HP Thunderbolt 2-Port AiO Module ESXi/ESX manual Introduction

Page 9

BladeSystem c-Class IO Accelerators have two distinct designs for the respective server product lines. The G1 through G7 IO Accelerator adapter is provided in a c-Class Type 1 Mezzanine card form factor. It can be installed in both Type 1 and Type 2 mezzanine slots within the c-Class blade G1 through G7 servers, enabling a total of two cards in a half-height server blade, and three cards in a full-height server blade and up to 6 in a double-high, double-wide server (BL680c).

The Gen8 adapter is provided in a c-Class Type B Mezzanine card form factor. It can only be installed in Type B mezzanine slots within the Gen 8 or later servers, enabling one IO Accelerator in a half-height Gen8 server.

The Type I mezz card and the Type B mezz card are distinguished by the mezzanine connector. The type B card is slightly larger than a Type I mezz card.

The amount of free RAM required by the driver depends on the size of the blocks used when writing to the drive. The smaller the blocks, the more RAM is required. The table below lists the guidelines for each 80GB of storage. For the latest information, see the QuickSpecs sheet to the HP IO Accelerator for HP BladeSystem c-Classat HP Customer Support (http://www.hp.com/support).

The Remote Power Cut Module for the c-Class blade mezzanine card provides a higher level of protection in the event of a catastrophic power loss (for example, a user accidentally pulls the wrong server blade out of the slot). The Remote Power Cut Module ensures in-flight writes are completed to NAND flash in these catastrophic scenarios. Without the Remote Power Cut Module, write performance is slower. Writes are not acknowledged until the data is written to the NAND module, thereby slowing performance. When the Remote Power Cut Module is installed, writes are acknowledged by the IO Accelerator controller to the driver. The IO Accelerator controller then completes the write to the NAND module.

The IO Accelerators (QK761A, QK762A, and QK763A) for Gen 8 BladeSystem c-Class have the power cut functionality embedded on the card. They offer the protection without requiring the remote power cut module.

NOTE: The Remote Power Cut Module is used only in the AJ878B and BK836A models. Without the Remote Power Cut Module, write performance is slower.

HP PCIe IO Accelerator minimum requirements

An open PCI-Express slot—The accelerator requires a minimum of one half-length, half-height slot with a x4 physical connector. All four lanes must be connected for full performance. HP PCIe IO Accelerator Duo requires a minimum of a full-height, half-length slot with an x8 physical connection. If your system is using PCI 1.1, all x8 signaling lanes must be connected for full performance. If your system is using PCI 2.0, for full performance you only have to connect x4 signaling lanes.

NOTE: For PCIe IO Accelerators, using PCIe slots greater than x4 does not improve performance.

NOTE: The power cut feature is built into PCIe IO Accelerators; therefore, no Remote Power Cut Module is necessary.

300 LFM of airflow at no greater than 50°C. To protect against thermal damage, the IO Accelerator also monitors the junction temperature of its controller. The temperature represents the internal temperature of the controller, and it is reported in fio-statusreport. The IO Accelerator begins throttling write performance when the junction temperature reaches 78°C. If the junction temperature continues to rise, the IO Accelerator shuts down when the temperature reaches 85°C.

NOTE: If you experience write performance throttling due to high temperatures, see your computer documentation for details on increasing airflow, including fan speeds.

Introduction 9

Image 9
Contents Abstract Page Contents Module parameters About this guide Contents summaryIntroduction OverviewProduct naming Required operating environment Performance attributesSupported hardware Supported firmware revisionsIntroduction Before you begin Introduction Command-line installation Software installationESX command-line installation ESXi command line installationInstallation overview Downloading the VMware ESXi driverIomemory-vsl-version.zip Vmfs/volumes/datastore/bundles Transferring the VSL files to the ESX or ESXi serverVifs.pl --server servername --mkdir datastorebundles Installing the VSL on ESX or ESXi Installing the VSL on ESXiInstalling the VSL on ESXi 5.0 using vCLI Installing the VSL on ESXi 5.0 using the command-lineInstalling the VSL on ESX or ESXi 4.x using vCLI Upgrading the firmware using ESXUpgrading device firmware from VSL 1.x.x or 2.x.x to Upgrading procedureFio-bugreport Iomemory-vsl block driver for ESXiIomemory-vsl block driver for ESX/ESXi Enabling PCIe power Configuring the device to support VM disksFio-update-iodrive iodriveversion.fff Modifying a VMware resource pool to reserve memory Using the IO Accelerator as swap with ESX Maintenance tools MaintenanceCommand-line utilities for Tech Support Mode Management utilities for ESXiCommand line Purpose Utility Enabling PCIe power overrideEnabling the override parameter Disabling the driver Common maintenance tasksEnabling the driver 1149D0969,1159E0972,24589Disabling auto attach Uninstalling the IO Accelerator driver packageEnabling auto attach # esxcfg-module -s autoattach=1 iomemory-vslUnmanaged shutdown issues Introduction to performance and tuning Performance and tuningDisabling Dvfs Limiting Apci C-statesUtilities Utilities referenceFio-attach Fio-bugreport Fio-beaconFio-attach device options Fio-beacon device optionsFio-bugreport Fio-detach Fio-formatFio-detach device options Fio-format options device Fio-pci-checkFio-status Fio-pci-check optionsFio-status device options Utilities Geometry and capacity information not available appears Fio-update-iodriveFio-update-iodrive options iodriveversion.fff Utilities Nand flash and component failure Monitoring IO Accelerator healthHealth metrics Health monitoring techniquesFlashback substitution events Using module parameters Module parametersEsxcfg-module --server server-name iomemory-vsl -g Using products with multiple devices VMDirectPathIOWorking with IO Accelerators and VMDirectPathIO Subscription service ResourcesFor more information Before you contact HP Support and other resourcesHP contact information Customer Self RepairRéparation par le client CSR Riparazione da parte del cliente Reparaciones del propio cliente Reparo feito pelo cliente Support and other resources Support and other resources Support and other resources Regulatory compliance notices Regulatory compliance identification numbersEuropean Union regulatory notice Korean class a notice Acronyms and abbreviations Vmdk Documentation feedback Index Index