Specifications

Heating Specifications

Input Rating

38,500

BTU/hr

Heat Output1

30,000

BTU/hr.

Efficiency

78%

 

Heating Capacity2

850 sq. ft.

Fuel Burn Rate3

3.5 lbs./hr. ±5%

Burn Time (lowest setting)

11-1/2 hrs. ±5%

Hopper Capacity

40 lbs.

 

 

 

 

1BTU output will vary depending on the quality of fuel. Use PFI listed fuels for the best results.

2Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature.

3Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.

Dimensions

Height

Width

Depth

33-1/2 in.

18-1/4 in.

19-1/4 in.

Electrical Specifications

Electrical Rating

110-120 volts, 60 HZ, 4.5 Amps

 

 

Watts (maximum)

520 (approx.)

 

 

FUEL CONSIDERATIONS

Your Pellet stove is designed to burn premium hardwood pellets that comply with Association of Pellet Fuel Industries standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no greater than 1.5”, not less than 8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). Pellets that are soft, that contain excessive amounts of loose sawdust, or that have been or are wet will result in reduced performance. Due to the different fuel densities and sizes, the fuel feed rate may vary. This may require an adjustment to the slider damper setting or the auger feed trim setting on low.

SAFETY AND EPA COMPLIANCE

Your Pellet stove has been safety tested and listed to ASTM E 1509, by OMNI-Test Laboratories, Inc. Portland, Oregon, USA. It is also certified and tested to EPA Phase II requirements.

4

USSC

Image 4
Contents Ussc Table of Contents Safety Precautions Safety and EPA Compliance SpecificationsFuel Considerations Installation Options InstallationFloor Protection Clearances AlcovePellet Vent Installation Venting RequirementsMaximum Venting Distance Pellet Vent TypeVent Termination Clearances Through the Wall Installation Recommended Installation Through the ROOF/CEILING InstallationSpecial Mobile Home Requirements Understanding your stove How your stove worksShut Down Procedure START-UP ProcedureOperation Maintenance Safety and Convenience FeaturesDaily Operation Exhaust SystemCheck and Clean the Hopper Interior ChambersASH Disposal Door and Glass GasketsTrouble Shooting ProblemParts Diagram Parts List Wiring Diagram Ussc Ussc