PART B FIGURE 8 -

(FIGURE 8 CONTINUED)

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

 

 

FLUE

FACTORY-BUILT

 

CHIMNEY

 

 

CHIMNEY LENGTH

 

 

 

NONSOLUBLE

 

 

REFACTORY

 

 

CEMENT

 

 

CHIMNEY LENGTH

 

 

FLUSH WITH INSIDE

 

AIR SPACE

OF FLUE

 

9 IN. MINIMUM

 

 

MASONRY CHIMNEY CONSTRUCTED

TO NFPA 211

AIR SPACE

MINIMUM CLEARANCE 9 IN. ALL AROUND

CHIMNEY CONNECTOR TO HEATER

USE CHIMNEY MFRS. PARTS TO

ATTACH CONNECTOR SECURELY

SOLID INSULATED, LISTED FACTORY-BUILT CHIMNEY LENGTH

SHEET STEEL SUPPORTS

(24 GAUGE MIN. THICKNESS)

PART C FIGURE 8

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

TWO VENTILATED AIR CHANNELS EACH 1 INCH. CONSTRUCTED OF SHEET STEEL.

CHIMNEY THIMBLE

CHIMNEY FLUE

MASONRY CHIMNEY CONSTRUCTED TO NFPA 211

24 GAUGE

VENTILATED THIMBLE WITH TWO 1 INCH AIR CHANNELS

CHIMNEY CONNECTOR

TO HEATER

MINIMUM 6 IN. GLASS

FIBER INSULATION ALL AROUND

SHEET STEEL SUPPORTS (24 GAUGE MIN. THICKNESS)

PART D FIGURE 8

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO

SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

SHEET STEEL SUPPORTS

 

 

MINIMUM CLEARANCE

 

 

2 IN. ALL AROUND

CHIMNEY SECTION

 

 

 

CHIMNEY THIMBLE

1 IN. AIR SPACE TO

 

CHIMNEY LENGTH

 

 

CHIMNEY

 

CHIMNEY CONNECTOR

 

TO HEATER

CONNECTOR

FLUE

 

 

 

 

CHIMNEY

SOLID INSULATED, LISTED

AIR SPACE

FACTORY-BUILT CHIMNEY

2 IN.

LENGTH (12 IN. LONG MIN.)

 

SHEET STEEL SUPPORTS

MASONRY CHIMNEY CONSTRUCTED

(24 GAUGE MIN. THICKNESS)

 

TO NFPA 211

 

PART E - (Figure 8)

In addition to the methods shown by A, B, C, and D of Figure 8, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney.

CONNECTION OF CHIMNEY CONNECTORTO A MASONRY CHIMNEYWHEN CHIMNEY CONNECTOR

DOES NOT PASSTHROUGH A COMBUSTIBLEWALL

If the chimney connector does not have to pass through a combustible wall to get to a masonry chimney, simply connect the chimney connector directly to the masonry chimney's chimney thimble as described and shown by parts C and D of Figure 8. Remember, the chimney connector should extend into the chimney thimble to the innerface of the chimney flue but not beyond; if the chimney connector is extended through the chimney thimble into the chimney flue, resistance to the flow of smoke and gases up the chimney will occur; that flow resistance will have an adverse affect on the operation and performance of the heater and venting system.

8

Image 8
Contents Ussc Materials Tools and Materials NeededTools Safety Rules HEATER/FLOOR Protector Location InstallationMinimum Clearance To Combustible Walls US , Canada Operation of the Heater Chimney ConnectionOn Next On Next Part B Figure Service Hints Chimney MaintenanceModel C226 Repair Parts Baffle and Flue Collar Assembly HOW to Order Repair Parts

C226 specifications

The United States Stove C226 is a striking combination of efficiency, performance, and style, making it an ideal choice for homeowners who seek reliable heating solutions. This wood and coal burning stove is engineered to provide substantial warmth while emphasizing ease of use and durability.

One of the main features of the C226 is its robust construction. Manufactured from heavy-duty cast iron and steel, this stove boasts exceptional durability and heat retention, ensuring that it can withstand even the most intense usage. The C226 is designed to handle a wide variety of wood sizes, accommodating logs up to 18 inches, and it is perfect for both rural and urban settings alike.

The C226 incorporates an ingenious technology known as "air wash" that helps keep the glass door clean for optimal viewing of the flickering flames. This feature reduces the buildup of creosote and soot, enhancing not only the aesthetic appeal but also the safety and efficiency of the stove.

Moreover, the stove's efficient combustion technology is designed to maximize heat output while minimizing emissions. This results in a cleaner burn, which is crucial for maintaining indoor air quality and for adhering to environmental regulations. The C226 also employs an easy-to-use damper that allows for precise control of the air supply, giving users the ability to fine-tune the burn rate according to their heating needs.

The design of the C226 includes a sizable firebox, which contributes to its long burn time. With a heat output rating capable of warming areas of up to 1,500 square feet, it is perfect for medium-sized homes and spaces. The stylish appearance, with its classic black finish and contoured edges, means it fits seamlessly into various interior decors.

Additionally, the C226 features a variety of installation options, compatible with both chimney and venting systems. The versatility of this stove makes it a popular choice among those looking to enhance their home’s heating capabilities while also enjoying the ambiance of a natural fire.

Overall, the United States Stove C226 stands out as a reliable and efficient heating solution. With its solid construction, user-friendly features, and environmentally-friendly performance, it exemplifies what a high-quality wood and coal stove should offer for today’s energy-conscious homeowners.