Trouble Shooting Tips for Warm Air Furnace
LIST OF PROBLEMS | POSSIBLE CAUSE | SOLUTIONS |
1. Smoking when feed door is | a) Insufficient Draft. | a) Set thermostat higher. |
open. | b) Clogged chimney or chimney | b) Clean chimney. |
| connector. | c) Add raincap to chimney. |
| c) Down draft in chimney |
|
|
|
|
2. Furnace does not heat. | a) Wood not seasoned and dry. | a) Allow wood to season in a dry, |
|
| well ventilated area for 6 mo. |
| b) Blower control set too low. | b) Set blower control to higher |
| c) Insufficient flue draft. | temperatures. |
|
| c) Set flue draft. (See page 9) |
|
|
|
3. Blower does not run. | a) Improperly wired. | a) Wire unit properly. |
| b) Bad blower control. | b) Replace blower control. |
| c) Bad relay. | c) Replace relay. |
| d) Bad blower motor. | d) Replace blower. |
|
|
|
4. No air from registers- | a) Registers are closed. | a) Open registers. |
fan running. | b) Duct work improperly installed. | b) Correct duct work installations. |
| c) Improper wiring between cen- | c) Wire unit properly. |
| tral furnace and Model 1303. |
|
|
|
|
5. Air from registers is not hot. | a) Blower control is set too low. | a) Adjust blower control to |
|
| higher setting. |
| b) Bad blower control. | b) Replace blower control. |
|
|
|
6. Blower runs too long. | a) Blower control | a) Set blower control |
| low. | to higher setting. |
|
|
|
7. Blower does not run long | a) Blower control | a) Set blower control |
enough. | high. | lower setting. |
| b) Bad blower motor. | b) Replace blower. |
|
|
|
8. Smoke and/or odor from | Oil from furnace and duct work. | The metal used in construction |
registers when furnace is |
| of the furnace and duct work has |
used for first time. |
| a light coating of oil. This should |
|
| disappear after a short period of |
|
| time. Once this |
|
| curred, it should not reoccur. |
|
|
|
9. Creosote buildup. | a) Burning green wood(not | a) Burn only seasoned wood. |
| seasoned or dry). |
|
| b) Thermostat setting too low for | b) Set thermostat higher to at- |
| type fuel. | tain higher flue temperatures. |
|
|
|
10. Flame spillage when feed | a) Insufficient draft. | a) Set thermostat higher. |
door is open. | b) Smothering fire when adding | b) Add fuel so as not to |
| fresh fuel. | smother fire. |
|
|
|
19