York DH 240, DH 210 Blower Motor and Drive Data, Static RESISTANCES1, Power Exhaust Performance

Page 27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

262260-YTG-E-1008

TABLE 16: BLOWER MOTOR AND DRIVE DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR1

ADJUSTABLE MOTOR PULLEY

FIXED BLOWER PULLEY

 

BELT

 

MODEL

 

BLOWER

 

(NOTCHED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRIVE

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFF.

DESIG-

OUTSIDE

PITCH

BORE

DESIG-

OUTSIDE

PITCH

BORE

DESIG-

PITCH

 

SIZE

 

(RPM)

 

 

 

 

 

HP

FRAME

(%)

NATION

DIA.

DIA.

(IN.)

NATION

DIA.

DIA.

(IN.)

NATION

LENGTH

QTY.

 

 

 

 

 

 

 

 

 

 

(IN.)

(IN.)

 

 

(IN.)

(IN.)

 

 

(IN.)

 

 

Standard

850/1065

 

 

 

 

 

4.3-5.32

 

BK90

8.75

8.4

1

BX70

82.8

1

15 TON

 

 

5

184 T

83

1VP56

5.35

1-1/8

 

 

 

 

 

 

 

High

965/1190

BK80

7.75

7.4

1

BX68

69.8

1

 

Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17.5 &

Standard

870/1025

 

 

 

 

 

5.5-6.52

 

BK120

11.75

11.4

1-3/16

BX83

84.8

1

High

 

7.5

213 T

89

1VP68

6.75

1-3/8

 

 

 

 

 

 

 

20 TON

950/1120

BK110

10.75

10.4

1-3/16

BX81

82.8

1

Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

950/1120

10

215 T

89.5

1VP68

6.75

5.5-6.52

1-3/8

1B5V110

11.3

11.1

1-7/16

BX81

82.8

1

25 TON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1140/1365

15

254 T

91

1VP75X

7.5

6.2-7.4

1-5/8

1B5V94

9.7

9.5

1-7/16

5VX840

84.0

1

 

Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.All motors have a nominal speed of 1800 RPM, a 1.15 service factor and a solid base. They can operate to the limit of their service factor because they are located in the moving air, upstream of any heating device.

2.Do NOT close this pulley below 1 turn open.

TABLE 17: STATIC RESISTANCES1

 

 

 

 

 

 

 

 

RESISTANCE, IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 TON

 

 

17.5 TON

 

 

20 TON

 

 

25 TON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4500

6000

7200

6000

 

8000

 

9000

 

6000

7000

9400

7500

10000

12500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WET COIL

 

0.1

0.1

0.1

0.1

 

0.1

 

0.1

 

0.1

0.1

0.1

0.1

0.1

0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18kW

0.3

0.4

0.4

0.4

 

0.4

 

0.5

 

0.4

0.4

0.5

0.4

0.6

0.6

ELECTRIC HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36kW

0.3

0.4

0.5

0.4

 

0.5

 

0.5

 

0.4

0.5

0.5

0.5

0.5

0.6

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54kW

0.4

0.5

0.5

0.5

 

0.5

 

0.6

 

0.5

0.5

0.6

0.5

0.6

0.7

(DH models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72kW

0.4

0.5

0.5

0.5

 

0.5

 

0.6

 

0.5

0.5

0.6

0.5

0.6

0.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECONOMIZER OPTION

 

0.1

0.1

0.1

0.1

 

0.1

 

0.2

 

0.1

0.1

0.2

0.1

0.2

0.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL DUCT CONNECTIONS2

0.1

0.2

0.3

0.2

 

0.3

 

0.5

 

0.2

0.3

0.5

0.3

0.5

0.6

1.Deduct theses resistance values from the available unit ESP values listed in the respective blower performance table except for Horizontal Duct Connections.

2.Since the resistance to air flow will be less for horizontal duct connections than for bottom duct connections, add these pressures to the ESP values on the respective unit’s blower performance table.

TABLE 18: POWER EXHAUST PERFORMANCE

MOTOR

 

 

 

STATIC RESISTANCE OF RETRUN DUCTWORK, IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED1

 

0.2

0.3

 

 

0.4

 

0.5

 

0.6

CFM

 

kW

CFM

kW

CFM

 

kW

CFM

 

kW

CFM

 

kW

 

 

 

 

 

HIGH2

5250

 

0.83

4500

0.85

4200

 

0.88

3750

 

0.93

3000

 

0.99

MEDIUM

4900

 

0.77

3900

0.79

3500

 

0.82

2900

 

0.85

-

 

-

LOW

4400

 

0.72

3700

0.74

3000

 

0.78

-

 

-

-

 

-

1.Power exhaust motor is a 3/4 HP, PSC type with sleeve bearings, a 48 frame and inherent protection.

2.The factory setting.

Johnson Controls Unitary Products

27

Image 27
Contents Description Single Package GAS/ELECTRIC Units AIR ConditionersTable of Contents Ton Sunline Ultra Model Number Nomenclature Product NomenclatureFactory installed power exhaust are suitable for bottom FeaturesUnit Cutaway FACTORY-INSTALLED OptionsJohnson Controls Unitary Products YTG-E-1008 FIELD-INSTALLED Accessories Indoor Sound Power RATING1 Capacity Ratings ARIGAS Heat RATINGS1 CAP.1 INPUT2 CFM MBH DH 180 Cooling Capacities 15 TONTotal Power Sensible CAPACITY, MBH DH 210 Cooling Capacities 17.5 TON Input DH 240 Cooling Capacities 20 TON 217.3 24.8 139.8 DH 300 Cooling Capacities 25 TON 302.0 29.3 147.5 AIR Temp Altitude Feet Altitude Correction FactorsALTITUDE/TEMPERATURE Conversion Factor Motor CFM Pulley Speed Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Power Exhaust Performance Blower Motor and Drive DataStatic RESISTANCES1 Nage Compressors Heater Option MINModel OD FAN Conv Fuse Blower Circuit Motors Outlet BRKR1 Model Stages Amps230 None 80.9 100 None 130.5 150 E18 13.5 37.5 Nominal Voltage Power Supply VoltageDH Voltage LIMITATIONS1 Electric Heat Correction FactorsOperating Weights LBS Supply FAN VFD WEIGHTS, in LBSPhysical Data Front View Rear View Dimensions Clearance Minimum ClearancesUnit Center of Gravity Operating Unit Model Weight DH 180, 210, 240 & 300 6 Point Load Weight DistributionUnit Roof Curb Dimensions Typical Rooftop Installation Guide Specifications GeneralDescription Outdoor Condenser FAN Assembly Electrical Requirements Other Factory Installed Options

DH 240, DH 300, DH 180, DH 210 specifications

York International is known for its innovative and efficient HVAC systems, particularly their range of air conditioning units including the York DH series, comprising models DH 240, DH 300, DH 180, and DH 210. These units reflect state-of-the-art technology designed for optimal performance, energy efficiency, and reliability in diverse applications.

The York DH 240 is a versatile unit engineered for medium to large spaces. It features a compact design while delivering robust cooling performance. The incorporation of advanced inverter technology allows for precise temperature control and enhanced energy savings. Additionally, this model boasts an intelligent control system that ensures optimal operation based on real-time load conditions, further conserving energy.

The DH 300 model is designed for larger installations and offers unmatched cooling capacity. Its high-efficiency scroll compressors and variable speed fans minimize energy consumption, making it a wise choice for environmentally conscious businesses. Moreover, this unit includes a sophisticated microprocessor control system that facilitates monitoring and maintenance, ensuring peak operational efficiency throughout its lifespan.

The York DH 180 is tailored for smaller commercial applications where space is a premium. Its lightweight, low-profile design allows for easy installation while not compromising on performance. The DH 180 incorporates advanced filtration technology, ensuring high indoor air quality. With user-friendly digital controls, this unit can be customized to meet specific climate requirements.

Finally, the DH 210 offers a balanced solution for mid-range cooling needs with features that promote sustainability and efficiency. The unit is equipped with ecologically friendly refrigerants that comply with the latest environmental regulations. The incorporation of multi-stage filtration in the DH 210 ensures clean air delivery while reducing operational costs due to improved airflow design.

Collectively, the York DH series distinguishes itself through a commitment to quality, efficiency, and innovation. Each model, whether DH 240, DH 300, DH 180, or DH 210, is designed with advanced technology that prioritizes user experience and environmental sustainability. York's dedication to robust engineering ensures that these models not only meet but exceed the demands of modern commercial air conditioning needs, providing reliable solutions for diverse operational challenges.