HP 288048 manual Install Air Fittings, Ground System

Page 6

Installation

Install Air Fittings

1.Install 1/4 in. tube fitting into the cylinder (CYL) air port.

2.Install plugs into the atomization (ATOM) air port and the fan (FAN) air port.

CYL

ATOM

FANTI8225a

FIG. 2: Air Fittings

Ground System

The following grounding instructions are minimum requirements for a system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.

Ground Pump

Ground the pump by connecting a ground wire and clamp between the fluid supply and a true earth ground as instructed in your separate pump instruction manual.

Ground Air Compressors and Hydraulic Power Supplies

Ground them according to the manufacturer recommen- dations.

Ground Air, Fluid, and Hydraulic Hoses Connected to Pump

Use only electrically conductive hoses with a maximum of 100 ft (30.5 m) combined hose length to ensure grounding continuity. Check the electrical resistance of your air and fluid hoses at least once a week. If the total resistance to ground exceeds 25 megohms, replace the hose immediately.

Use a meter that is capable of measuring resis- tance at this level.

Ground Spray Gun

Ground the spray gun by connecting it to a properly grounded fluid hose and pump.

Ground Fluid Supply Container

Ground the fluid supply container according to local code.

Ground Object Being Sprayed

Ground the object being sprayed according to local code.

Ground Solvent Pails

Ground all solvent pails that are used with flushing according to local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

6

311053C

Image 6
Contents Automatic Airless Spray Guns Model 288048 ShownContents Related ManualsEquipment Misuse Hazard Pressurized Equipment Hazard Configure Gun and Manifold InstallationVentilate Spray Booth Non-circulating SystemInstall Air Fittings Ground SystemStationary Support Mount Mount GunReciprocating Arm Rod Mount All ManifoldsSetup Manifolds 288219 KEYAdjust a Streaming Tip Install Spray TipAdjust Spray Pattern Flush Spray GunApply the Fluid Pressure Relief ProcedureOperation IncorrectDaily Gun Care Daily Flushing Procedure General System MaintenanceDaily Cleaning Procedure Perform Pressure Relief Procedure,Troubleshooting General TroubleshootingProblem Cause Solution Problem Cause Solution Spray Pattern Troubleshooting Service DisassemblyService Notes Reassembly Parts Model11† Ref. only TIP see GG0 Series Tip Selec Tion Charts, PartsPart No. Description Qty Description Qty North America and International ManifoldGG0 Series Tip Selection Charts GG0 Series Spray TipsStreaming Tips Sealer Application Tip and Air Cap Selection ChartsShower Tip Single Orifice Fan Pattern Spray TipsAccessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutTriggering Speed Technical DataSound Power Levels dBa Sound Pressure Levels dBaGraco Standard Warranty Graco Information