HP 370971-004 manual Creating script files, Cpqacuxe /C A\PL-RD.INI

Page 10

This command reads the current configuration on the source server and writes the hardware configuration data file to A:\HWCONFIG.XML.

2.Generate the array configuration data file with the following command:

CPQACUXE /C A:\PL-RD.INI

This command reads the array configuration on the source server and writes the array configuration data file to A:\PL-RD.INI.

3.Create the partition configuration data file. A sample DISKPART0.TXT file is provided with the Toolkit in the samples directory. For more information on using DISKPART, refer to the Microsoft® documentation.

4.If needed, create the RILOE II or iLO configuration data file. For examples of the command line parameters, refer to the "Using HPONCFG" section of the HP SmartStart Scripting Toolkit Linux and Win32 Editions User Guide.

Use a text editor as necessary to make changes to the configuration files so that they conform to the target server.

Now, data files can be captured and stored in either of the following ways:

Capturing and storing data files using physical media (on page 10)

Capturing data files over a network (on page 10)

Capturing and storing data files using physical media

HP SmartStart Scripting Toolkit utilities and scripts can be stored on physical media, such as a diskette or a driverless USB storage device.

NOTE: Windows® PE supports USB natively, but USB devices must be connected to the system before Windows® PE boots to be recognized. Be sure the proper device driver is loaded if you are using a non- driverless USB device for storage.

After Windows® PE boots, you can execute the utilities to capture data files and store them on the USB storage device. These data files can then be modified as needed and used for deploying configurations on other systems.

Capturing data files over a network

For Windows® PE to support network access, the driver for the networking device must be on the Windows® PE image. To update drivers to the Windows® PE image, refer to "Microsoft Windows Preinstallation Environment (on page 5)."

Windows® PE does not support access to files or folders on Windows® PE servers from another location on the network.

After Windows® PE boots, you can access files and folders stored on other servers on the network. Map the proper drive to the file server where the utilities are stored and the data files will reside, and execute the utilities to capture data files. These data files can then be modified as needed and used for deploying configurations on other systems.

Creating script files

After the server data files are generated and modified for the target server, modify and save a copy of the script files to the appropriate location. Refer to the operating system documentation for a complete description of the options that can be modified in the unattended installation file to customize the installation.

Using a standard text editor, create the following additional Toolkit files for the unattended install.

Configuring HP ProLiant systems with Windows PE 10

Image 10
Contents HP SmartStart Scripting Toolkit Win32 Edition Best Practices Page Contents Toolkit changes IntroductionWin32 Toolkit overview Minimum requirementsMicrosoft Windows Preinstallation Environment Windows PE build processXcopy /s /e PathToWinPEFiles\WinPE\*.* WinPEBuildTools Booting Windows PE from a USB drive key Overview of configuring HP ProLiant systems with Windows PE Configuring HP ProLiant systems with WindowsUnattended configuration using startnet.cmd Conrep /S A\HWCONFIG.XML Creating required data files with Windows PECreating script files Cpqacuxe /C A\PL-RD.INIREM Goto NEXT6 NEXT3 Goto NEXT6 NEXT1Goto NEXT6 NEXT2 Goto NEXT6 NEXT4NEXT5 State4 ADPU160M.SYS CPQARRY2.SYS CPQCISSM.SYSTXTSETUP.OEM SNMP=1 WBEMSNMP=1CD-based Windows PE deployment Startdeploy.cmdPXE-based Windows PE deployment Network-based Windows PE deploymentConfiguring HP ProLiant systems with Windows PE Toolkit support Technical supportReference documentation HP contact informationAcronyms and abbreviations WDM Index