CLEARANCES TO COMBUSTIBLES
The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE: These are minimum clearances to combustible walls established by the testing lab. The amount of room needed on the left side of the unit to access the electrical panel is (6) six inches (152mm).
PARALLEL - A - | Left Sidewall to Top Edge of Unit | 6 in./152mm |
B - | Sidewall to Flue | 5 in./127mm |
C - | Backwall to Flue | 3 in./75mm |
D - | Backwall to Unit | 9 in./228mm |
E - | Right Sidewall to Top Edge of Unit | 2 in./50mm |
CORNER - F - | Adjacent Wall to Flue | 3 in./75mm |
G - | Adjacent Wall to Unit | 4 in./100mm |
BACK WALL | BACK WALL |
SIDE WALL | SIDE WALL |
Backwall / Sidewall | Corner Installation |
Parallel |
NOTE:
Allow sufficient space to remove the left and right side panels for maintenance purposes.
|
| 6” |
|
| min. |
6” | HEARTH PROTECTION | 6” |
min. |
| min. |
These clearances must be maintained and may only be reduced by means approved by the regulatory authority