Acknowledgement
[j][][Set ID][][OK/NG][Data][x]
27. Elapsed time return (Command : d l)
To read the elapsed time.
Transmission
[d][l][][Set ID][][Data][Cr]
*The data is always FF(in Hex). Acknowledgement
[l][][Set ID][][OK/NG][Data][x]
*The data means used hours. (Hexadecimal code)
28.Temperature value (Command : d n)
To read the inside temperature value.
Transmission
[d][n][][Set ID][][Data][Cr]
*The data is always FF(in Hex). Acknowledgement
[n][][Set ID][][OK/NG][Data][x]
*The data is 1 byte long in Hexadecimal.
29.Lamp fault Check (Command : d p)
To check lamp fault.
Transmission
[d][p][][Set ID][][Data][Cr]
*The data is always FF(in Hex). Acknowledgement
ENWW | Transmission / Receiving Protocol 55 |