United States Stove 5500/5500XL Specifications, Fuel Considerations, Safety and EPA Compliance

Page 4

Specifications

Heating Specifications

Heat Output1

48,000 BTU/hr.

 

Heating Capacity2

800 - 2,000 sq. ft.

Fuel Burn Rate3

2.0 - 6.0 lbs./hr.

 

Burn Time (lowest setting)

5500

- 60 hrs.

5500XL - 160 hrs.

Hopper Capacity

5500

- 150 lbs.

5500XL - 320 lbs.

1BTU output will vary depending on the quality of fuel. Use PFI listed fuels for the best results.

2Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature.

3Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.

Dimensions

 

5500

5500XL

Height

34 in.

47 1/4 in.

 

 

 

Width

26 in.

26 hrs.

Depth

25 in.

25 hrs.

 

 

 

Weight

250 lbs.

275 hrs.

Electrical Specifications

Electrical Rating

110-120 volts, 60 HZ, 3.0 Amps

 

 

Watts (operational)

175 (approx.)

 

 

Watts (igniter running)

425 (approx.)

 

 

FUEL CONSIDERATIONS

Your King/Ashley stove is designed to burn premium hardwood pellets that comply with Association of Pellet Fuel Industries standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no greater than 1.5”, not less than 8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). Pellets that are soft, contain excessive amounts of loose sawdust, have been, or are wet, will result in reduced performance.

SAFETY AND EPA COMPLIANCE

Your King/Ashley stove has been safety tested and listed to ASTM E 1509, (UM) 84-HUD by OMNI-Test Laboratories, Inc. Beaverton, Oregon, USA. It is also exempt from EPA Phase II requirements.

4

PelletKing.com

USSC

 

Image 4
Contents King/Ashley Pellet Stove Table of Contents Safety Precautions Safety and EPA Compliance SpecificationsFuel Considerations Installation Options InstallationFloor Protection Clearances Pellet Vent Installation Venting RequirementsMaximum Venting Distance Pellet Vent TypeVent Termination Clearances Through the Wall Installation Recommended Installation Through the ROOF/CEILING InstallationOutside AIR Supply optional Special Mobile Home RequirementsOperation HOW Your Stove WorksUnit Preparation Control PanelPerforming a DRY RUN START-UP Procedure Shut Down ProcedureMaintenance Safety and Convenience FeaturesDaily Operation Exhaust SystemCheck and Clean the Hopper Interior ChambersASH Disposal Main Door GasketsTrouble Shooting ProblemParts Diagram model 5500 and 5500XL Parts Diagram/List models 5500 & 5500XL Title QtyParts List model 5500 & 5500XL PelletKing.com