York WR 180 warranty Unit Roof Curb Dimensions

Page 51

262292-YTG-C-0707

25-1/4"

FIGURE 18:UNIT ROOF CURB DIMENSIONS

NOTE: Ducts can be installed into the curb from the roof. All electrical and gas line connections can be made inside the curb.

FIGURE 19:ROOF CURB DUCT OPENINGS DIMENSION

1.The 2” space between the ducts allows for “jumping” an existing roof joist.

2.The 58-1/2” overall dimension of the ducts allows ductwork penetration between roof joists that are spaced on 72” centers.

´;´:,'(*$6.(7,1*)25&85%³ )5$0($1'$//'8&76833257685)$&(6

81,7%$6(

:22'1$,/(5

81,7%$6(5$,/6

´

³0,1$%29(),1,6+('522) &2817(5)/$6+,1*

&85%)5$0(&$1¶7675,3

,168/$7,21$1'522),1*0$7(5,$/

,168/$7,21

522)'(&.$1'68332576758&785(

FIGURE 20:CUT AWAY OF ROOF CURB

Unitary Products Group

51

Image 51
Contents GAS/ELECTRIC Single Package AIR Conditioners WarrantyTable of Contents Ton Sunline MagnaDRY Model Number Nomenclature Features Unit Cutaway Normal ModeReheat Control Board Alternate ModeReheat Controls Part FACTORY-INSTALLED Options Unitary Products Group FIELD-INSTALLED Accessories Sound Power RATING1 Capacity Ratings ARIGAS Heat Ratings MBH Cooling Capacities for WR180104 151 16.9 142 118 101 147 15.2 Cooling Capacities for WR240 240 21.3 101 225 23.1 100 5000 221 21.0 140 Cooling Capacities for WR300 281 26.6 128 Cooling Capacities for WR180 Alternate Reheat Mode Cooling Capacities for WR240 Alternate Reheat Mode Cooling Capacities for WR300 Alternate Reheat Mode EV+U Lbs/Hr Lbs/Hr AIR Temp Altitude Feet Altitude Correction Factors$OWLWXGH7HPSHUDWXUH&RQYHUVLRQDFWRU ESP CFM RPM BHP Scfm Scfm Scfm Scfm Ton Standard Drive, Gas Heat, Bottom Connection VP68 x BK100 HP motor 10 HP motor 7.5 HP motor YTG-C-0707 12000 11000 YTG-C-0707 Ton High Static Drive, Cooling Only, Bottom Duct Connection Ton High Static Drive, Gas Heat, Bottom Duct Connection Power Exhaust Performance Blower Motor and Drive DataStatic RESISTANCES1 BRKR1 78.8 100 97.3 125 E18 13.5 37.5 86.5 100 88.8 107.3 125 E18 13.5 37.5 WR180 WR240 WR300 Physical Data ModelsHole Rear View Dimensions Minimum Clearances Unit Dimensions WR180, 240 & 300 RainhoodUnit Center of Gravity Four and SIX Point Loads Unit Roof Curb Dimensions Typical Field Wiring Unit Cabinet Indoor Evaporator FAN AssemblyGAS Heating Section WR***N Models Outdoor Condenser FAN AssemblyRefrigerant Components Unit ControlsStandard Limited Warranties Unit Operating CharacteristicsOther PRE-ENGINEERED Accessories Available Electrical RequirementsLOW Static Drive WR240 & WR300 only Other Factory Installed Options

WR 180 specifications

The York WR 180 is a state-of-the-art water-cooled chiller, renowned for its efficiency, flexibility, and reliability in various applications. Designed specifically for commercial and industrial use, the WR 180 stands out as an ideal solution for facilities requiring effective climate control, such as hotels, hospitals, shopping malls, and large office buildings.

One of the primary features of the York WR 180 is its advanced chiller design, which incorporates variable speed technology. This allows the unit to adjust its cooling capacity based on the actual load demands of the building, leading to significant energy savings. By operating at variable speeds instead of a fixed rate, the chiller minimizes energy consumption during lower demand periods while maintaining optimal performance during peak loads.

The WR 180 also employs a reliable and efficient centrifugal compressor, which contributes to its high energy efficiency ratio (EER). This compressor is designed to provide robust cooling while operating quietly, making it suitable for environments where noise reduction is essential. Additionally, the unit features a microprocessor-based control system that offers sophisticated monitoring and control capabilities, allowing operators to fine-tune performance and enhance reliability.

Another notable characteristic of the York WR 180 is its environmentally friendly refrigerant options. The chiller can operate with refrigerants that have a low global warming potential (GWP), aligning with international regulations and environmental sustainability goals. This commitment to eco-friendly designs not only helps reduce the carbon footprint but also ensures compliance with industry standards.

In terms of installation and maintenance, the WR 180 is designed for user-friendliness. Its modular design simplifies transport and installation in various spaces, while easy-access components facilitate routine maintenance. The chiller also offers various connectivity options, enabling integration with building management systems for real-time monitoring and control.

Overall, the York WR 180 combines innovative design, cutting-edge technology, and eco-friendly practices, making it a top choice for industries seeking efficient and sustainable cooling solutions. Its impressive features, coupled with strong operational flexibility, position the WR 180 as a leader in the chiller market.