4.Do not locate the PuraGuard QC™ filter near heat producing components such as the vehicle exhaust and provide adequate clearance from moving components e.g. drive shaft, suspension, pitman arm, etc.
5. Locate the PuraGuard QC™ filter on the vehicle so that a minimum of 12 inches of clearance is available horizontally (90° minimum arc) to allow servicing. This will permit a strap wrench to be used when replacing the filter.
6.Be sure that there is sufficient room to attach hoses to the PuraGuard QC™ filter.
7.To permit draining of collected contaminants, at least a 6 inch clearance below the filter is recommended. Nominal clearance above is required.
8.The PuraGuard QC™ oil coalescing filter must be installed after a properly functioning air dryer. Failure to locate the filter after an air dryer can cause the filter to malfunction. An air dryer eliminates certain conditions in the discharge line that could compromise the design of the filter.
9.Do not mount the unit in the engine compartment.
MOUNTING THE PURAGUARD QC™ OIL COALESCING FILTER
1.After positioning the PuraGuard QC™ oil coalescing filter according to the installation requirements, mark the position of the mounting holes on the frame rail. Note: Check the vehicle manual before drilling a frame member.
2.Use vehicle manufacturer guidelines for mounting hardware (use at least grade 5 hardware). Torque to
CONNECTING THE AIR HOSES
1.The PuraGuard QC™ filter supply and delivery ports are
2.Hoses must be installed without tight turns that might cause air flow restrictions. Note: Check that the hose attachment agrees with the air flow arrow symbol (see Figure 1).
OPERATIONAL TEST
Build the air system to governor cutout. Shut off the engine. Using a soap solution, check all hoses and fittings leading
to and from the filter for leakage and integrity. Repair any excessive leaks - exceeding a 1 inch bubble in 5 seconds - before restoring vehicle to service.
MAINTENANCE KIT INSTALLATION
KIT DESCRIPTION
A kit is available for cartridge replacement.
VEHICLE PREPARATION
1.Park the vehicle on a level surface and prevent movement by means other than the brakes.
2.Drain all reservoirs to 0 p.s.i.
3.Drain the contents of the sump into a suitable container for disposal and then close the drain valve.
DISASSEMBLY AND CLEANING
1.Using a strap wrench, unscrew the cartridge.
2.Remove and discard the cartridge.
INSPECTION
1.Inspect the PuraGuard QC™ oil coalescing filter for broken or missing parts. Replace as necessary.
2.Inspect the drain valve for any
3.Inspect the housing during filter replacement. Replace the PuraGuard QC™ oil coalescing filter if the body is becoming clogged with carbon or dirt, clean the supply and delivery ports if necessary.
ASSEMBLY
1.Tighten the replacement cartridge by turning the cartridge 180° after the cartridge seal touches the aluminum body. Tighten with a strap wrench, do not tighten by turning the drain valve.
OPERATIONAL TEST
Build the air system to governor cutout. Shut off the engine. Using a soap solution, check all hoses and fittings leading to and from the PuraGuard QC™ filter for leakage and integrity. Repair any excessive leaks - exceeding a 1 inch bubble in 5 seconds - before restoring vehicle to service.
4