5.The seals and gaskets on the doors floors and ports should be inspected for adequate sealing. Remove any foreign materials that may be embedded in the gasket. Worn or damaged gasket should be replaced.

6.Check all the fasteners on the system and tighten if necessary.

Maintenance Tasks to be Performed Every Three Months:

1.Measure and record the resistance of the heater. Changes in these measurements over time can help predict any future heater elements failing.

Maintenance Tasks to be Performed on an Annual Basis:

1.Calibrate the Watlow controller.

2.Inspect seats of solenoid valve. Chart recommends replacing the valve as a preventative maintenance measure against thermal run-away conditions due to solenoid valve failure.

15

Image 20
Contents Chart INDUSTRIES, INC Isis Chamber USER’S Manual Service OverviewSafety First Chart Environmental Chambers Overview Table of Contents List of Tables Safety Information Description of Safety Features Specifications and Utility Requirements M p e r a t u r eFeatures Watlow Series 96 temperature controller System Installation Chart Environmental Chambers System Installation Chart Environmental Chambers System Installation Operation Chart Environmental Chambers Operation Entering Temperature Set Points Heating/Cooling Indicators System Maintenance Chart Environmental Chambers System Maintenance Replacement Parts Warranty