York BHP024 manual Cooling Capacities 3 TON BHP036, Outdoor Coil WB F

Page 8

036-21528-007-A-1205

TABLE 5: COOLING CAPACITIES - 3 TON (BHP036)

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE OF AIR ON INDOOR COIL

 

 

 

TEMPERATURE AIR ON

 

 

1050 CFM

 

 

1200 CFM

 

 

OUTDOOR COIL

 

 

 

 

 

WB °F

 

 

 

WB °F

 

 

 

 

 

 

 

 

 

72

67

 

62

57

72

67

 

62

57

 

 

 

NET CAP. MBH

 

41.1

37.5

 

34.5

34.3

42.4

38.6

 

35.5

35.3

 

 

POWER INPUT kW

 

2.89

2.81

 

2.73

2.73

3.00

2.91

 

2.83

2.82

 

CapacitySensible

 

 

 

 

 

86

25.6

32.3

 

34.5

34.3

28.2

35.5

 

35.5

35.3

 

MBH

 

DryEntering

°FBulb

 

83

22.5

29.3

 

33.5

33.6

24.7

32.0

 

35.5

35.3

 

 

 

 

 

 

 

 

 

85 °F

 

1

 

 

 

 

80

19.5

26.3

 

31.7

32.2

21.2

28.5

 

34.5

35.0

 

 

 

 

 

 

 

77

16.5

23.2

 

28.7

29.1

17.7

25.0

 

31.0

31.5

 

 

 

 

 

 

 

74

13.4

20.2

 

25.7

26.1

14.2

21.6

 

27.5

28.0

 

 

 

 

 

 

 

71

#N/A

17.2

 

22.6

23.1

#N/A

18.1

 

24.0

24.5

 

 

 

 

 

 

 

68

#N/A

14.1

 

19.6

20.0

#N/A

14.6

 

20.5

21.0

 

 

 

NET

CAP. MBH

 

 

38.5

34.9

 

32.5

32.6

39.4

35.8

 

33.3

33.4

 

 

POWER INPUT kW

 

3.21

3.15

 

3.05

3.06

3.31

3.25

 

3.15

3.16

 

CapacitySensible

 

 

 

 

 

86

25.0

30.9

 

32.5

32.6

27.5

33.9

 

33.3

33.4

 

MBH

 

DryEntering

°FBulb

 

83

22.0

27.9

 

31.9

32.0

24.0

30.4

 

33.3

33.4

 

 

 

 

 

 

 

 

 

95 °F

 

1

 

 

 

 

80

19.0

24.8

 

30.5

30.6

20.5

26.9

 

33.0

33.1

 

 

 

 

 

 

 

77

15.9

21.8

 

27.5

27.5

17.0

23.4

 

29.5

29.6

 

 

 

 

 

 

 

74

12.9

18.8

 

24.4

24.5

13.5

19.9

 

26.0

26.1

 

 

 

 

 

 

 

71

#N/A

15.7

 

21.4

21.5

#N/A

16.4

 

22.5

22.6

 

 

 

 

 

 

 

68

#N/A

12.7

 

18.4

18.5

#N/A

12.9

 

19.0

19.1

 

 

 

NET

CAP. MBH

 

 

35.6

32.1

 

29.5

30.4

36.4

32.8

 

30.2

31.1

 

 

POWER INPUT kW

 

3.61

3.52

 

3.44

3.45

3.70

3.61

 

3.53

3.54

 

CapacitySensible

 

 

 

 

 

86

23.9

29.4

 

29.5

30.4

26.2

31.9

 

30.2

31.1

 

MBH

 

DryEntering

°FBulb

 

83

20.9

26.6

 

29.2

30.0

22.7

28.9

 

30.2

31.1

 

 

 

 

 

 

 

 

 

105 °F

 

1

 

 

 

 

80

17.9

23.6

 

27.8

28.6

19.2

25.4

 

30.0

30.8

 

 

 

 

 

 

 

77

14.8

20.5

 

24.8

25.5

15.7

21.9

 

26.5

27.3

 

 

 

 

 

 

 

74

11.8

17.5

 

21.8

22.5

12.2

18.4

 

23.0

23.8

 

 

 

 

 

 

 

71

#N/A

14.5

 

18.7

19.5

#N/A

14.9

 

19.5

20.3

 

 

 

 

 

 

 

68

#N/A

11.4

 

15.7

16.4

#N/A

11.4

 

16.0

16.8

 

 

 

NET

CAP. MBH

 

 

32.6

29.3

 

26.5

28.2

33.3

29.9

 

27.0

28.8

 

 

POWER INPUT kW

 

4.01

3.88

 

3.83

3.84

4.10

3.97

 

3.91

3.92

 

CapacitySensible

 

 

 

 

 

86

22.8

27.8

 

26.5

28.2

25.0

29.9

 

27.0

28.8

 

MBH

 

DryEntering

°FBulb

 

83

19.8

25.3

 

26.5

28.0

21.5

27.4

 

27.0

28.8

 

 

 

 

 

 

 

 

 

115 °F

 

1

 

 

 

 

80

16.8

22.3

 

25.2

26.5

18.0

23.9

 

27.0

28.5

 

 

 

 

 

 

 

77

13.7

19.2

 

22.2

23.5

14.5

20.4

 

23.5

25.0

 

 

 

 

 

 

 

74

10.7

16.2

 

19.1

20.5

11.0

16.9

 

20.0

21.5

 

 

 

 

 

 

 

71

#N/A

13.2

 

16.1

17.4

#N/A

13.4

 

16.5

18.0

 

 

 

 

 

 

 

68

#N/A

10.1

 

13.1

14.4

#N/A

9.9

 

13.0

14.5

 

 

 

NET

CAP. MBH

 

 

29.7

26.4

 

23.5

26.0

30.2

26.9

 

23.9

26.4

 

 

POWER INPUT kW

 

4.41

4.25

 

4.21

4.22

4.49

4.33

 

4.29

4.30

 

CapacitySensible

 

 

 

 

 

86

21.7

26.3

 

23.5

26.0

23.7

27.9

 

23.9

26.4

 

MBH

 

DryEntering

°FBulb

 

83

18.7

24.0

 

23.8

25.9

20.2

25.9

 

23.9

26.4

 

 

 

 

 

 

 

 

 

125 °F

 

1

 

 

 

 

80

15.7

21.0

 

22.6

24.5

16.7

22.4

 

24.1

26.2

 

 

 

 

 

 

 

77

12.6

17.9

 

19.5

21.5

13.2

18.9

 

20.6

22.7

 

 

 

 

 

 

 

74

9.6

14.9

 

16.5

18.4

9.7

15.4

 

17.1

19.2

 

 

 

 

 

 

 

71

#N/A

11.9

 

13.5

15.4

#N/A

11.9

 

13.6

15.7

 

 

 

 

 

 

 

#78

#N/A

8.8

 

10.4

12.4

#N/A

8.4

 

10.1

12.2

1.These capacities are net capacities - indoor fan heat deducted.

ALL SENSIBLE CAPACITY

8

Unitary Products Group

Image 8
Contents Lower Installation Cost Operating EfficiencyOn Site Flexibility Utility Connections Made EasyCondensate PAN Condensate DrainDurable Finish Full Perimeter Base RailsLOW Maintenance Secured Service Access PortsEasy Service Access Replacement PartsTable of Contents Rectangle to Round AdaptersRoof Curbs Manual Outdoor DamperMBH Seer EER COP Single Phase Three Phase Physical DataHSPF1 RATING2 Nominal Capacity KWOutdoor Coil Temperature of AIR on Indoor Coil Temperature AIR onCooling Capacities 2 TON BHP024 Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Outdoor Coil WB FCooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Cooling Capacities 5 TON BHP060 Heating Capacities 2-1/2 TON BHP030 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR FHeating Capacities 2 TON BHP024 Heating Capacities 3 TON BHP036 Heating Capacities 3-1/2 TON BHP042Heating Capacities 4 TON BHP048 Heating Capacities 5 TON BHP060Setting Airflow Watts Additional Static ResistanceModel no Motor Speed Unit External Static Pressure IWG RESISTANCE, IWGField Wiring Diagram Electric Data Basic Unit MCABHP RLA LRA FLARLA LRA Electrical Data 13 Seer Heat Pump / Electric HeatHACR2 Operating Corner Weights Unit Size Application DataModel BHP B1HPUnit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460/575-3-60 Power Supply Indoor Supply FAN Assembly Outdoor FAN AssemblyGeneral Description Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section 036-21528-007-A-1205
Related manuals
Manual 28 pages 47.21 Kb

BHP024 specifications

The York BHP024 is a robust and efficient air conditioning unit designed to meet the needs of residential and commercial spaces. As part of the York BHP series, this model is tailored for environments requiring reliable cooling solutions, ensuring occupant comfort across varied climate conditions.

One of the standout features of the York BHP024 is its high-efficiency rating. The unit employs advanced cooling technology that allows it to deliver exceptional performance while consuming less energy, making it an environmentally-friendly choice. With a seasonal energy efficiency ratio (SEER) that exceeds industry standards, the BHP024 not only helps in reducing electricity bills but also contributes to lower greenhouse gas emissions.

The unit is equipped with a variable speed compressor that intelligently adjusts its operation based on the cooling demand. This not only enhances comfort by maintaining consistent temperatures but also minimizes energy wastage. The compressor, paired with a high-efficiency evaporator coil, optimizes heat exchange processes, further improving overall performance.

In terms of build quality, the York BHP024 features a durable cabinet constructed from corrosion-resistant materials, ensuring longevity even in challenging weather conditions. The unit’s design includes sound-dampening technologies, resulting in quieter operation, which is particularly important for residential applications.

Another notable characteristic of this model is its user-friendly control interface. The BHP024 comes with a programmable thermostat, enabling users to customize their cooling preferences and schedule operations according to their lifestyles. This smart control capability aligns with modern energy management practices, making it easier for users to optimize comfort and efficiency.

Installation versatility is also a key benefit of the York BHP024. The unit can be configured in various setups, accommodating different indoor layouts and requirements. This flexibility ensures that customers can find a suitable installation method that works for their space.

In conclusion, the York BHP024 is a cutting-edge air conditioning solution characterized by efficiency, durability, and user-friendly technology. Its advanced features make it a top choice for those seeking reliable and effective cooling solutions, whether for residential or light commercial applications. With its combination of high performance and robust construction, the BHP024 stands out as an ideal option for anyone looking to enhance their indoor climate control.