Sterling SDAA 25-100 Process Air Dew Point Display, Optional, Setting the High Dew Point Alarm

Models: SDAA 25-100

1 60
Download 60 pages 53.38 Kb
Page 32
Image 32

Process Air Dew Point Display

Optional

The Process Air Dew Point meter indicates the current process air delivery moisture content. Standard dryers use a microprocessor-based controller for displaying dew point air temperature. The controller is a modular, self-contained unit removable from the mounting housing. All parameters are factory set and adjusted; normally, no field adjustment to the internal controls are necessary.

Figure 7: Typical Dew Point Display Monitor

PV

SV

OUT1

OUT2 MANU STOP RMT AT

SUB1

AT

OMRONE5CK

Note: The only functional buttons on this contoller are the up and down keys.

Setting the High Dew Point Alarm

The high dew point alarm setting is changed by pressing the up and down keys to input the alarm value. The factory setting for Alarm Value 1 (AL-1) is -10°F (-23°C).

Restoring the Process Air Dew Point Meter (E5CK) to Factory Setup

If the preset parameters on the controller have been tampered with and it no longer functions properly, call the Service Department. This controller is not meant to be modified.

Note: The dew point alarm monitors and indicates a deviation from the set point.

Dehumidifying Dryers

Chapter 4: Operation

31 of 59