COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

YCJD42S41S1(H)

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

FC/MC/PC43

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

1200

 

 

 

 

1400

 

 

 

 

1600

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

44.4

45.5

43.6

47.0

48.5

45.9

46.5

45.0

48.5

49.8

47.5

47.5

46.5

50.1

51.1

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

41.5

35.6

29.7

28.7

21.5

42.9

37.5

31.4

30.2

22.9

44.4

39.4

33.2

31.7

24.3

 

KW

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.6

2.5

2.5

2.5

2.5

2.6

 

T.C.

42.3

42.9

41.2

45.1

46.6

44.2

44.3

42.7

46.6

47.9

46.0

45.7

44.2

48.1

49.1

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

39.4

35.2

29.2

28.5

21.3

41.1

37.4

31.1

30.1

22.4

42.9

39.7

33.0

31.8

23.6

 

KW

2.7

2.7

2.7

2.8

2.8

2.7

2.7

2.7

2.8

2.8

2.8

2.8

2.8

2.8

2.9

 

T.C.

40.2

40.3

38.9

43.3

44.6

42.4

42.1

40.4

44.7

45.9

44.6

43.9

41.9

46.0

47.2

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

37.2

34.7

28.7

28.2

21.2

39.3

37.3

30.8

30.0

22.0

41.5

40.0

32.9

31.8

22.9

 

KW

3.0

3.0

3.0

3.0

3.1

3.0

3.0

3.0

3.1

3.1

3.0

3.0

3.0

3.1

3.1

 

T.C.

38.2

37.7

36.5

41.5

42.7

40.7

39.9

38.0

42.0

44.0

43.2

42.1

39.6

43.9

45.3

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

35.0

34.3

28.1

28.0

21.0

37.5

37.3

30.5

29.4

21.6

40.0

40.3

32.8

31.9

22.2

 

KW

3.2

3.2

3.2

3.3

3.4

3.3

3.3

3.3

3.3

3.4

3.3

3.3

3.3

3.4

3.4

 

T.C.

35.3

34.7

32.8

37.4

38.7

37.5

36.7

34.2

38.6

39.8

39.8

38.8

35.6

39.8

40.9

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.3

32.1

26.5

26.4

19.6

34.5

34.5

28.8

28.4

20.4

36.7

37.0

31.1

30.5

21.2

 

KW

3.5

3.5

3.5

3.6

3.7

3.5

3.5

3.5

3.6

3.7

3.6

3.6

3.5

3.6

3.7

 

T.C.

32.4

31.7

29.2

33.4

34.8

34.5

33.6

30.5

34.6

35.7

36.5

35.5

31.8

35.7

36.7

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

29.7

30.0

25.0

24.9

18.2

31.6

31.9

27.2

27.0

19.3

33.5

33.8

29.4

29.1

20.3

 

KW

3.7

3.7

3.7

3.8

4.0

3.8

3.8

3.7

3.8

4.0

3.8

3.8

3.7

3.9

4.0

 

T.C.

29.6

28.8

25.6

29.4

30.9

31.4

30.5

26.8

30.5

31.7

33.2

32.2

28.0

31.7

32.5

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

27.1

27.9

23.5

23.4

16.8

28.7

29.3

25.6

25.6

18.1

30.2

30.6

27.6

27.8

19.4

 

KW

4.0

4.0

3.9

4.0

4.2

4.0

4.0

4.0

4.1

4.3

4.1

4.1

4.0

4.1

4.3

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

FC/MC/PC48

1.00

1.00

1.00

HC42

1.00

1.00

1.00

UC48

1.00

1.00

1.00

AHP42

0.97

1.00

0.97

MV16C

FC/MC43C

1.00

1.02

0.91

MA16C

FC/MC43C

1.00

1.00

1.00

MV16C

FC/MC48C

1.00

1.02

0.91

MV20D

FC/MC48D

1.00

1.02

0.91

MA14D

FC/MC48D

1.00

1.00

1.00

MA16C

FC/MC48C

1.00

1.00

1.00

F5FP048

1.00

1.00

1.00

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

PV8*B16

FC/MC/PC43B

1.00

1.01

0.91

PV8*C20

FC/MC/PC43C

1.00

1.02

0.91

P(C,V)9*C16

FC/MC/PC43C

1.00

1.01

1.00

P(C,V)9*C20

FC/MC/PC43C

1.00

1.02

0.91

PV8*C16

FC/MC/PC48C

1.00

1.01

0.91

PV8*C20

FC/MC/PC48C

1.00

1.02

0.91

P(C,V)9*C16

FC/MC/PC48C

1.00

1.01

1.00

P(C,V)9*C20

FC/MC/PC48C

1.00

1.02

0.91

P(C,V)9*D20

FC/MC/PC48D

1.00

1.02

0.91

PV8*C16

HC42

1.00

1.01

0.91

PV8*C20

HC42

1.00

1.02

0.91

P(C,V)9*C16

HC42

1.00

1.01

1.00

P(C,V)9*C20

HC42

1.00

1.02

0.91

Johnson Controls Unitary Products

15

Image 15
Contents Listed YCJD18 YCJD24 YCJD30 YCJD36 YCJD42 YCJD48 YCJD60 ModelFC/MC/PC35B3X FC/MC/PC/UC18A3XFC/MC/PC/UC18B3X FC/MC/PC32A3XFootnotes ProceduresSens Unit AIR HandlerCooling Rated NET MBH Model Seer EER CFMAHP42 AHP18AHP30 AHP36Cooling Unit Model CFM Range Rated NET MBH SEER1 FurnaceVariable Speed Cooling Unit Model Furnace Model MODEL1 RatedSeer AC with Variable Speed FURNACES2 FC/MC/PC48D FC/PC60CFC/MC/PC60D TBD AccessoriesCondensing TemperatureAIR Conditioner Model no Indoor Coil Model noMV12B FC/MC36B MA08B FC/MC35B FC/MC43B FC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 AHP30 AHP36MV12B FC/MC35B MV16C FC/MC35C MA12B FC/MC43B FC/MC43C Indoor Coil Model no FC/MC/PC43 Condensing FC/MC/PC43 FC/MC/PC48AHP36 AHP42 AHP42 MV16C FC/MC43C MA16C FC/MC48C MV20D FC/MC48D MA14D Indoor Coil Model no FC/MC/PC48 Condensing FC/MC/PC/UC60D Indoor Coil Model no FC/MC/PC60 CondensingAHP/SHP60 AV/SV60 MV20D FC/MC60D MA20D FC/MC62D FC/PC/UC60CJohnson Controls Unitary Products York Drive Norman, OK