Problem

 

Possible cause

 

Corrective action

 

 

 

 

 

 

 

 

 

 

 

Check resin manufacturer’s data

 

 

 

Process temperature set too high

 

sheet for proper drying

 

 

 

 

temperature. Make sure plant

 

 

 

due to operator error.

 

personnel are aware of the

 

 

 

 

 

correct process temperature set

 

 

 

 

 

point.

 

 

 

High temperature alarm not set

 

Reset high temperature alarm.

 

Material in drying hopper cakes,

 

properly.

 

 

 

 

 

 

or meltdown occurs.

 

Process set point is out of

 

Restore temperature controller

 

 

 

acceptable range.

 

to factory pre-sets.

 

 

 

Function set for degrees Celsius

 

Verify correct Celsius or

 

 

 

(ºC), set point at degrees

 

 

 

 

 

Fahrenheit settings.

 

 

 

Fahrenheit (ºF).

 

 

 

 

 

 

 

 

 

Process thermocouple not in

 

Verify that the thermocouple is

 

 

 

 

properly installed in the inlet

 

 

 

airflow.

 

 

 

 

 

tube.

 

 

 

 

 

 

 

 

Burned out regeneration heater.

 

Repair or replace.

 

 

 

Contaminated or worn out

 

Replace.

 

 

 

desiccant.

 

 

 

 

 

 

 

 

 

Leaking process air hoses.

 

Repair or replace.

 

Poor dew point performance.

 

Dryer operates beyond its

 

Check dryer and drying hopper

 

 

capacity.

 

sizing.

 

 

 

 

 

 

 

Bad dew point sensor.

 

Replace.

 

 

 

Fouled dew point sensor

 

Clear obstruction. Air should

 

 

 

manifold.

 

flow freely through sensor.

 

 

 

Dirty filter.

 

Clean or replace filter element.

 

 

 

The internal mechanism is not

 

Properly insert the internal

 

 

 

inserted properly into the

 

 

 

 

 

mechanism into the housing.

 

 

 

housing.

 

 

 

 

 

 

 

 

 

The power supply is not

 

Properly connect the power

 

 

 

connected to its terminals

 

supply to the power supply

 

Nothing displays when the

 

properly.

 

terminals.

 

 

No power is supplied, or the

 

Supply a voltage of 85 to 125

 

controller is turned on.

 

 

 

 

supplied power is not within the

 

VAC to the power supply

 

 

 

 

 

 

 

specified range.

 

terminals of the controller.

 

 

 

Disconnect switch or Control

 

Check control power fuse for

 

 

 

 

continuity. Turn disconnect

 

 

 

Power switch not set to ON.

 

 

 

 

 

switch and control power switch

 

 

 

Control Power fuse blown.

 

 

 

 

 

ON.

 

 

 

 

 

Dehumidifying Dryers

Chapter 6: Troubleshooting

50 of 59

Page 51
Image 51
Sterling SDAA 25-100 specifications Check resin manufacturer’s data