York D2EG 060 894 885 940 980 1014 1020 1047 1095, 855 815 903 860 950 905 988 940 1022 970, 1665

Page 10

035-14832-003-A-0204

TABLE 7 - SUPPLY AIR PERFORMANCE - 5 Ton w/Belt-Drive Blower 5 TON - SIDE DUCT CONNECTIONS @230/460/575 Volts

MODEL

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.20

0.30

0.40

0.50

0.60

0.70

0.80

DEG

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2500

1059

1560

1077

1590

1095

1630

1114

1650

1134

1660

1158

1685

1181

1720

 

2400

1032

1405

1054

1470

1074

1525

1094

1560

1116

1595

1140

1620

1167

1640

 

2300

1005

1260

1024

1275

1049

1370

1069

1440

1090

1475

1116

1505

1142

1535

 

2200

980

1160

1002

1170

1022

1190

1044

1250

1066

1350

1090

1410

1117

1440

 

2100

930

1060

957

1070

983

1080

1010

1100

1039

1160

1064

1260

1092

1340

060

2000

877

950

908

975

941

1000

976

1020

1009

1050

1040

1100

1070

1225

 

1900

-

-

-

-

894

885

940

940

980

980

1014

1020

1047

1095

 

1800

-

-

-

-

855

815

903

860

950

905

988

940

1022

970

 

1700

-

-

-

-

-

-

884

815

925

850

964

880

1001

910

 

1600

-

-

-

-

-

-

864

770

908

805

948

835

987

870

 

1500

-

-

-

-

-

-

-

-

882

740

926

780

965

830

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.90

1.00

1.10

1.20

1.30

1.40

1.50

DEG

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2500

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

2400

1193

1665

-

-

-

-

-

-

-

-

-

-

-

-

 

2300

1170

1580

1202

1620

-

-

-

-

-

-

-

-

-

-

 

2200

1148

1480

1180

1530

-

-

-

-

-

-

-

-

-

-

 

2100

1121

1385

1155

1425

1190

1475

-

-

-

-

-

-

-

-

060

2000

1100

1285

1133

1340

1169

1385

1205

1445

-

-

-

-

-

-

 

1900

1079

1180

1110

1240

1143

1280

1178

1330

1222

1375

-

-

-

-

 

1800

1058

1060

1090

1135

1122

1190

1158

1240

1196

1295

-

-

-

-

 

1700

1035

960

1071

1030

1103

1100

1134

1140

1164

1175

1197

1205

-

-

 

1600

1020

900

1056

965

1088

1035

1118

1065

1145

1105

1170

1130

1198

1150

 

1500

1004

860

1038

880

1070

925

1101

980

1130

1045

1158

1075

1184

1110

NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.

*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE GAS-FIRED HEAT EXCHANGERS. REFER TO TABLE 8 FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.

10

Unitary Products Group

Image 10
Contents Inspection For Your SafetyGeneral ReferenceTable of Contents Installation Filters Service AccessPower and Control Wiring Condensate DrainPipe Sizing Disconnect Switch Bracket for UnitsWith Optional BELT-DRIVE Bracket GAS PipingPropane UNITS, Tanks and Piping External SHUT-OFFGAS Connection LOW NOx ApplicationSide Duct Vent and Combustion AIR HoodsOptional Economizer Rain Hood Application ShownPhysical Data Model AIR Flow DEG CFM RPM884 815 925 850 964 880 1001 910 894 885 940 980 1014 1020 1047 1095855 815 903 860 950 905 988 940 1022 970 864 770 908 805 948 835 987 870MIN MAX RLA LRA Static ResistancesBlower Circuit Size Breaker DEG Supply Motor Ampacity FLA AmpsDetail a Utilities Entry DataAIR Flow Legend Detail BPreliminary Operation Cooling OperationCooling System Cooling Sequence of OperationSTART-UP Pilot Checkout Burner AIR Shutter AdjustmentSupply AIR AIR Blower and Temperature Rise Adjustments Burner InstructionsNatural GAS Checking GAS InputGAS Rate Cubic Feet PER Hour Seconds Size of Test Dial For One Cu. ftCleaning Flue Passages and Heating Elements MaintenanceNormal Maintenance StructionsTroubleshooting Troubleshooting