United States Stove VFZC32N, VFZC32L Installation Clearances, Ventilation Air From Outdoors

Page 10

AIR FOR COMBUSTION AND VENTILATION CONTINUED

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. (See Figure 2)

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

Figure 2 - Ventilation Air from Outdoors

INSTALLATION

INSTALLATION CLEARANCES

WARNING

Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling Clearances (see Figure 3)

A.Clearances from the side of the firebox opening to any combustible wall should not

be less than 6 inches. (This applies to built-in installation or using an (optional) cabinet mantel kit.)

B.Clearances from the top of the firebox opening to the ceiling should not be less than 42 inches.

Mantel Clearances for Conventional Installation

10

Image 10
Contents ~WHAT to do if YOU Smell GAS Owners Operation and Installation ManualDo not use a blower insert Heat exchanger insert or other Do not try to light any applianceTable of Contents Local CodesPage VFZC32 Specifications Firebox TOP View Firebox Front View Firebox Side View Locating Fireplace Product FeaturesAIR for Combustion and Ventilation Unusually Tight Construction Providing adequate ventilationConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingMantel Clearances for Conventional Installation InstallationInstallation Clearances Minimum Wall and Ceiling Clearances see FigureMantel Clearances for Built-in Installation Minimum Clearance to Wall and CeilingInstalling the Fireplace Screen Installing the Fireplace HoodInstalling the Firebrick Panels into the firebox GAS Connection Gas ConnectionGAS Pressure Check Flex Pipe Connected to controlMantel Installation Fireplace Installation Using Optional MantelInstalling Firebox on Hearth Base Height Front Width Depth Model # BUILT-IN InstallationBuilt-in Fireplace Installation VFZC32Rough Opening for Installing in Corner Proper Installation Sequence LOG AssemblyLOG Positioning Operating Instructions For Your Safety Read Before LightingFor Your Safety What to do if YOU Smell GASLighting Instructions Turn OFF GAS to ApplianceChecking Flame Appearance Cleaning / ServicingMatch Lighting Instructions Pilot FlameFlame Appearance Periodic CleaningAnnual Cleaning/Inspection FlamesParts Diagram and Parts List KEY Description PART# QTYGenerator Assembly Parts Diagram Generator Assembly Parts List KEY Description QTYVF32B Blower KIT, Wiring Diagram Installing the Optional VF32B Blower KitHearth Base Optional AccessoriesCabinet Mantel Face MantelRemote Control Accessory Blower AccessoryWall Switch Accessory Aluminum Trim KitsHOW to Order Repair Parts Ussc

VFZC32L, VFZC32N specifications

The United States Stove Company has long been recognized for its quality heating solutions, and the VFZC32N and VFZC32L models exemplify this commitment to excellence. These freestanding vent-free zone heaters are designed to provide efficient and effective heating for residential spaces, showcasing advanced technologies and user-friendly features.

The VFZC32N model, with its natural gas configuration, and the VFZC32L, which operates on propane, offer impressive heating capabilities. Both models can effectively heat areas up to 1,200 square feet, making them suitable for various room sizes in homes, garages, or workshops. They feature a clean, modern design that complements contemporary and traditional decor alike, with a sleek finish that enhances any interior space.

One of the standout characteristics of these heaters is their high-efficiency rating. With a 99% thermal efficiency, the VFZC32 series maximizes heat output while minimizing fuel consumption. This efficiency not only leads to lower energy bills but also results in a more eco-friendly heating solution. The vent-free technology allows these units to operate without the need for venting, simplifying the installation process and providing more flexibility in placement.

Safety features are a priority in the VFZC32N and VFZC32L models. Both heaters come equipped with an oxygen depletion sensor (ODS) that automatically shuts off the heater if oxygen levels fall below a safe threshold. Additionally, the built-in thermostat ensures optimal temperature control, allowing for consistent and comfortable heat throughout the space.

User convenience is further enhanced by the electronic ignition system, which provides hassle-free startups without the need for manual lighting. The adjustable flame height allows users to customize the heat output to suit their specific needs, while the easy-access control panel ensures straightforward operation.

In conclusion, the United States Stove VFZC32N and VFZC32L models represent an excellent choice for those seeking reliable and efficient heating solutions. With their impressive efficiency, modern design, and advanced safety features, these vent-free heaters make it easier than ever to enjoy warmth and comfort at home. Whether you are looking to heat a single room or a larger space, the VFZC32 series is certainly worth considering for your heating needs.