8 107.3 125 E18 13.5 37.5 Physical Data Models WR180 WR240 WR300Hole Rear View Dimensions Unit Dimensions WR180, 240 & 300 Rainhood Minimum ClearancesUnit Center of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Field Wiring Indoor Evaporator FAN Assembly Unit CabinetOutdoor Condenser FAN Assembly Refrigerant ComponentsUnit Controls GAS Heating Section WR***N ModelsUnit Operating Characteristics Other PRE-ENGINEERED Accessories AvailableElectrical Requirements Standard Limited WarrantiesOther Factory Installed Options LOW Static Drive WR240 & WR300 only

WR 180 specifications

The York WR 180 is a state-of-the-art water-cooled chiller, renowned for its efficiency, flexibility, and reliability in various applications. Designed specifically for commercial and industrial use, the WR 180 stands out as an ideal solution for facilities requiring effective climate control, such as hotels, hospitals, shopping malls, and large office buildings.

One of the primary features of the York WR 180 is its advanced chiller design, which incorporates variable speed technology. This allows the unit to adjust its cooling capacity based on the actual load demands of the building, leading to significant energy savings. By operating at variable speeds instead of a fixed rate, the chiller minimizes energy consumption during lower demand periods while maintaining optimal performance during peak loads.

The WR 180 also employs a reliable and efficient centrifugal compressor, which contributes to its high energy efficiency ratio (EER). This compressor is designed to provide robust cooling while operating quietly, making it suitable for environments where noise reduction is essential. Additionally, the unit features a microprocessor-based control system that offers sophisticated monitoring and control capabilities, allowing operators to fine-tune performance and enhance reliability.

Another notable characteristic of the York WR 180 is its environmentally friendly refrigerant options. The chiller can operate with refrigerants that have a low global warming potential (GWP), aligning with international regulations and environmental sustainability goals. This commitment to eco-friendly designs not only helps reduce the carbon footprint but also ensures compliance with industry standards.

In terms of installation and maintenance, the WR 180 is designed for user-friendliness. Its modular design simplifies transport and installation in various spaces, while easy-access components facilitate routine maintenance. The chiller also offers various connectivity options, enabling integration with building management systems for real-time monitoring and control.

Overall, the York WR 180 combines innovative design, cutting-edge technology, and eco-friendly practices, making it a top choice for industries seeking efficient and sustainable cooling solutions. Its impressive features, coupled with strong operational flexibility, position the WR 180 as a leader in the chiller market.