Lenox XC14, Elite Series installation instructions VAC Control Wiring Diagrams Field Installed

Page 20

XC13

XC13

XC13

XC13

XC13

XC13

XC13

NOTE − Refer to furnace, blower coil and accessory instructions for additional wiring configurations with other optional controls.

Figure 14. 24VAC Control Wiring Diagrams (Field Installed)

DUAL RUN CAPACITOR

 

 

(C12)

 

FAN MOTOR (B4)

 

 

CONTACTOR

 

 

K1

 

 

 

 

THERMAL PROTECTION

 

 

SWITCH (S5)

 

 

HIGH PRESSURE

 

 

SWITCH (S4)

GROUND LUG

 

 

−048 AND −060

 

COMPRESSOR

 

(B1)

ONLY

 

 

 

 

CRANKCASE

CRANKCASE

 

THERMOSTAT

 

HEATER (HR1)

 

(S40)

 

 

Figure 15. Typical Factory Wiring Diagram (Copeland Compressor)

Page 20

506636−01

Image 20
Contents Table of Contents GeneralShipping and Packing List AIR Conditioner230 Unit Dimensions − Inches mmModel Number Identification Control Panel Plumbing and Switches ComponentsTypical Unit Parts Arrangement Operating Gauge Set and Service Valves Using Manifold Gauge SETOperating Service Valves Torque RequirementsOperating Angle Type Service Valve Operating Ball Type Service ValveTo Access Service Port Reinstall Stem CapRecovering Refrigerant from Existing System 1DISCONNECT PowerRecovering Refrigerant 2CONNECT Manifold Gauge SETUnit Placement Clearance on ALL SidesPositioning Considerations Placing Unit on SlabDetail a Outside Unit Placement Detail C Elevated Slab Mounting using Feet ExtendersDetail D Slab Side Mounting Detail E Deck Top MountingRemoving and Installing Panels Louvered Panel InstallationRoof Mounting Louvered Panel RemovalRefrigerant Line Set New or Replacement Line SetRefrigerant Line SET Refrigerant Line SET From Vertical to Horizontal Refrigerant Line SET Alling Horizontal RunsBrazing Connections Brazing Procedures 1CUT and DeburWrap Service Valves Flow Nitrogen6BRAZE Line SET 7PREPARATION for Next StepInstalling Indoor Expansion Valve Flushing Line Set and Indoor CoilInstalling Indoor Metering Device Indoor Expansion Valve InstallationSensing Bulb Installation Equalizer Line InstallationLeak Test Line Set and Indoor Coil Leak TestEvacuating Line Set and Indoor Coil Evacuating SystemSize Circuit and Install Disconnect 2INSTALL ThermostatElectrical 24VAC TransformerVAC Control Wiring Diagrams Field Installed Typical Factory Wiring Diagram Interlink Compressor Typical Unit Wiring Diagram Connections for Testing and Charging Servicing Units Delivered Void of ChargeUnit Start−Up System RefrigerantDetermining Charge Method Which indoorMetering Device?Checking AIR Flow AT Indoor Coil Calculating System Charge for Outdoor Unit Void of ChargeAbove Below40ºF SHº Superheat Values +/−5ºFUnit Components System OperationNormal Operating Pressures Liquid +10 and Suction +5 psig Maintenance Indoor UnitIndoor Coil Unit Nameplate ActualStart−Up and Performance Checklist Installer CityJob Name Job no Date Job Location City State

Elite Series, XC14 specifications

The Lenox Elite Series XC14 is a remarkable tool designed for superior cutting performance in various applications. This saw blade stands out due to its innovative technologies and features, which cater to the needs of professionals in woodworking, metalworking, and general cutting tasks.

One of the key features of the XC14 is its carbide-tipped teeth. These teeth are engineered for longevity and efficiency, allowing for extended use without performance degradation. The unique geometry of the teeth enhances cutting speed while minimizing resistance, making it ideal for a range of materials including hardwoods, softwoods, and metals.

The blade’s construction is another significant aspect of its design. Made from high-quality steel, the XC14 ensures durability and resistance to bending or warping under stress. This robust construction contributes to the blade's overall stability, resulting in smoother cuts and reduced vibration during operation.

Another noteworthy technology embedded in the XC14 is its advanced tooth design. The combination of alternate top bevel (ATB) and flat (F) configurations allows for precision cutting and a cleaner finish. This feature is particularly beneficial when working on intricate projects that require a high level of accuracy.

To enhance performance further, the XC14 incorporates a unique thin kerf design. This design reduces the width of the cut, which not only conserves material but also requires less power from the saw. This energy efficiency translates to less wear on the saw, extending the lifecycle of both the blade and the tool itself.

The blade is also designed with heat dissipation in mind. Specially engineered cooling vents help in maintaining optimal temperature during operation. This technology reduces the risk of overheating, which can compromise the integrity of the blade and the quality of the cut.

Versatility is another standout feature of the Lenox Elite Series XC14. It is suitable for table saws, miter saws, and portable saws, making it a valuable tool for professionals and DIY enthusiasts alike. Whether tackling large construction projects, meticulous cabinetry, or small home repairs, the XC14 adapts efficiently to diverse cutting needs.

In conclusion, the Lenox Elite Series XC14 combines advanced technologies, premium materials, and thoughtful design to deliver exceptional cutting performance. Its carbide-tipped teeth, innovative geometry, stable construction, thin kerf, heat dissipation features, and versatility make it a top choice for those seeking reliable and efficient cutting solutions in various applications.