Assembly of Furnace

Your furnace requires the following items to be assembled or installed by the service person:

BLOWER AND BLOWER CONTROLS

ELECTRICAL CONNECTIONS

1. Remove all parts from inside the furnace and inspect for damage. Including the firebrick, as some damage could have occurred during shipment.

2. Place base assembly in area where furnace will be installed, and place furnace on base as shown in Figure 8. Be certain furnace fits inside tabs as shown.

3. Install Honeywell Fan/Limit Control on rear of cabinet as shown in Fig. 8. NOTE: Remove cover of Fan/Limit control for access to screw holes.

4. Remove blower from carton and inspect for damage. Remove cover from 4" junction box on rear of furnace. (See Fig. 8)

5. Attach clip nuts to blower opening on rear of furnace as shown. Install blower and gasket using 1/4-20x3/4" bolts provided.

6. Complete all wiring in 4" junction box by reference to wiring diagram, Fig. 9, Page 11. After wiring is completed, remember to replace junction box cover.

Fig. 8

Honeywell

FAN/LIMIT

CONTROL

4" ELECTRICAL JUNCTION BOX

BLOWER

ASSEMBLY

CLIP NUTS

GASKET

NOTE: DO NOT USE CLIP NUT OR BOLT ON UPPER CENTER HOLE

10

Image 10
Contents Assembly Installation Operation Repair Parts Do not USE this Furnace in a Mobile Home or TrailerCongratulations EnergySafety Notice Rules for safe installation and operation How The Furnace Functions Dimensions Locating the Furnace Masonry Chimney Chimney ConnectionListed Factory Built Chimney Rules for Connector Pipe Installation Adjusting the Barometric Draft Regula- torAssembly of Furnace Blower and Blower Controls Electrical ConnectionsModel 1303 Wiring Diagram Installation Repair Parts List Model KEY Description QTYModel 1303 See Repair Parts List on Power Failure Instructions Central Installation Operating Instructions LightingService Hints Chimney MaintenanceList of Problems Possible Cause Solutions Appendix Installation B Installation E Installation F United States Stove Company