BENDIX SD-08-2433 manual Preventive Maintenance

Page 8

PREVENTIVE MAINTENANCE

Important: Review the warranty policy before performing any intrusive maintenance procedures. An extended warranty may be voided if intrusive maintenance is performed during this period. Purge valve and governor maintenance is permissible during the warranty period only when using a genuine Bendix® AD-9sipurge valve governor kit.

Because no two vehicles operate under identical conditions, maintenance and maintenance intervals will vary. Experience is a valuable guide in determining the best maintenance interval for any one particular operation.

Every 900 operating hours, or 25,000 miles, or three

(3) months:

1.Check for moisture in the air brake system by opening reservoir drain valves and checking for the presence of water. If moisture is present, the desiccant cartridge may require replacement; however, the following conditions can also cause water accumulation and should be considered before replacing the desiccant:

A.An outside air source has been used to charge the system. This air did not pass through the drying bed of the air dryer.

B.Air usage is exceptionally high and not normal for a highway vehicle.

This may be due to accessory air demands or some unusual air requirement that does not allow the compressor to load and unload (compressing and non-compressing cycle) in a normal fashion. Check for high air system leakage. If the vehicle vocation has changed, it may be necessary to upgrade the compressor size. Contact the Bendix TechTeam at1-800-AIR-BRAKE (1-800-247-2725), option 2, or www.bendix.com for more information.

C.The location of the air dryer is too close to the air compressor. See the troubleshooting chart at the end of this document (Symptom 2 - Remedy A).

D.In areas where more than a 30° range of temperature occurs in one day, small amounts of water can temporarily accumulate in the air brake system due to condensation. Under these conditions, the presence of small amounts of moisture is normal.

HEATER & THERMOSTAT

CONNECTOR

FIGURE 6 - HEATER AND THERMOSTAT CONNECTOR

For Bendix AD-9si air dryers: Preventive Maintenance is as easy as 1-2-3

Adhering to a preventive maintenance schedule is crucial to keeping a vehicle’s air system clean and ensuring superior performance of all components that utilize system air— such as brakes, emissions equipment and automated manual transmissions. Depending on vocation, Bendix recommends a 1-, 2- or 3-year air dryer cartridge replacement on vehicles equipped with a Bendix® compressor.

For severe service application — such as residential refuse trucks or school buses — the air dryer cartridge should be replaced every year or 100,000 miles; for pick- up and delivery operations, or for double- and triple-trailer line haul trucks, every two years or 200,000 miles is the recommendation. Line-haul operations using a single trailer should swap the filter out every three (3) years or 300,000 miles. The recommended intervals for trucks equipped with non-Bendix compressors are six months (50,000 miles), one year (100,000 miles), and two years (200,000 miles), respectively.

More frequent intervals may be required depending on a vehicle’s age, its compressor condition, use of a non-Bendix compressor, the operating environment, the vehicle’s vocation, and its usage. In conjunction with these guidelines, fleets can determine the functionality of their filters by checking for moisture in the air brake system monthly. If moisture is present, the air dryer cartridge may require replacement. Reference the Bendix Service Data Sheet of the specific air dryer for additional information. (Recommended intervals for trucks equipped with non- Bendix compressors are six months (50,000 miles), one year (100,000 miles), and two years (200,000 miles), respectively.)

8

Image 8
Contents SD-08-2433 General Safety Guidelines Description Charge Cycle Refer to Figures 2 Purge Cycle Refer to Figures 3 Bendix AD-9siAIR Dryer Without GOVERNOR-CHARGE Cycle Turbo CUT-OFF Feature Refer to Figures Preventive Maintenance General Temporary AIR Dryer Bypass Bendix AD-9siAIR Dryer Serviceable Components Delivery Check Valve Cleaning Procedure Troubleshooting Chart Refer to the Bendix Air Dryer Application Guideline BW2600 Troubleshooting Guide for Air Brake Compressor BW1971 Log-on and Learn from the Best