York BHP024 manual Cooling Capacities 2-1/2 TON BHP030

Page 7

036-21528-007-A-1205

TABLE 4: COOLING CAPACITIES - 2-1/2 TON (BHP030)

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE OF AIR ON INDOOR COIL

 

 

 

TEMPERATURE AIR ON

 

 

1000 CFM

 

 

1125 CFM

 

 

OUTDOOR COIL

 

 

 

 

 

WB °F

 

 

 

WB °F

 

 

 

 

 

 

 

 

 

72

67

 

62

57

72

67

 

62

57

 

 

 

NET CAP. MBH

 

34.1

31.5

 

28.4

29.9

35.4

32.7

 

29.5

31.0

 

 

POWER INPUT kW

 

2.52

2.48

 

2.44

2.43

2.64

2.58

 

2.54

2.53

 

CapacitySensible

 

 

 

 

 

86

23.9

29.8

 

28.4

29.9

25.7

31.8

 

29.5

31.0

 

MBH

 

DryEntering

°FBulb

 

83

21.0

26.9

 

28.4

29.9

22.4

28.5

 

29.5

31.0

 

 

 

 

 

 

 

 

 

85 °F

 

1

 

 

 

 

80

18.1

23.9

 

27.9

29.6

19.0

25.2

 

29.2

30.8

 

 

 

 

 

 

 

77

15.2

21.0

 

24.9

26.6

15.7

21.9

 

25.9

27.5

 

 

 

 

 

 

 

74

12.3

18.1

 

22.0

23.7

12.4

18.5

 

22.6

24.2

 

 

 

 

 

 

 

71

#N/A

15.2

 

19.1

20.8

#N/A

15.2

 

19.2

20.9

 

 

 

 

 

 

 

68

#N/A

12.3

 

16.2

17.9

#N/A

11.9

 

15.9

17.5

 

 

 

NET

CAP. MBH

 

 

32.6

29.4

 

26.8

28.9

33.7

30.4

 

27.7

29.8

 

 

POWER INPUT kW

 

2.83

2.81

 

2.71

2.70

2.93

2.91

 

2.81

2.79

 

CapacitySensible

 

 

 

 

 

86

22.8

28.2

 

26.8

28.9

25.0

29.7

 

27.7

29.8

 

MBH

 

DryEntering

°FBulb

 

83

19.9

25.3

 

26.8

28.9

21.7

27.5

 

27.7

29.8

 

 

 

 

 

 

 

 

 

95 °F

 

1

 

 

 

 

80

17.0

22.4

 

26.6

28.3

18.3

24.2

 

27.5

29.5

 

 

 

 

 

 

 

77

14.1

19.5

 

23.6

25.4

15.0

20.8

 

24.2

26.2

 

 

 

 

 

 

 

74

11.1

16.5

 

20.7

22.5

11.7

17.5

 

20.9

22.9

 

 

 

 

 

 

 

71

#N/A

13.6

 

17.8

19.6

#N/A

14.2

 

17.6

19.6

 

 

 

 

 

 

 

68

#N/A

10.7

 

14.9

16.7

#N/A

10.9

 

14.3

16.2

 

 

 

NET

CAP. MBH

 

 

30.3

27.2

 

25.0

26.7

31.5

28.2

 

26.0

27.7

 

 

POWER INPUT kW

 

3.14

3.12

 

3.04

3.06

3.24

3.22

 

3.14

3.16

 

CapacitySensible

 

 

 

 

 

86

21.7

26.6

 

25.0

26.7

23.9

27.9

 

26.0

27.7

 

MBH

 

DryEntering

°FBulb

 

83

18.8

24.1

 

25.0

26.7

20.6

26.3

 

26.0

27.7

 

 

 

 

 

 

 

 

 

105 °F

 

1

 

 

 

 

80

15.9

21.1

 

25.4

26.3

17.2

22.9

 

26.2

27.5

 

 

 

 

 

 

 

77

13.0

18.2

 

22.4

23.3

13.9

19.6

 

22.9

24.2

 

 

 

 

 

 

 

74

10.1

15.3

 

19.5

20.4

10.6

16.3

 

19.6

20.9

 

 

 

 

 

 

 

71

#N/A

12.4

 

16.6

17.5

#N/A

13.0

 

16.2

17.6

 

 

 

 

 

 

 

68

#N/A

9.5

 

13.7

14.6

#N/A

9.7

 

12.9

14.2

 

 

 

NET

CAP. MBH

 

 

28.0

24.9

 

23.2

24.4

29.3

26.1

 

24.4

25.6

 

 

POWER INPUT kW

 

3.45

3.43

 

3.37

3.42

3.56

3.54

 

3.48

3.53

 

CapacitySensible

 

 

 

 

 

86

20.7

24.9

 

23.2

24.4

22.8

26.1

 

24.4

25.6

 

MBH

 

DryEntering

°FBulb

 

83

17.7

22.8

 

23.2

24.4

19.5

25.0

 

24.4

25.6

 

 

 

 

 

 

 

 

 

115 °F

 

1

 

 

 

 

80

14.8

19.9

 

24.2

24.2

16.2

21.7

 

24.8

25.5

 

 

 

 

 

 

 

77

11.9

17.0

 

21.3

21.3

12.8

18.4

 

21.5

22.2

 

 

 

 

 

 

 

74

9.0

14.1

 

18.3

18.4

9.5

15.1

 

18.2

18.9

 

 

 

 

 

 

 

71

#N/A

11.2

 

15.4

15.4

#N/A

11.8

 

14.9

15.5

 

 

 

 

 

 

 

68

#N/A

8.3

 

12.5

12.5

#N/A

8.4

 

11.6

12.2

 

 

 

NET

CAP. MBH

 

 

25.6

22.7

 

21.4

22.2

27.2

24.0

 

22.7

23.5

 

 

POWER INPUT kW

 

3.76

3.74

 

3.70

3.78

3.87

3.85

 

3.82

3.89

 

CapacitySensible

 

 

 

 

 

86

19.6

23.3

 

21.4

22.2

21.7

24.3

 

22.7

23.5

 

MBH

 

DryEntering

°FBulb

 

83

16.7

21.6

 

21.4

22.2

18.4

23.8

 

22.7

23.5

 

 

 

 

 

 

 

 

 

125 °F

 

1

 

 

 

 

80

13.7

18.7

 

23.0

22.1

15.1

20.5

 

23.5

23.5

 

 

 

 

 

 

 

77

10.8

15.8

 

20.1

19.2

11.7

17.2

 

20.2

20.2

 

 

 

 

 

 

 

74

7.9

12.9

 

17.1

16.3

8.4

13.9

 

16.8

16.8

 

 

 

 

 

 

 

71

#N/A

10.0

 

14.2

13.4

#N/A

10.5

 

13.5

13.5

 

 

 

 

 

 

 

68

#N/A

7.1

 

11.3

10.4

#N/A

7.2

 

10.2

10.2

1.These capacities are net capacities - indoor fan heat deducted.

ALL SENSIBLE CAPACITY

Unitary Products Group

7

Image 7
Contents Utility Connections Made Easy Lower Installation CostOperating Efficiency On Site FlexibilityFull Perimeter Base Rails Condensate PANCondensate Drain Durable FinishReplacement Parts LOW MaintenanceSecured Service Access Ports Easy Service AccessManual Outdoor Damper Table of ContentsRectangle to Round Adapters Roof CurbsNominal Capacity KW MBH Seer EER COP Single Phase Three PhasePhysical Data HSPF1 RATING2Cooling Capacities 2 TON BHP024 Temperature of AIR on Indoor Coil Temperature AIR onOutdoor Coil Cooling Capacities 2-1/2 TON BHP030 Outdoor Coil WB F Cooling Capacities 3 TON BHP036Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Cooling Capacities 5 TON BHP060 Heating Capacities 2 TON BHP024 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR FHeating Capacities 2-1/2 TON BHP030 Heating Capacities 3-1/2 TON BHP042 Heating Capacities 3 TON BHP036Heating Capacities 5 TON BHP060 Heating Capacities 4 TON BHP048RESISTANCE, IWG Setting Airflow WattsAdditional Static Resistance Model no Motor Speed Unit External Static Pressure IWGField Wiring Diagram RLA LRA FLA Electric Data Basic UnitMCA BHPHACR2 Electrical Data 13 Seer Heat Pump / Electric HeatRLA LRA B1HP Operating Corner Weights Unit SizeApplication Data Model BHPUnit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460/575-3-60 Power Supply Unit Cabinet Indoor Supply FAN AssemblyOutdoor FAN Assembly General DescriptionElectric Heating Section Unit Operating CharacteristicsElectrical Requirements 036-21528-007-A-1205
Related manuals
Manual 28 pages 47.21 Kb

BHP024 specifications

The York BHP024 is a robust and efficient air conditioning unit designed to meet the needs of residential and commercial spaces. As part of the York BHP series, this model is tailored for environments requiring reliable cooling solutions, ensuring occupant comfort across varied climate conditions.

One of the standout features of the York BHP024 is its high-efficiency rating. The unit employs advanced cooling technology that allows it to deliver exceptional performance while consuming less energy, making it an environmentally-friendly choice. With a seasonal energy efficiency ratio (SEER) that exceeds industry standards, the BHP024 not only helps in reducing electricity bills but also contributes to lower greenhouse gas emissions.

The unit is equipped with a variable speed compressor that intelligently adjusts its operation based on the cooling demand. This not only enhances comfort by maintaining consistent temperatures but also minimizes energy wastage. The compressor, paired with a high-efficiency evaporator coil, optimizes heat exchange processes, further improving overall performance.

In terms of build quality, the York BHP024 features a durable cabinet constructed from corrosion-resistant materials, ensuring longevity even in challenging weather conditions. The unit’s design includes sound-dampening technologies, resulting in quieter operation, which is particularly important for residential applications.

Another notable characteristic of this model is its user-friendly control interface. The BHP024 comes with a programmable thermostat, enabling users to customize their cooling preferences and schedule operations according to their lifestyles. This smart control capability aligns with modern energy management practices, making it easier for users to optimize comfort and efficiency.

Installation versatility is also a key benefit of the York BHP024. The unit can be configured in various setups, accommodating different indoor layouts and requirements. This flexibility ensures that customers can find a suitable installation method that works for their space.

In conclusion, the York BHP024 is a cutting-edge air conditioning solution characterized by efficiency, durability, and user-friendly technology. Its advanced features make it a top choice for those seeking reliable and effective cooling solutions, whether for residential or light commercial applications. With its combination of high performance and robust construction, the BHP024 stands out as an ideal option for anyone looking to enhance their indoor climate control.