York DJ 150 manual Factory Installed Options

Page 5

036-21484-001-B-0103

and protect the unit during shipment. The rails offer fork- lift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof.

Easy Installation – Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connec- tions can be made quickly and with a minimum amount of field labor.

All units are shipped with 2” throw-away filters installed.

Wide Range of Indoor Airflows – All indoor fan motors are belt-drive type providing maximum flexibility to han- dle most airflow requirements. For high static applica- tions, factory installed alternate indoor fan motors are available. With the optional indoor fan motor, all units can supply nominal airflow at a minimum of 1.5” ESP.

Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10- year warranty.

FACTORY INSTALLED OPTIONS

YORK® offers several equipment options/accessories factory installed, for the Predatorline.

Alternate Indoor Blower Motor - For applications with high restrictions, units are offered with optional indoor motors that provide higher static output and/or higher air- flow, depending upon the installer’s needs.

Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering the space between the inner condenser coil and the main cabinet. This is not a hail guard kit.

Convenience Outlet - (Non-Powered) - This option locates a 120V GFCI single-phase outlet with cover on the corner of the unit housing the compressors. The installer must provide the 120V single-phase power source and wiring. Factory installed option only.

Dirty Filter Switch - This kit includes a differential pres- sure switch that energizes the fault light on the unit ther- mostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory.

Disconnect Switch - For gas heat units, a HACR breaker sized to the unit is provided. For cooling units with electric heat, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only.

Downflow Economizer - (With barometric relief) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type. The economizers are shipped installed and wired. The installer needs only

assemble and mount the outdoor air hood. The econo- mizer has spring return, fully modulating damper actua- tors and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrig- eration to economizer operation is regulated by the stan- dard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation.

With single enthalpy input, the economizer control moni- tors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible.

Sideflow Economizer - (Without barometric relief) - All features as the downflow economizer exist except you must order the barometric relief separately.

Motorized Outdoor Air Damper - The motorized out- door air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The out- door air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory.

Power Exhaust (Downflow only) - This accessory installs in the unit with a down flow economizer. Power exhaust plugs into the connector in the unit bulkhead.

Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment.

Stainless Steel Heat Exchanger - For applications in corrosive environments, this option provides a full stain- less steel heat exchanger assembly.

Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against cor- rosion due to harsh environments.

Technicoat Evaporator Coil - The evaporator coil is coated with a phenolic coating for protection against harsh environments.

Novar® BAS Control - The Novar® ETC-3 building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building auto- mation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

Unitary Products

5

Image 5
Contents Guidemagnumtm Table of Contents Features Unitary Products Factory Installed Options Field Installed Accessories Part Number Description Weight AccessoriesOptions Product NomenclatureAdditional Options Abbreviations Installation AbbreviationsAirflow Abbreviations Physical Data Unit Voltage Limitations DJ 150 12-1/2 TON Capacity Ratings3750 DJ 150 12-1/2 TON Cooling Capacity TableElectric Heat Multipliers DJ 150 12-1/2 TON Electrical DataBlower Performance 12-1/2 TON Side Duct Blower Performance 12-1/2 TON Downshot Additional Static Resistance Indoor Blower SpecificationsUnit Weight Unit 4 Point Load Point Load WeightDetail C Unit ClearancesPredator Magnum Roof Curb Dimensions Bottom Duct Openings from Above Downflow Economizer Hood Detail Cooling Unit with GAS Heat Wiring 230 V. Diagram Cooling Unit W/WO Electric Heat Wiring Diagram Cooling Unit with GAS Heat Wiring 460, 575 & 50 HZ Diagram Outdoor Condenser FAN Assembly Indoor Evaporator FAN AssemblyGeneral DescriptionGAS Heating Section if Equipped Unit Operating CharacteristicsElectric Heating Section if Required Electrical RequirementsOther PRE-ENGINEERED Accessories AVAIL- Able Additonal Factory Installed OptionsCopyright by Unitary Products 2003. All rights reserved