DESIGN GUIDELINES FOR 6041I INSERT INSTALLATION

A MINIMUM OF 3 VERTICAL

FEET OF PIPE OUTSIDE THE

HOME IS REQUIRED!

INSTALLATION AS A BUILT-IN FIREPLACE

A continuous sheet of non-combustible floor protection must be installed underneath the unit to prevent the possibil- ity of embers falling through to the combustible floor. If the floor beneath the unit is of non-combustible material, the protector is not required.

See the “Clearance to Combustibles” section of this manual for installation clearances.

Alternative Exhaust Venting

Depending on your installation, you might consider routing your cleanout tee as illustrated below for ease of cleaning. The access panel in the right side facade allows you to reach the tee from the front side of the unit if venting is assembled as shown. The cleanout tee is attached to a 90° elbow mounted to the unit then rotated at approx. 15-20 degrees. A 12 inch section of “PL” vent is connected to reach the top of the unit to which a flexible pipe may be attached for further termination through a chimney. Clearance to combustibles must be considered if this installation is chosen. A distance of 3 inches must be maintained from the exhaust vent to any combustible material.

USSC

15

Image 15
Contents Use Hi-Temp silicone at each joint or connection Ussc6041TP/6041HF 6041I SpecificationsHeat Input as tested Heat Output as tested 6041TP Pedestal Trim Assembly 6041HF AssemblyAssembly Disconnect the Power Cord Before Servicing this Heater 6041I AssemblyComponent Location Burning Solid Fuels Safety StepsContent Installation RequirementsHearth Protection Clearances to Combustibles 6041TPHFClearances to Combustibles Vent Termination Clearances Guidelines for Exhaust Venting Systems DesignDesign Guidelines for Outside Combustion AIR Connection Mobile Home Installation Requirements Installation ConfigurationsDimensional tolerance ±1/4 Minimum of 3 Vertical Feet of Pipe Outside Home is Required Alternative Exhaust Venting Installation AS a BUILT-IN FireplaceInstallation Into a FACTORY-BUILT Metal Fireplace Installation Into a Masonry FireplaceRemoval of Broken or Damaged Ceramic Glass Glass MAINTENANCE, Removal and ReplacementLighting Instructions Understanding the Control BoardTurning the Heater OFF To Start a FireDisposal of Ashes Maintenance InstructionsDaily Maintenance Disposal of AshesFuel Additive Automatic Safety FeaturesWeekly Maintenance Spring CleaningSTART-UP Sequence of Events Control Board FunctionsError Codes and Display Indicators Problem Trouble ShootingWiring Diagram Parts Diagram 6041TP Key Description Qty Parts List 6041TPParts Diagram Key Description Qty Parts ListParts Parts DIAGRAM/LISTUssc Part Number Part Description
Related manuals
Manual 32 pages 490 b