TABLE 8 - SUPPLY AIR PERFORMANCE - 3 & 4 Ton w/Belt-Drive Blower

3 TON - SIDE DUCT CONNECTIONS @ 230/460/575 VOLTS

UNIT

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.20

0.30

0.40

0.50

0.60

0.70

0.80

SIZE

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

843

860

880

925

919

1005

956

1065

993

1145

1030

1195

1067

1235

 

1900

817

775

854

850

893

920

930

995

970

1065

1008

1125

1046

1170

 

1800

790

700

828

760

867

840

906

905

944

980

985

1040

1025

1100

 

1700

-

-

802

670

840

745

881

815

920

900

961

970

1001

1030

036

1600

-

-

-

-

818

665

858

740

898

820

940

890

980

950

 

1500

-

-

-

-

-

-

842

695

882

755

922

835

962

895

 

1400

-

-

-

-

-

-

833

650

867

705

904

765

942

820

 

1300

-

-

-

-

-

-

-

-

858

665

893

725

932

785

 

1200

-

-

-

-

-

-

-

-

847

640

880

680

916

730

 

 

 

 

 

 

 

 

 

 

 

UNIT

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.90

1.00

1.10

1.20

1.30

1.40

1.50

SIZE

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

1103

1270

-

-

-

-

-

-

-

-

-

-

-

-

 

1900

1085

1210

-

-

-

-

-

-

-

-

-

-

-

-

 

1800

1064

1145

1102

1180

-

-

-

-

-

-

-

-

-

-

 

1700

1040

1075

1081

1115

1121

1140

-

-

-

-

-

-

-

-

036

1600

1020

1005

1060

1050

1100

1085

-

-

-

-

-

-

-

-

 

1500

1003

945

1044

995

1086

1035

-

-

-

-

-

-

-

-

 

1400

982

880

1024

920

1067

965

1107

1000

-

-

-

-

-

-

 

1300

970

835

1010

870

1053

920

1099

960

-

-

-

-

-

-

 

1200

953

780

992

815

1034

855

1080

905

-

-

-

-

-

-

NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.

*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.

4 TON - SIDE DUCT CONNECTIONS @ 230/460/575 Volts

UNIT

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.20

0.30

0.40

0.50

0.60

0.70

0.80

SIZE

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

843

860

880

925

919

1005

956

1065

993

1145

1030

1195

1067

1235

 

1900

817

775

854

850

893

920

930

995

970

1065

1008

1125

1046

1170

 

1800

790

700

828

760

867

840

906

905

944

980

985

1040

1025

1100

 

1700

-

-

802

670

840

745

881

815

920

900

961

970

1001

1030

048

1600

-

-

-

-

818

665

858

740

898

820

940

890

980

950

 

1500

-

-

-

-

-

-

842

695

882

755

922

835

962

895

 

1400

-

-

-

-

-

-

833

650

867

705

904

765

942

820

 

1300

-

-

-

-

-

-

-

-

858

665

893

725

932

785

 

1200

-

-

-

-

-

-

-

-

847

640

880

680

916

730

 

 

 

 

 

 

 

 

 

 

 

UNIT

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.90

1.00

1.10

1.20

1.30

1.40

1.50

SIZE

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

1103

1270

-

-

-

-

-

-

-

-

-

-

-

-

 

1900

1085

1210

-

-

-

-

-

-

-

-

-

-

-

-

 

1800

1064

1145

1102

1180

-

-

-

-

-

-

-

-

-

-

 

1700

1040

1075

1081

1115

1121

1140

-

-

-

-

-

-

-

-

048

1600

1020

1005

1060

1050

1100

1085

-

-

-

-

-

-

-

-

 

1500

1003

945

1044

995

1086

1035

-

-

-

-

-

-

-

-

 

1400

982

880

1024

920

1067

965

1107

1000

-

-

-

-

-

-

 

1300

970

835

1010

870

1053

920

1099

960

-

-

-

-

-

-

 

1200

953

780

992

815

1034

855

1080

905

-

-

-

-

-

-

NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.

*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND GAS-FIRED HEAT EXCHANGERS. REFER TO TABLE 8 FOR RESISTANCE VALUES ON CONNECTIONS OTHER THAN SIDE DUCT AIRFLOWS.

10

Unitary Products Group

Image 10
Contents Sunline Installation InstructionSingle Package AIR Conditioners Table of Contents Installation Filters Service AccessPower and Control Wiring Condensate DrainPipe Sizing Disconnect Switch Bracket for UnitsWith Optional BELT-DRIVE Blower GAS PipingPropane UNITS, Tanks and Piping External SHUT-OFFGAS Connection Never USE a FlameVent and Combustion AIR Hoods Optional Economizer Rain Hood2200 2400 2600 10001600 1800 Economizer1 Bottom Duct Connections1Physical Data Center of GravityUnit AIR Flow TON Side Duct Connections @ 230/460/575 VoltsSize CFM RPM 1650 1560 10771095 1630 1660MIN MAX RLA LRA FLA Superheat Charging Table for ModelBlower Circuit Size Breaker Supply Motor Ampacity Amps31.7 18.1 20.1 22.2 24.328.4 34.2 35.4 14.5 16.6 18.7 20.8Utilities Entry Data Knockout Hole Size Used forCooling Sequence of Operation OperationCooling System Heating Sequence of OperationSTART-UP Pilot Checkout Burner AIR Shutter AdjustmentSupply AIR Blower and Temperature Rise Adjustments Burner InstructionsGAS Rate Cubic Feet PER Hour Checking GAS InputNatural GAS Normal Maintenance MaintenanceTroubleshooting Cleaning Flue Passages and Heating ElementsModels only

D2CG 072, D7CG 060, D7CG 048, D7CG 036 specifications

The York D7CG 060, D7CG 048, D7CG 036, and D2CG 072 are advanced rooftop unit models designed for enhanced energy efficiency, reliability, and ease of use in commercial HVAC applications. These models are known for their robust features and technologies aimed at providing optimal indoor climate control.

The D7CG series, including the 060, 048, and 036 models, is built around a highly efficient design. They incorporate scroll compressors that operate quietly, contributing to a comfortable environment. The units are designed for high-ambient performance, enabling them to function efficiently even in extreme temperature conditions. The D7CG series also features an intelligent control system that allows for seamless integration with building management systems, optimizing energy usage and enhancing overall system performance.

One of the standout features of the D7CG models is their advanced heat exchanger technology, which improves heat transfer and overall efficiency. The coil design allows for superior airflow and enhanced temperature regulation, ensuring consistent comfort levels throughout the space. With variable-speed fans, these units adjust airflow dynamically, providing further energy savings and tailored climate control.

The D2CG 072 model, on the other hand, accentuates versatility and robustness. This unit also boasts a high-efficiency compressor and features a unique multi-stage heating and cooling process. Its modular design allows for easy installation and maintenance. The D2CG 072 is engineered for flexible configurations, accommodating various building sizes and layouts without compromising performance.

All four models are equipped with user-friendly digital controls that offer precise adjustments and monitoring capabilities. This feature allows building operators to quickly respond to changing conditions, ensuring optimal comfort for occupants while maintaining energy efficiency. Furthermore, they adhere to stringent environmental standards, incorporating low-GWP refrigerants that minimize their ecological footprint.

In summary, the York D7CG 060, D7CG 048, D7CG 036, and D2CG 072 models represent cutting-edge technology and innovative design in the commercial HVAC sector. Their high efficiency, advanced features, and user-centric controls make them suitable for a wide range of applications, ensuring reliable performance and comfort in diverse environments.