York DH 180, DH 210, DH 300, DH 240 warranty Input

Page 13

262260-YTG-E-1008

TABLE 5: DH 210 COOLING CAPACITIES (17.5 TON) (CONTINUED)

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

115°F

 

 

 

 

 

 

 

 

125°F

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL

 

TOTAL

POWER

 

SENSIBLE CAPACITY, MBH

 

TOTAL

POWER

 

SENSIBLE CAPACITY, MBH

 

 

 

ENTERING DRY BULB, °F

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

CFM

 

WB

MBH

KW

90

85

80

 

75

70

65

MBH

KW

90

85

80

75

70

65

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

217.8

12.5

112.3

87.3

62.4

 

-

-

-

207.3

10.1

108.4

83.5

58.5

-

-

-

 

 

72

199.9

12.2

143.0

118.0

93.1

 

68.1

-

-

189.9

9.9

138.0

113.1

88.1

63.2

-

-

5250

 

67

182.0

12.0

173.7

148.7

123.8

 

98.9

73.9

-

172.5

9.7

167.6

142.6

117.7

92.8

67.8

-

 

 

62

169.7

11.8

169.7

169.7

146.7

 

121.7

96.8

71.8

163.2

9.5

163.2

163.2

140.6

115.6

90.7

65.7

 

 

57

170.9

11.8

170.9

170.9

146.0

 

121.1

96.1

71.2

165.4

9.6

165.4

165.4

138.8

113.8

88.9

63.9

 

 

77

223.9

16.9

142.1

98.9

69.4

 

-

-

-

212.0

16.5

141.0

95.0

65.5

-

-

-

 

 

72

205.5

16.5

162.5

133.0

103.5

 

74.1

-

-

194.2

16.2

157.5

128.0

98.5

69.1

-

-

6125

 

67

187.1

16.1

182.9

167.2

137.7

 

108.2

78.7

-

176.5

15.8

174.0

161.1

131.6

102.1

72.6

-

 

 

62

174.4

15.8

174.4

174.4

163.1

 

133.6

104.2

74.7

167.0

15.6

167.0

167.0

157.2

127.7

98.2

68.7

 

 

57

175.7

15.8

175.7

175.7

162.4

 

132.9

103.4

74.0

169.2

15.7

169.2

169.2

155.2

125.7

96.2

66.7

 

 

77

229.9

21.2

172.0

110.4

76.4

 

-

-

-

216.8

23.0

173.6

106.4

72.4

-

-

-

 

 

72

211.0

20.7

182.0

148.0

114.0

 

80.0

-

-

198.6

22.5

177.0

143.0

109.0

74.9

-

-

7000

 

67

192.1

20.2

192.1

185.6

151.6

 

117.6

83.6

-

180.4

22.0

180.4

179.5

145.5

111.5

77.5

-

 

 

62

179.1

19.9

179.1

179.1

179.6

 

145.6

111.6

77.5

170.8

21.6

170.8

170.8

170.8

139.7

105.7

71.7

 

 

57

180.4

19.9

180.4

180.4

178.8

 

144.8

110.8

76.7

173.1

21.7

173.1

173.1

171.6

137.5

103.5

69.5

 

 

72

215.7

20.8

200.1

161.4

122.6

 

83.9

-

-

203.1

22.6

195.0

156.3

117.5

78.8

-

-

7875

 

67

196.4

20.3

196.4

193.2

163.1

 

124.4

85.6

-

184.5

22.1

184.5

184.1

156.9

118.2

79.4

-

 

62

183.1

20.0

183.1

183.1

183.4

 

144.6

105.9

67.1

174.7

21.7

174.7

174.7

174.7

137.4

98.7

59.9

 

 

 

 

 

57

184.4

20.0

184.4

184.4

183.6

 

144.9

106.1

67.4

177.0

21.8

177.0

177.0

176.3

137.5

98.8

60.0

 

 

72

220.4

20.9

218.2

174.8

131.3

 

87.8

-

-

207.7

22.7

207.7

169.5

126.1

82.6

-

-

8750

 

67

200.7

20.4

200.7

200.7

174.6

 

131.1

87.7

-

188.7

22.2

188.7

188.7

168.4

124.9

81.4

-

 

62

187.1

20.1

187.1

187.1

187.1

 

143.6

100.2

56.7

178.6

21.8

178.6

178.6

178.6

135.1

91.6

48.1

 

 

 

 

 

57

188.5

20.1

188.5

188.5

188.5

 

145.0

101.5

58.1

181.0

21.9

181.0

181.0

181.0

137.5

94.0

50.5

1.These capacities are gross ratings. For net capacity, deduct the air blower motor, MBH = 3.415 x KW. Refer to the appropriate Blower Performance Table for the KW of the supply air blower motor.

2.These ratings include the condenser fan motors (Total 1 KW) and the compressor motors but not the supply air blower motor.

Nominal Rating

Johnson Controls Unitary Products

13

Image 13
Contents Description Single Package GAS/ELECTRIC Units AIR ConditionersTable of Contents Ton Sunline Ultra Model Number Nomenclature Product NomenclatureFactory installed power exhaust are suitable for bottom FeaturesUnit Cutaway FACTORY-INSTALLED OptionsJohnson Controls Unitary Products YTG-E-1008 FIELD-INSTALLED Accessories Capacity Ratings ARI Indoor Sound Power RATING1GAS Heat RATINGS1 CAP.1 INPUT2 CFM MBH DH 180 Cooling Capacities 15 TONTotal Power Sensible CAPACITY, MBH DH 210 Cooling Capacities 17.5 TON Input DH 240 Cooling Capacities 20 TON 217.3 24.8 139.8 DH 300 Cooling Capacities 25 TON 302.0 29.3 147.5 AIR Temp Altitude Feet Altitude Correction FactorsALTITUDE/TEMPERATURE Conversion Factor Motor CFM Pulley Speed Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Blower Motor and Drive Data Power Exhaust PerformanceStatic RESISTANCES1 Model OD FAN Conv Fuse Blower Circuit Compressors Heater Option MINMotors Outlet BRKR1 Model Stages Amps Nage230 None 80.9 100 None 130.5 150 E18 13.5 37.5 DH Voltage LIMITATIONS1 Power Supply VoltageElectric Heat Correction Factors Nominal VoltageSupply FAN VFD WEIGHTS, in LBS Operating Weights LBSPhysical Data Front View Rear View Dimensions Clearance Minimum ClearancesUnit Center of Gravity Operating Unit Model Weight DH 180, 210, 240 & 300 6 Point Load Weight DistributionUnit Roof Curb Dimensions Typical Rooftop Installation General Guide SpecificationsDescription Outdoor Condenser FAN Assembly Electrical Requirements Other Factory Installed Options

DH 240, DH 300, DH 180, DH 210 specifications

York International is known for its innovative and efficient HVAC systems, particularly their range of air conditioning units including the York DH series, comprising models DH 240, DH 300, DH 180, and DH 210. These units reflect state-of-the-art technology designed for optimal performance, energy efficiency, and reliability in diverse applications.

The York DH 240 is a versatile unit engineered for medium to large spaces. It features a compact design while delivering robust cooling performance. The incorporation of advanced inverter technology allows for precise temperature control and enhanced energy savings. Additionally, this model boasts an intelligent control system that ensures optimal operation based on real-time load conditions, further conserving energy.

The DH 300 model is designed for larger installations and offers unmatched cooling capacity. Its high-efficiency scroll compressors and variable speed fans minimize energy consumption, making it a wise choice for environmentally conscious businesses. Moreover, this unit includes a sophisticated microprocessor control system that facilitates monitoring and maintenance, ensuring peak operational efficiency throughout its lifespan.

The York DH 180 is tailored for smaller commercial applications where space is a premium. Its lightweight, low-profile design allows for easy installation while not compromising on performance. The DH 180 incorporates advanced filtration technology, ensuring high indoor air quality. With user-friendly digital controls, this unit can be customized to meet specific climate requirements.

Finally, the DH 210 offers a balanced solution for mid-range cooling needs with features that promote sustainability and efficiency. The unit is equipped with ecologically friendly refrigerants that comply with the latest environmental regulations. The incorporation of multi-stage filtration in the DH 210 ensures clean air delivery while reducing operational costs due to improved airflow design.

Collectively, the York DH series distinguishes itself through a commitment to quality, efficiency, and innovation. Each model, whether DH 240, DH 300, DH 180, or DH 210, is designed with advanced technology that prioritizes user experience and environmental sustainability. York's dedication to robust engineering ensures that these models not only meet but exceed the demands of modern commercial air conditioning needs, providing reliable solutions for diverse operational challenges.