York D7CG 060, D7CG 036, D7CG 048, D2CG 072 Utilities Entry Data, Knockout Hole Size Used for

Page 14

530.18-N8Y

(Direct-Drive Units)

 

 

 

 

 

1112

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1112

 

 

 

 

 

 

 

458

 

 

 

 

 

 

 

 

 

 

 

 

1712

778

 

 

 

 

 

 

 

All dimensions are in inches. They are sub-

 

612

 

 

 

 

 

 

 

ject to change without notice. Certified di-

1712

 

 

 

 

 

 

 

 

 

 

mensions will be provided upon request.

 

 

 

 

 

 

 

SCROLL COMPR.

ACCESS

UTILITIES ENTRY DATA

REAR VIEW

SIDE SUPPLY AND RETURN

DUCT COVERS - Units are shipped with all air duct openings covered.

For side duct applications;

1.Remove and discard the supply and return air duct covers.

2.Connect ductwork to duct flanges on the rear of the unit.

For bottom duct applications;

1.Remove the side supply air duct cover to gain access to the bottom supply air knockout panel.

2.Remove and discard the bottom knockout panel.

3.Replace the side duct cover.

4.With filter section access panel removed from the unit, remove and discard the bottom return air knockout panel.

5.Replace the filter access panel.

AIR FLOW LEGEND

RETURN AIR

SUPPLY AIR

OUTDOOR AIR

OUTDOOR AIR (Economizer)

2712

 

KNOCKOUT

 

HOLE

SIZE

USED FOR

 

(DIA.)

 

A

7/8" *

Control Wiring

(Side or Bottom)**

 

 

B

2" *

Power Wiring

(Side or Bottom)

 

 

C

1-5/8"

Gas Piping (Front)

D

1-1/2"

Gas Piping (Bottom)

*Knockouts in the bottom of the unit can be located by the slice in the insulation.

**Do not remove the 2" knockout ring.

34“ CONDENSATE DRAIN

(must be trapped)

CLEARANCES

Front

32"

 

12" (Less Economizer)

Back

36" (With Economizer or Fixed

 

Air/Motorized Air Damper)

Left Side (Filter Access)

24" (Less Economizer)

36" (With Economizer)

 

Right Side (Cond. Coil)

24"

Below Unit1

0"

Above Unit2

72" (For Condenser Air Discharge)

1934

19124478

DETAIL “A”

UNIT WITH ECONOMIZER RAIN HOOD

1Units may be installed on combustible floors made from wood or class A, B or C roof covering material (Applicable in the U.S.A. only).

2Units must be installed outdoors. Overhanging structures or shrubs should not obstruct the outdoor coil nor the fan outlet.

NOTE: A 1" clearance must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit.

The products of combustion must not be allowed to accumulate within a confined space and recirculate.

Locate unit so that the vent air outlet hood is at least:

Three (3) feet above any forced air inlet located within 10 horizontal feet (excluding those integral to the unit).

Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity air inlet into the building.

Four (4) feet from electric meters, gas meters, regulators and relief equipment.

3078

1918

DIMENSION "A"

FIXED

 

OUTDOOR

12

AIR DAMPER

 

 

 

MOTORIZED

1612

DAMPER

 

 

1014

 

 

B

312

 

A

814

"A"

4478

438

 

DETAIL “B”

 

FIG. 9 - DIMENSIONS AND CLEARANCE (3, 4, 5 & 6 TON)

UNIT WITH FIXED OUTDOOR

AIR/MOTORIZED DAMPER RAIN HOOD

14

Unitary Products Group

Image 14
Contents Single Package AIR Conditioners Installation InstructionSunline Table of Contents Installation Filters Service AccessPower and Control Wiring Condensate DrainPipe Sizing Disconnect Switch Bracket for UnitsWith Optional BELT-DRIVE Blower GAS PipingPropane UNITS, Tanks and Piping External SHUT-OFFGAS Connection Never USE a FlameVent and Combustion AIR Hoods Optional Economizer Rain Hood2200 2400 2600 10001600 1800 Economizer1 Bottom Duct Connections1Physical Data Center of GravitySize CFM RPM TON Side Duct Connections @ 230/460/575 VoltsUnit AIR Flow 1650 1560 10771095 1630 1660MIN MAX RLA LRA FLA Superheat Charging Table for ModelBlower Circuit Size Breaker Supply Motor Ampacity Amps31.7 18.1 20.1 22.2 24.328.4 34.2 35.4 14.5 16.6 18.7 20.8Utilities Entry Data Knockout Hole Size Used forCooling Sequence of Operation OperationCooling System Heating Sequence of OperationSTART-UP Pilot Checkout Burner AIR Shutter AdjustmentSupply AIR Blower and Temperature Rise Adjustments Burner InstructionsNatural GAS Checking GAS InputGAS Rate Cubic Feet PER Hour Normal Maintenance MaintenanceTroubleshooting Cleaning Flue Passages and Heating ElementsModels only

D2CG 072, D7CG 060, D7CG 048, D7CG 036 specifications

The York D7CG 060, D7CG 048, D7CG 036, and D2CG 072 are advanced rooftop unit models designed for enhanced energy efficiency, reliability, and ease of use in commercial HVAC applications. These models are known for their robust features and technologies aimed at providing optimal indoor climate control.

The D7CG series, including the 060, 048, and 036 models, is built around a highly efficient design. They incorporate scroll compressors that operate quietly, contributing to a comfortable environment. The units are designed for high-ambient performance, enabling them to function efficiently even in extreme temperature conditions. The D7CG series also features an intelligent control system that allows for seamless integration with building management systems, optimizing energy usage and enhancing overall system performance.

One of the standout features of the D7CG models is their advanced heat exchanger technology, which improves heat transfer and overall efficiency. The coil design allows for superior airflow and enhanced temperature regulation, ensuring consistent comfort levels throughout the space. With variable-speed fans, these units adjust airflow dynamically, providing further energy savings and tailored climate control.

The D2CG 072 model, on the other hand, accentuates versatility and robustness. This unit also boasts a high-efficiency compressor and features a unique multi-stage heating and cooling process. Its modular design allows for easy installation and maintenance. The D2CG 072 is engineered for flexible configurations, accommodating various building sizes and layouts without compromising performance.

All four models are equipped with user-friendly digital controls that offer precise adjustments and monitoring capabilities. This feature allows building operators to quickly respond to changing conditions, ensuring optimal comfort for occupants while maintaining energy efficiency. Furthermore, they adhere to stringent environmental standards, incorporating low-GWP refrigerants that minimize their ecological footprint.

In summary, the York D7CG 060, D7CG 048, D7CG 036, and D2CG 072 models represent cutting-edge technology and innovative design in the commercial HVAC sector. Their high efficiency, advanced features, and user-centric controls make them suitable for a wide range of applications, ensuring reliable performance and comfort in diverse environments.