York B1CH180, B1CH240 Electrical Data Basic Units, Motor Supply, Fuse Size FLA RLA LRA Amps Each

Page 14

511.06-N3Y

TABLE 11 - ELECTRICAL DATA (BASIC UNITS)

 

 

 

COMPRESSORS

OUTDOOR FAN

 

SUPPLY AIR

MINIMUM

MAXIMUM

 

 

 

 

 

 

 

 

 

 

MOTORS

 

BLOWER

 

 

POWER

 

#1

 

#2

 

CIRCUIT

TIME DELAY

 

MODEL

 

 

(#1 & #2)

 

 

MOTOR

 

SUPPLY

 

 

 

 

 

 

 

 

AMPACITY

FUSE SIZE

 

 

 

 

 

 

 

 

HP

 

FLA

 

 

 

 

 

 

 

 

 

RLA

LRA

RLA

LRA

 

HP

 

FLA

(AMPS)

(AMPS)

 

 

 

 

EACH

 

EACH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-3-60

 

28.2

 

260

28.2

260

1

 

4.1/4.2

5

 

14.4/15.4

86.1/87.3

110

 

 

 

B1CH180

460-3-60

 

14.1

 

128

14.1

128

1

 

2.1

5

 

7.2

 

43.1

50

 

 

 

 

575-3-60

 

11.5

 

104

11.5

104

1

 

2.0

5

 

5.9

 

35.9

45

 

 

 

 

208/230-3-60

 

33.3

 

300

33.3

300

1

 

4.1/4.2

7.5

 

19.4/21.0

102.6/104.4

125

 

 

 

B1CH240

460-3-60

 

19.2

 

146

19.2

146

1

 

2.1

7.5

 

9.7

 

57.2

70

 

 

 

 

575-3-60

 

12.8

 

124

12.8

124

1

 

2.0

7.5

 

7.8

 

40.6

50

 

 

 

*Although these sizes are based on copper conductors, aluminum wire can be used.

 

 

 

 

 

 

 

 

 

 

 

 

Refer to the National Electric Code ( in U.S.A.) or the current Canadian Electrical Code

 

 

 

 

 

 

 

 

 

 

 

 

(in Canada) to determine the proper size.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

MIN.

 

MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-3-60

 

187

 

 

253

 

 

 

 

 

 

 

 

 

 

 

 

LIMITATIONS**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-3-60

 

414

 

 

506

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575-3-60

 

518

 

 

630

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**Rated in accordance with ARI Standard 110, utilization range "A".

TABLE 12 - ELECTRICAL DATA (UNITS w/SUPPLEMENTAL ELECTRIC HEAT)

 

 

 

HEATER OPTION

 

MINIMUM

MAXIMUM

MODEL

POWER

 

KW1

 

 

CIRCUIT

TIME DELAY

B1CH

SUPPLY

MODEL

STAGES

AMPS

AMPACITY

FUSE SIZE

 

 

 

 

 

 

(AMPS)

(AMPS)

 

 

E018

13.5

1

37.5

133.0

150

 

208-3-60

E036

27.0

2

75.1

133.0

150

 

E054

40.6

2

112.6

179.9

200

 

 

180A25

 

E072

54.1

2

150.1

179.9

200

 

E018

18.0

1

43.3

141.4

150

 

 

 

230-3-60

E036

36.0

2

86.6

141.4

150

 

E054

54.0

2

129.9

195.5

200

 

 

 

 

E072

72.0

2

173.2

195.5

200

 

 

E018

18.0

1

21.7

70.2

80

180A46

460-3-60

E036

36.0

2

43.3

70.2

80

E054

54.0

2

65.0

97.3

100

 

 

 

 

E072

72.0

2

86.6

97.3

100

 

 

E018

18.0

1

17.3

57.5

60

180A58

575-3-60

E036

36.0

2

34.6

57.5

60

E054

54.0

2

52.0

79.2

80

 

 

 

 

E072

72.0

2

69.3

79.2

80

 

 

E018

13.5

1

37.5

149.5

150

 

208-3-60

E036

27.0

2

75.1

149.5

150

 

E054

40.6

2

112.6

196.4

200

 

 

240A25

 

E072

54.1

2

150.1

212.7

225

 

E018

18.0

1

43.3

158.5

175

 

 

 

230-3-60

E036

36.0

2

86.6

158.5

175

 

E054

54.0

2

129.9

196.4

200

 

 

 

 

E072

72.0

2

173.2

212.7

225

 

 

E018

18.0

1

21.7

84.2

90

240A46

460-3-60

E036

36.0

2

43.3

84.2

90

E054

54.0

2

65.0

111.3

125

 

 

 

 

E072

72.0

2

86.6

111.3

125

 

 

E018

18.0

1

17.3

62.3

70

240A58

575-3-60

E036

36.0

2

34.6

62.3

70

E054

54.0

2

52.0

83.9

90

 

 

 

 

E072

72.0

2

69.3

83.9

90

1Electric Heat CORRECTION FACTORS:

NOMINAL VOLTAGE

VOLTAGE

KW CAP. MULTIPLIER

208

208

1.00

240

230

0.92

480

460

0.92

600

575

0.92

2Although these sizes are based on copper conductors, aluminum wire can be used. Refer to the National Electric code ( in U.S.A.) or the current Canadian Electrical Code (in Canada) to determine the proper size.

14

Unitary Products Group

Image 14
Contents Sunline 2000 Single Package Heat Pumps Table of Contents Installation Fixed Outdoor AIR Intake Damper Service AccessPower and Control Wiring Condensate DrainTypical Field Wiring Control Wire SizesOptional Electric Heaters Power EXHAUST/BAROMETRIC Relief Damper and Rain Hood OptionEnthalpy SET Point Adjustment Electric Heat Application DataEnthalpy Setpoint Adjustment Physical Data Opening Hole Size Used for Utilities Entry DataReturn AIR Supply AIR Outdoor AIR Point Loads Unit Point Loads LBSBlower Motor CFM Pulley Speed Turns RPM ESP BHP OpenSpeed RPM Turns ESP BHP Open Blower Motor and Drive Data Power Exhaust PerformanceStatic Resistances Fuse Size FLA RLA LRA Amps Each Electrical Data Basic UnitsMotor Supply Fuse SizePreliminary Operation Cooling OperationCooling System Cooling Sequence of OperationHeat Anticipator Setpoints Heat Anticipator SettingHeater Voltage SETTING, Amps TH1 TH2 Checking Supply AIR CFMDefrost Sequence of Operation Lockout ControlT2 80 Minute Setting T3 110 Minute Setting MaintenanceNormal Maintenance Motors511.06-N3Y Unitary Products Group

B1CH240, B1CH180 specifications

The York B1CH240 and B1CH180 are two prominent models in the commercial HVAC (Heating, Ventilation, and Air Conditioning) sector, known for their efficiency and reliability in demanding environments. Both units are designed with the latest technologies to provide optimal climate control, making them suitable for a variety of applications including offices, retail spaces, and industrial environments.

One of the main features of the York B1CH series is its high energy efficiency. These models are equipped with advanced inverter technology, allowing them to adjust their cooling and heating output based on the current demand. This not only minimizes energy consumption but also reduces operating costs, making them an environmentally friendly choice. The units also meet or exceed industry standards for energy efficiency, complying with stringent regulations set forth by organizations such as ASHRAE and ENERGY STAR.

Another key characteristic of the B1CH240 and B1CH180 is their adaptability. These units come with customizable settings and programmable controls, enabling users to optimize performance based on specific needs. Whether it is cooling an entire building or maintaining comfortable temperatures in different zones, the B1CH series can be tailored to fit the unique demands of any space.

In terms of technology, York has integrated advanced refrigerant management into the B1CH series. The units utilize R-410A refrigerant, which not only enhances cooling efficiency but also minimizes environmental impact. This refrigerant is known for its higher performance and lower toxicity compared to traditional options, aligning with global efforts to reduce ozone depletion.

Durability is another hallmark of the York B1CH240 and B1CH180 models. Constructed from high-quality materials, these units are designed to withstand the rigors of everyday use while maintaining peak performance. The units are also equipped with comprehensive diagnostic and monitoring systems that alert users to any potential issues before they escalate, ensuring uninterrupted operation and reducing maintenance downtime.

Moreover, the B1CH series features a quiet operation mode, making them ideal for noise-sensitive environments. The design incorporates sound-dampening materials and efficient airflow dynamics to ensure that the units operate at a low noise level while providing powerful heating and cooling.

In summary, the York B1CH240 and B1CH180 models stand out in the HVAC market for their energy efficiency, adaptability, advanced refrigerant management, durability, and quiet operation. Together, these features make them an excellent choice for businesses seeking reliable and cost-effective climate control solutions. Whether for new construction or retrofitting existing spaces, these units are poised to meet the diverse needs of commercial and industrial applications.