Sterling SDAA 25-100 specifications Determining Temperature Controller Errors or Sensor Errors

Models: SDAA 25-100

1 60
Download 60 pages 53.38 Kb
Page 52
Image 52

 

Problem

 

Possible cause

 

Corrective action

 

 

 

 

 

 

 

No setting change possible on

 

The key protection switch is set

 

Set the key protection switch to

 

temperature controller.

 

to ON.

 

OFF.

 

 

 

 

Input polarity on thermo-couple

 

Properly wire the terminals.

 

 

 

is wrong or connection is wrong.

 

 

 

 

 

 

 

 

 

 

 

 

Properly set the input with the

 

 

 

Input-type setting is incorrect.

 

input-type selector rotary

 

 

 

 

 

switch.

 

 

 

 

No compensating lead wires

 

Use proper compensating lead

 

 

 

used for extension of the

 

 

 

 

 

wires and terminals.

 

 

 

thermocouple.

 

 

 

 

 

 

 

 

 

 

 

 

Use a dedicated thermocouple

 

 

 

Thermocouple and controller are

 

connector. If a connector is a

 

 

 

connected by wires other than

 

metal different from the

 

 

 

proper lead wires.

 

thermocouple and controller, a

 

Process value is abnormal or

 

 

 

temperature error may result.

 

not obtained.

 

Process thermocouple not in

 

Verify that the thermocouple is

 

 

 

 

properly installed in the inlet

 

 

 

airflow.

 

 

 

 

 

tube.

 

 

 

 

 

 

 

 

 

 

Sensor is broken or short-

 

Replace with a good sensor.

 

 

 

circuited.

 

 

 

 

 

 

 

 

 

 

The controller is influenced by

 

Separate input wires as far as

 

 

 

 

possible from the origin of the

 

 

 

noise or other induction.

 

 

 

 

 

noise.

 

 

 

 

 

 

 

 

 

 

Celsius temperatures used

 

Check Mode selector switch 6:

 

 

 

instead of Fahrenheit or vice

 

ON - ºF

 

 

 

versa.

 

OFF - ºC

 

 

 

Process value shifted because

 

Set input shift value to 0, or set

 

 

 

the input shift function is used.

 

mode selector switch 4 to OFF.

6-2 Determining Temperature Controller Errors or Sensor Errors

Using a Thermocouple

If the controller displays a temperature that is close to room temperature (70ºF/21ºC) when you short-circuit controller input terminals, the controller is normal and the sensor is probably broken, short-circuited, or incorrectly wired.

Using a Platinum Resistance Thermometer

If the controller displays a temperature of about 0.0°C (32ºF) when you insert a 100-ohm resistor between terminals A and –Bof the controller, and you short-circuit controller terminals +B and –B, the controller is normal and the sensor is probably broken, short- circuited, or incorrectly wired.

Other service problems or questions can be answered by contacting the Service Department.

Dehumidifying Dryers