BENDIX®AD-9siAIR DRYER

TROUBLESHOOTING CHART

SYMPTOM

 

CAUSE

 

REMEDY

2. Water in vehicle reservoirs.

A.

Maximum air dryer inlet temperature is

A.

Check for excessive carbon build-up in compressor discharge

 

 

exceeded due to improper discharge

 

line. Replace if required. Make certain that discharge line

 

 

line length.

 

length is at least 6 ft. Increase discharge line length and/or

 

 

 

 

diameter to reduce air dryer inlet temperature.

 

B.

Ambient temperature exceeds 125°F.

B.

Relocate the air dryer away from excessive heat source.

 

C.

Air system charged from outside

C.

If system must have outside air fill provision, outside air should

 

 

air source (outside air not passing

 

pass through the air dryer.

 

 

through air dryer).

 

 

 

D.

Excessive air usage - Air dryer not

D.

Refer to the Bendix® Air Dryer Application Guideline (BW2600)

 

 

compatible with vehicle air system

 

for proper application of the Bendix® AD-9siair dryer. An

 

 

requirement (improper air dryer/

 

extended purge reservoir may be added for higher air usage

 

 

vehicle application).

 

vehicles, such as city buses and construction vehicles.

 

 

 

If the vehicle is equipped with high air usage accessories

 

 

 

 

 

 

 

 

such as trailer pump-off systems or central tire inflation, the

 

 

 

 

air for these accessories must by-pass the air dryer.

 

E.

Desiccant requires replacement.

E.

Replace desiccant cartridge assembly. See Bendix Air Dryer

 

 

 

 

Application Guideline (BW2600) for recommended service

 

 

 

 

intervals.

 

F.

Air dryer not purging.

F.

Refer to Symptom 6.

 

G.

Purge (air exhaust) time insufficient

G.

Refer to Symptom 1.

 

 

due to excessive system leakage.

 

 

3. Safety valve on air dryer

A.

Safety valve setting too low (<150 psi).

A.

Replace safety valve.

“popping off” or exhausting

B.

System pressure too high (>135 psi).

B.

Test with accurate gauge. Replace the governor cartridge if

air.

 

 

 

necessary.

 

C.

Excessive pressure pulsations from

C.

Increase the volume in the discharge line. This can be

 

 

compressor. (Typical single cylinder

 

accomplished by adding a 90 cubic inch (or larger) reservoir

 

 

type).

 

between the compressor and the AD-9si air dryer.

4. Constant exhaust of air at air

A.

Air dryer purge valve leaking

A.

With compressor loaded, apply soap solution on purge valve

dryer purge valve exhaust

 

excessively.

 

exhaust, to test for excessive leakage. Repair or replace

or unable to build system

 

 

 

purge valve as necessary.

pressure. (Charge mode.)

B.

Purge valve frozen open - faulty heater

B.

Refer to paragraph 5 of the Operation and Leakage Tests for

 

 

and thermostat, wiring, blown fuse.

 

heater and thermostat test.

 

C.

Defective AD-9siair dryer delivery

C.

Refer to Symptom 1, Remedy B.

 

 

check valve.

 

 

 

D.

Leaking turbo cut-off valve.

D.

Repair or replace purge valve assembly.

 

E.

Defective governor.

E.

Check the governor at both “cut-in” and “cut-out” positions

 

 

 

 

for proper pressures and excessive leakage at the exhaust.

 

F.

Leaking purge valve control piston

F.

Repair or replace purge valve assembly.

 

 

seals.

 

 

14

Image 14
Contents SD-08-2433 General Safety Guidelines Description Charge Cycle Refer to Figures 2 Purge Cycle Refer to Figures 3 Bendix AD-9siAIR Dryer Without GOVERNOR-CHARGE Cycle Turbo CUT-OFF Feature Refer to Figures Preventive Maintenance General Temporary AIR Dryer Bypass Bendix AD-9siAIR Dryer Serviceable Components Delivery Check Valve Cleaning Procedure Troubleshooting Chart Refer to the Bendix Air Dryer Application Guideline BW2600 Troubleshooting Guide for Air Brake Compressor BW1971 Log-on and Learn from the Best