Sterling SDAA 25-100 specifications Process Air Temperature Controller

Models: SDAA 25-100

1 60
Download 60 pages 53.38 Kb
Page 27
Image 27

Process Air Temperature Controller

Our dryers use a microprocessor-based PID temperature controller for maintaining process air temperature. The controller is a modular, self-contained unit you can remove from the mounting housing. All parameters except for the process air set point are factory set and adjusted; normally, no field adjustment to the internal controls is necessary.

Figure 5: Typical Process Air Temperature Controller

PV

SV

Identifying Process Air Temperature Controller LED Indicators

 

Indicator

Name

Description

 

 

 

 

 

 

 

PV

Process Value

During normal operation, the process value (PV)

 

 

 

 

Numeric LED

numeric LED indicator displays the process

 

8.8.8.8

 

 

 

 

temperature at the To Process thermocouple. It

 

 

 

 

 

 

 

 

 

 

also lists parameters during setup and error

 

 

 

 

 

messages if any errors occur.

 

 

 

 

 

SV

Set Value

During normal operation, the set value (SV)

 

 

 

 

Numeric LED

numeric LED indicator displays the process set

 

8.8.8.8

 

 

 

 

 

 

point temperature selected for the dryer. The dryer

 

 

 

 

 

 

 

 

 

 

then maintains this set point temperature. This

 

 

 

 

 

LED indicator also displays parameter and pre-set

 

 

 

 

 

function values during configuration setup.

 

 

 

 

 

OUT1

Out 1 LED

Lit when Control Output 1 is on. The Out1

 

 

 

 

 

indicator lights when the controller signals the

 

 

 

 

 

process heaters to be energized.

 

 

 

 

 

OUT2

Out 2 LED

Lit when Control Output 2 is on. Not used in

 

 

 

 

 

this application.

 

 

 

 

 

AT

AT LED

Flashes during auto-tuning in process value (PV)

 

 

 

 

 

screen.

 

 

 

 

 

 

Dehumidifying Dryers

Chapter 4: Operation

26 of 59

Page 27
Image 27
Sterling SDAA 25-100 specifications Process Air Temperature Controller, Lit when Control Output 1 is on. The Out1