NFPA79 machinery electrical standards

Non-fused electrical disconnect

Branch fusing

Mercury process heater contactor

Regeneration temperature control

Process high temperature alarm light

Process/regeneration heater box

High temperature safety system (Process/Regeneration)

Dew point monitor with digital read-out

Controller Features

Mitsubishi programmable relay controller

Display of process temperature set point and actual settings

2-4 Options

Options marked with “*” indicate options that can be factory installed or retrofitted in the field.

*Process temperature 180ºF to 400˚ F, including aftercooler inside dryer and silicone insulated delivery hose.

*Process temperature 120˚ F to 250˚ F, includes precooler on back of dryer.

*If the dryer is a central dry air generator, it will not have a process heater box.

*Plasticizer trap (with cooling coil) in lieu of optional aftercooler (mounts outside on back of dryer).

*Machine mount adapter to accommodate a dryer and corresponding hopper.

*Drawer magnet, stainless steel construction.

*Casters, two (2) fixed and two (2) swivel.

*Cart with caster with hopper mounting place.

*Redundant high temp safety control.

*Audible alarm

*Insulated air hose for air delivery

2-5 Safety Devices and Interlocks

This section includes information on safety devices and procedures that are inherent to the Dryer. This manual is not intended to supersede or alter safety standards established by the user of this equipment. Instead, the material contained in this section is recommended to supplement these procedures in order to provide a safer working environment.

At the completion of this section, the operator and maintenance personnel will be able to do the following:

Dehumidifying Dryers

Chapter 2: Functional Description

13 of 59

Page 14
Image 14
Sterling SDAA 25-100 specifications Options, Safety Devices and Interlocks, Controller Features