INSTALLATION CONFIGURATIONS
Note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA
The American Harvest Corn/Pellet Stove Model 6039/6039T may be installed as follows:
1)A freestanding unit
MOBILE HOME INSTALLATION REQUIREMENTS
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING
REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:
WARNING
DO NOT INSTALL IN SLEEPING ROOM
1)Stove must be permanently bolted to the floor. Remove the Base Trim and bolt thru the base flange.
2)Stove must have permanent outside air source. (67FAK)
3)Stove must be permanently electrically grounded to the steel chassis of the mobile home.
4)All vertical chimney vent must have wall supports.
5)All exhaust systems must have a spark arrestor.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
ROOF MUST BE MAINTAINED.
Check with your local building official as other codes may apply.
FREESTANDING STOVE INSTALLATION REQUIREMENTS
General Horizontal Exhaust Termination (Follow manufacturer’s instructions):
1)Locate proper position for the type “PL” wall thimble (F).
2)Use a saber saw or keyhole saw to cut a 7
3)Position stove approximately 12” from the wall on the noncombustible floor pad. Push the type “PL” pipe (B) through the wall thimble (D). Squeeze a bead of high temperature RTV silicone sealer (A) around the outside of the 3” diameter exhaust pipe approximately ½” from the stove back panel. Firmly push on a section of type “PL” pipe (B) until the inner pipe liner pushes up against the bead of RTV sealer. Don’t seal the entire 3” diameter pipe as you will not be able to disassemble the pipe at a later date. The bead of silicone will act as a gasket right on the end of the 3” pipe (B). Alternate Method: An approved type “PL” connector back clamp may be used to allow easy disconnect for mainte- nance. (The RTV sealant must be used in mobile home installation)
4)Push stove with pipe attached towards wall. Pipe (B) will go through the wall thimble (F). Be careful not to dislodge the thimble. Position stove not closer than 9” to the wall.
5)Install type “PL” termination cap (G) with rodent screen cap (optional) on outside end or pipe. Note: The end of the exhaust pipe must extend a minimum of 12 inches from the outside of the building. Rodent screen cannot be less than 3/8” opening mesh.
6)If installing with combustion air from outside, cut a separate hole through the wall for the fresh air tube (C). This tube must be 2” minimum diameter pipe. Connect outside air pipe inlet on stove. This tube must be terminated with a 90 degree elbow or hood.
USSC | 9 |