York DH 300, DH 210, DH 180, DH 240 warranty Front View

Page 34

262260-YTG-E-1008

BLOWER ACCESS

 

(Location Of

FIELD-SUPPLIED

BLOWER MOTOR ACCESS Optional VFD)

DISCONNECT SWITCH

(Location Of Optional

LOCATION

VFD Bypass)

 

BLOWER

 

COMPARTMENT

 

ACCESS

 

(Auxiliary)

 

DOT PLUG

 

(For pressure

 

Drop Reading)

 

ELECTRIC

 

GAS HEAT

 

ACCESS

 

ECONOMIZER / MOTORIZED DAMPER, FIXED OUTDOOR INTAKE AIR AND POWER EXHAUST RAIN HOODS

(See detail "Y")

COMPRESSOR ACCESS (See detail "X")

OPTIONAL COIL

GUARD KIT

48-5/8" (15 Ton)

52-5/8" (17.5 thru 25 Ton)

VENT AIR

OUTLET

HOODS

COMBUSTION

AIR INLET

HOOD

(C)

GAS SUPPLY ENTRY

 

 

 

 

Ton)

 

 

 

 

(15 .

 

 

 

 

 

(17

5

Ton)

 

-1/4"

 

 

 

 

 

 

 

25

 

125

-1/4"

 

 

 

 

thru

 

 

136

 

 

 

 

6-3/8"

21"

5"

7-1/8"

9-3/4"

5-7/8"

46-5/8"

CONDENSER

COILS

92"

(A)

CONTROL WIRING ENTRY

CONTROL BOX

ACCESS 35"

11-1/2"

BOTTOM SUPPLY

AND RETURN

(B)

POWER WIRING ENTRY

FRONT

VIEW

 

 

(15

Ton)

 

 

 

.5

on)

-1/4"

(17

 

T

24

-1/4"

25

 

 

 

35

thru

 

 

33"

 

 

 

 

 

AIR OPENINGS

(See Note)

RETURN

AIR

SUPPLY

AIR

3-3/4"

RETURN AIR

SUPPLY AIR

OUTDOOR AIR

UNIT BASE WITH RAILS

 

 

Shown separately to illustrate

(D)

Bottom Duct openings, Power

GAS SUPPLY

and Gas Piping Connection

ENTRY

locations

 

NOTE:

For curb mounted units, refer to the curb hanger dimensions of the curb for the proper size of the supply and return air duct connections.

2-3/4" 21-1/2"

11-1/8"

(B)

POWER WIRING ENTRY

(A)

8-1/8"CONTROL WIRING

ENTRY

46-5/8"

9-1/4"

12-1/2" 9-3/4"

OUTDOOR AIR (Economizer)

All dimensions are in inches. They are subject to change without notice. Certi- fied dimensions will be provided upon request.

FIGURE 4 - UNIT DIMENSIONS DH180, 210, 240 & 300 (FRONT VIEW)

TABLE 30: UTILITIES ENTRY DATA

HOLE

OPENING SIZE

USED FOR

 

(DIA.)

 

 

 

 

 

A

1-1/8” KO

Control Wiring

 

Side

3/4” NPS (Fem.)

 

Bottom

 

 

 

 

 

 

 

 

B

3-5/8” KO

Power Wiring

 

Side

 

 

 

3” NPS (Fem.)

 

Bottom

 

 

 

 

 

 

 

C

2-3/8” KO

Gas Piping

(Front)1

D

1-11/16” Hole

Gas Piping (Bottom)1, 2

1.One-inch gas piping NPT required.

2.Opening in the bottom of the unit can be located by the slice in the insulation.

NOTE: All entry holes should be field sealed to prevent rain water entry into the building.

34

Johnson Controls Unitary Products

Image 34
Contents Single Package GAS/ELECTRIC Units AIR Conditioners DescriptionTable of Contents Product Nomenclature Ton Sunline Ultra Model Number NomenclatureFeatures Factory installed power exhaust are suitable for bottomFACTORY-INSTALLED Options Unit CutawayJohnson Controls Unitary Products YTG-E-1008 FIELD-INSTALLED Accessories Capacity Ratings ARI Indoor Sound Power RATING1GAS Heat RATINGS1 DH 180 Cooling Capacities 15 TON CAP.1 INPUT2 CFM MBHTotal Power Sensible CAPACITY, MBH DH 210 Cooling Capacities 17.5 TON Input DH 240 Cooling Capacities 20 TON 217.3 24.8 139.8 DH 300 Cooling Capacities 25 TON 302.0 29.3 147.5 Altitude Correction Factors AIR Temp Altitude FeetALTITUDE/TEMPERATURE Conversion Factor Motor CFM Pulley Speed Volt Standard Drive 6000 7000 8000 9000 9400 965 980 1025 1065 1125 1170 870 900 930 950 980 995 1015 6000 7000 8000 9000 9400 7500 8750 10000 11250 12500 Blower Motor and Drive Data Power Exhaust PerformanceStatic RESISTANCES1 Motors Outlet BRKR1 Model Stages Amps Compressors Heater Option MINModel OD FAN Conv Fuse Blower Circuit Nage230 None 80.9 100 None 130.5 150 E18 13.5 37.5 Electric Heat Correction Factors Power Supply VoltageDH Voltage LIMITATIONS1 Nominal VoltageSupply FAN VFD WEIGHTS, in LBS Operating Weights LBSPhysical Data Front View Rear View Dimensions Minimum Clearances ClearanceUnit Center of Gravity DH 180, 210, 240 & 300 6 Point Load Weight Distribution Operating Unit Model WeightUnit Roof Curb Dimensions Typical Rooftop Installation General Guide SpecificationsDescription Outdoor Condenser FAN Assembly Electrical Requirements Other Factory Installed Options

DH 240, DH 300, DH 180, DH 210 specifications

York International is known for its innovative and efficient HVAC systems, particularly their range of air conditioning units including the York DH series, comprising models DH 240, DH 300, DH 180, and DH 210. These units reflect state-of-the-art technology designed for optimal performance, energy efficiency, and reliability in diverse applications.

The York DH 240 is a versatile unit engineered for medium to large spaces. It features a compact design while delivering robust cooling performance. The incorporation of advanced inverter technology allows for precise temperature control and enhanced energy savings. Additionally, this model boasts an intelligent control system that ensures optimal operation based on real-time load conditions, further conserving energy.

The DH 300 model is designed for larger installations and offers unmatched cooling capacity. Its high-efficiency scroll compressors and variable speed fans minimize energy consumption, making it a wise choice for environmentally conscious businesses. Moreover, this unit includes a sophisticated microprocessor control system that facilitates monitoring and maintenance, ensuring peak operational efficiency throughout its lifespan.

The York DH 180 is tailored for smaller commercial applications where space is a premium. Its lightweight, low-profile design allows for easy installation while not compromising on performance. The DH 180 incorporates advanced filtration technology, ensuring high indoor air quality. With user-friendly digital controls, this unit can be customized to meet specific climate requirements.

Finally, the DH 210 offers a balanced solution for mid-range cooling needs with features that promote sustainability and efficiency. The unit is equipped with ecologically friendly refrigerants that comply with the latest environmental regulations. The incorporation of multi-stage filtration in the DH 210 ensures clean air delivery while reducing operational costs due to improved airflow design.

Collectively, the York DH series distinguishes itself through a commitment to quality, efficiency, and innovation. Each model, whether DH 240, DH 300, DH 180, or DH 210, is designed with advanced technology that prioritizes user experience and environmental sustainability. York's dedication to robust engineering ensures that these models not only meet but exceed the demands of modern commercial air conditioning needs, providing reliable solutions for diverse operational challenges.