United States Stove 6041HF, 6041TP, 6041I Design Guidelines for Outside Combustion AIR Connection

Page 11

DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION

1.For installations with horizontal through-the-wall exhaust, it is strongly recommended that the heater combustion air be connected to the outside. If the home is newer or has been tightly insulated, it is required to install outside combustion air.

2.Connection to outside the house is REQUIRED for mobile home installations. We strongly urge use of the 69FAK Fresh Air Kit.

90 DEGREE BEND TERMINATION

2” Min. Diameter

NOTE:

A wire mesh screen with a maximum

opening size of 3/8” must be

installed in the pipe or elbow for

rodent exclusion.

WIND HOOD TERMINATION

Wind Hood

 

3”

2”

6”

3.Only noncombustible pipe 2 inches (or greater) in diameter is approved to use for outside air connections (straight or flexible). PVC pipe is NOT approved and should NEVER be used.

4.If the air inlet is connected to the outside, it MUST be terminated with a vertical 90-degree bend (down) or with a wind hood. Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simultaneous power failure (see diagram above).

5.Blockage, excessive length, or extra bends in the air intake pipe will starve the heater of combustion air. A 90-degree bend is equivalent in restriction to approximately 30 inches of straight inlet pipe.

CAUTION: The operation of exhaust fans such as bath room fans, attic fans, etc. might starve the heater of combus- tible air creating a negative pressure in the room. Provide adequate ventilation in the room accompanying the heater. If not, the pressure switch may shut off operation of the heater. (Due to negative pressure)

USSC

11

Image 11
Contents Use Hi-Temp silicone at each joint or connection Ussc6041TP/6041HF 6041I SpecificationsHeat Input as tested Heat Output as tested Assembly 6041TP Pedestal Trim Assembly6041HF Assembly Disconnect the Power Cord Before Servicing this Heater 6041I AssemblyComponent Location Burning Solid Fuels Safety StepsContent Installation RequirementsHearth Protection Clearances to Combustibles 6041TPHFClearances to Combustibles Vent Termination Clearances Guidelines for Exhaust Venting Systems DesignDesign Guidelines for Outside Combustion AIR Connection Mobile Home Installation Requirements Installation ConfigurationsDimensional tolerance ±1/4 Minimum of 3 Vertical Feet of Pipe Outside Home is Required Alternative Exhaust Venting Installation AS a BUILT-IN FireplaceInstallation Into a FACTORY-BUILT Metal Fireplace Installation Into a Masonry FireplaceRemoval of Broken or Damaged Ceramic Glass Glass MAINTENANCE, Removal and ReplacementLighting Instructions Understanding the Control BoardTurning the Heater OFF To Start a FireDisposal of Ashes Maintenance InstructionsDaily Maintenance Disposal of AshesFuel Additive Automatic Safety FeaturesWeekly Maintenance Spring CleaningSTART-UP Sequence of Events Control Board FunctionsError Codes and Display Indicators Problem Trouble ShootingWiring Diagram Parts Diagram 6041TP Key Description Qty Parts List 6041TPParts Diagram Key Description Qty Parts ListParts Parts DIAGRAM/LISTUssc Part Number Part Description
Related manuals
Manual 32 pages 490 b