BENDIX SD-08-2433 manual Purge Cycle Refer to Figures 3

Page 5

DESICCANT

BED

COMPRESSOROIL

COALESCING

FILTER

 

 

 

CONTROL

 

PURGE

 

 

 

LINE

 

ORIFICE

 

 

 

 

 

PURGE AIR

CONTROL

 

 

EXTENDED

 

 

PURGE

PORT

 

 

PORT

TURBO

 

 

REAR

CUT-OFF

 

 

 

 

RESERVOIR

VALVE

 

 

DELIVERY

(CLOSED)

 

 

CHECK

 

 

 

 

 

VALVE

SUPPLY

 

 

 

PORT

 

 

 

 

SAFETY

 

 

FRONT

 

VALVE

EXHAUST

 

RESERVOIR

 

 

 

PURGE

 

 

 

 

 

VALVE

 

DELIVERY

 

 

 

 

GOVERNOR

 

 

 

EXHAUST

PORT

 

 

 

 

 

FIGURE 3 - BENDIX® AD-9siAIR DRYER WITH GOVERNOR—PURGE CYCLE

PURGE CYCLE (Refer to Figures 3 and 5)

When air brake system pressure reaches the cut-out setting of the governor, the integral governor unloads the compressor by supplying a pressure signal through the control port (CON 2-4). This signal activates the purge cycle of the air dryer.

The governor unloads the compressor by allowing air pressure to fill the line leading to the compressor unloader mechanism. This suspends the delivery of compressed air to the Bendix® AD-9siair dryer.

Similarly, the governor also supplies this air pressure signal to the purge valve. The pressure moves the air dryer purge piston down, opening the purge valve to atmosphere and closing off the compressor air supply to the turbo cut-off

valve (described in the "Turbo Cut-off Feature" section of this document). Water and contaminants captured are expelled immediately when the purge valve opens. In addition, air — which was flowing through the desiccant cartridge — changes direction and begins to flow from the purge volume toward the open purge valve. Contaminants collected by the air dryer filters and desiccant are removed by air flowing from the purge volume through the desiccant drying bed to the open purge valve.

The initial purge and desiccant cartridge decompression lasts only a few seconds, evidenced by an audible burst of air at the air dryer exhaust.

5

Image 5
Contents SD-08-2433 General Safety Guidelines Description Charge Cycle Refer to Figures 2 Purge Cycle Refer to Figures 3 Bendix AD-9siAIR Dryer Without GOVERNOR-CHARGE Cycle Turbo CUT-OFF Feature Refer to Figures Preventive Maintenance General Temporary AIR Dryer Bypass Bendix AD-9siAIR Dryer Serviceable Components Delivery Check Valve Cleaning Procedure Troubleshooting Chart Refer to the Bendix Air Dryer Application Guideline BW2600 Troubleshooting Guide for Air Brake Compressor BW1971 Log-on and Learn from the Best