United States Stove 5500/5500XL Interior Chambers, ASH Disposal, Check and Clean the Hopper

Page 15

Maintenance

INTERIOR CHAMBERS

Periodically remove and clean the burnpot and the area inside the burnpot housing. In particular it is advisable to clean out the holes in the burnpot to remove any build up that may prevent air from moving through the burn pot freely.

If a vacuum is used to clean your stove, we suggest using a vacuum designed for ash removal. Some regular vacuum cleaner (i.e. shop vacs) may leak ash into the room.

ASH DISPOSAL

Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.

CHECK AND CLEAN THE HOPPER

Check the hopper periodically to determine if there is any sawdust or pellets that are sticking to the hopper surface. Clean as needed.

MAIN DOOR GASKETS

Inspect the main door and glass window gaskets periodically. The main door may need to be removed to have frayed, broken, or compacted gaskets replaced by your Authorized “King/Ashley” Dealer.

FAN MOTORS

Clean the air holes on the motors of both the exhaust and room air fans annually. Remove the exhaust blower from the exhaust duct and clean out the internal fan blades as part of your fall start-up.

PAINTED SURFACES

Painted surfaces may be wiped down with a damp cloth. If scratches appear, or you wish to renew your paint, contact your Authorized “King/AshleyDealer to obtain a can of suitable high-temperature paint.

GLASS

We recommend using a high quality glass cleaner. Should a build up of creosote or carbon accumulate, you may wish to use 000 steel wool and water to clean the glass. In the event you need to replace the glass, only high temperature ceramic glass of the correct size and thickness may be used. Contact your Authorized “King/AshleyDealer to obtain this glass.

FALL START UP

Prior to starting the first fire of the heating season, check the outside area around the exhaust and air intake systems for obstructions. Clean and remove any fly ash from the exhaust venting system. Clean any screens on the exhaust system and on the outside air intake pipe. Turn all of the controls on and make sure that they are working properly. This is also a good time to give the entire stove a good cleaning throughout.

SPRING SHUTDOWN

After the last burn in the spring, remove any remaining pellets from the hopper and the auger feed system. Scoop out the pellets and then run the auger until the hopper is empty and pellets stop flowing (this can be done by pressing the “ON” button with the viewing door open). Vacuum out the hopper. Thoroughly clean the burnpot, and firebox. It may be desirable to spray the inside of the cleaned hopper with an aerosol silicone spray if your stove is in a high humidity area. The exhaust system should be thoroughly cleaned.

YEARLY SERVICING

A yearly servicing and cleaning by your Authorized “King/Ashley” Dealer is recommended. A fee may be charged for this service.

USSC

PelletKing.com

15

 

Image 15
Contents King/Ashley Pellet Stove Table of Contents Safety Precautions Specifications Safety and EPA ComplianceFuel Considerations Installation Installation OptionsFloor Protection Clearances Pellet Vent Type Pellet Vent InstallationVenting Requirements Maximum Venting DistanceVent Termination Clearances Through the ROOF/CEILING Installation Through the Wall Installation Recommended InstallationSpecial Mobile Home Requirements Outside AIR Supply optionalHOW Your Stove Works OperationControl Panel Unit PreparationPerforming a DRY RUN Shut Down Procedure START-UP ProcedureExhaust System MaintenanceSafety and Convenience Features Daily OperationMain Door Gaskets Check and Clean the HopperInterior Chambers ASH DisposalProblem Trouble ShootingParts Diagram model 5500 and 5500XL Title Qty Parts Diagram/List models 5500 & 5500XLParts List model 5500 & 5500XL PelletKing.com