United States Stove C226 owner manual Operation of the Heater, Chimney Connection

Page 5

Operation of the Heater

1.

BE SURE TO PUT A LAYER OF SAND OR FIREBRICK

 

APPROXIMATELY 1 1/2" THICK IN THE BOTTOM OF THE

 

STOVE BEFORE STARTING FIRE.

2.

Burn wood or wood products only. The wood should be air dried

FLUE CONNECTION-NON-COMBUSTIBLE WALL

NON-COMBUSTIBLE WALL

 

for at least six months prior to use for maximum efficiency.

3.

After the fire has been started and is burning satisfactorily,

 

adjust the rate of burning by opening or closing the draft

 

damper wheel on the feed door.

4.

Never build extremely large fires in this type of heater as

 

damage to the heater or smoking may result.

5.

Provide air into the room for combustion.

ELBOW

BAROMETRIC

THIMBLE COLLAR PIPE

6.

Do Not touch the heater after firing until it has cooled.

7.

Do Not use a grate or elevate fire, build fire directly on hearth.

8.

The fuel feed door must remain closed during operation.

Chimney Connection

MASONRY CHIMNEY

The masonry chimney must comply with UL/ULC codes. Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the heater. See Page 3, Item 5. Look at Fig. 5. The connector pipe and fittings you will need to connect directly to a masonry chimney are shown. If the connector pipe must go through a combustible wall before entering the masonry chimney, consult a qualified mason or chimney dealer. The installation must conform to local fire codes, and NFPA 211(USA) or CAN/CSA- B365-M91(CANADA). Do not connect this heater into the same chimney flue as the fireplace or flue from another heater. The

DRAFT REGULATOR

PIPE

FIG. 5

FLOOR PROTECTOR

CHIMNEY CAP MANDATORY

chimney used for a heater must not be used to ventilate the cellar or basement. If there is a cleanout opening at the base of the chimney, close it tightly.

UL/ULC LISTED CHIMNEY

Carefully follow chimney manufacturer's instructions. Use only listed type HT per UL 103, or ULC S629, 6-in diameter black or blued chimney connector, minimum 24 gauge steel. If your chimney starts at the ceiling (Fig. 7), you will need enough 6" pipe to reach the ceiling.

The top of the chimney must be at least 3 feet above the roof and be at least 2 feet higher than any point of the roof within 10 feet. (Fig 6)

RULES FOR CONNECTOR PIPE INSTALLATION

2 FT. MIN

10 FT.

PIPE REDUCER 11 FT. MINIMUM

BAROMETRIC

DRAFT REGULATOR

PIPE

3 FT. MIN.

NON-COMBUSTIBLE CONSTRUCTIONIN ACCORDANCE WITH NFPA211(USA)orCAN/ CSA-B365-M91

1.

Crimped end of the pipe must be installed toward the heater.

 

The pipe should slide into the flue collar. The pipe should be

 

firmly attached to the flue collar with 3 screws and sealed with

 

furnace cement.

2.

Slope any horizontal pipe upward toward the chimney at least

 

1/4 " inch for each foot of horizontal run.

3.

You must have at least 18" inches clearance between any

 

horizontal piping and the ceiling. (Fig. 2)

4.

The pipe cannot extend into the chimney flue. (Fig. 7)

5.

Seal each connector pipe joint with furnace cement. Also seal

 

the pipe at the chimney.

6.

Use 3 sheet metal screws at each joint to make the piping rigid.

7.

It is recommended that no more than two (2) 90 degree bends

 

be used in the stove pipe installation as more than two (2) may

 

decrease the amount of draw and possibly cause smoke

 

spillage.

NOTE: The chimney connector shall not pass through an attic, roof space, floor, ceiling, or similar concealed space. Where passage through a wall or partition of combustible construction is desired, the installation must conform with CAN/CSA - B365.

FIG. 6

FLOOR PROTECTOR

RIGHT

WRONG

WRONG

FIG. 7

5

Image 5
Contents Ussc Materials Tools and Materials NeededTools Safety Rules HEATER/FLOOR Protector Location InstallationMinimum Clearance To Combustible Walls US , Canada Chimney Connection Operation of the HeaterOn Next On Next Part B Figure Chimney Maintenance Service HintsModel C226 Repair Parts Baffle and Flue Collar Assembly HOW to Order Repair Parts

C226 specifications

The United States Stove C226 is a striking combination of efficiency, performance, and style, making it an ideal choice for homeowners who seek reliable heating solutions. This wood and coal burning stove is engineered to provide substantial warmth while emphasizing ease of use and durability.

One of the main features of the C226 is its robust construction. Manufactured from heavy-duty cast iron and steel, this stove boasts exceptional durability and heat retention, ensuring that it can withstand even the most intense usage. The C226 is designed to handle a wide variety of wood sizes, accommodating logs up to 18 inches, and it is perfect for both rural and urban settings alike.

The C226 incorporates an ingenious technology known as "air wash" that helps keep the glass door clean for optimal viewing of the flickering flames. This feature reduces the buildup of creosote and soot, enhancing not only the aesthetic appeal but also the safety and efficiency of the stove.

Moreover, the stove's efficient combustion technology is designed to maximize heat output while minimizing emissions. This results in a cleaner burn, which is crucial for maintaining indoor air quality and for adhering to environmental regulations. The C226 also employs an easy-to-use damper that allows for precise control of the air supply, giving users the ability to fine-tune the burn rate according to their heating needs.

The design of the C226 includes a sizable firebox, which contributes to its long burn time. With a heat output rating capable of warming areas of up to 1,500 square feet, it is perfect for medium-sized homes and spaces. The stylish appearance, with its classic black finish and contoured edges, means it fits seamlessly into various interior decors.

Additionally, the C226 features a variety of installation options, compatible with both chimney and venting systems. The versatility of this stove makes it a popular choice among those looking to enhance their home’s heating capabilities while also enjoying the ambiance of a natural fire.

Overall, the United States Stove C226 stands out as a reliable and efficient heating solution. With its solid construction, user-friendly features, and environmentally-friendly performance, it exemplifies what a high-quality wood and coal stove should offer for today’s energy-conscious homeowners.