User’s Information Manual
3EnergyRite control module
Access modes
Modes of operation
There are three modes of operation: 1) Off, 2) Pool, and 3) Spa. The factory default mode is Off.
Setup menu
Additional features can be accessed and adjusted through the Setup Menu. Please reference the EnergyRite Service Manual for a detailed description of the Setup Menu.
Off mode
When in Off Mode the control will display CONTROL OFF and will not monitor any of the inputs.
Service menu
Temperature rise and data logging information can be accessed from the Service Menu. Please reference the EnergyRite Service Manual for a detailed description of the Service Menu.
| Status Display Screens | |
|
| |
Display shows: | Description | |
|
| |
Control: OFF | The control module has been placed in the Off Mode. | |
|
| |
Pool: Standby | The unit has not received a call for heat. | |
|
| |
Pool Temp = ***°F | Indicates the current inlet water temperature. | |
|
| |
| A call for heat has been initiated. The blower has been powered and | |
Pool Mode Prepurge | the air pressure switch has closed. The prepurge period is 15 | |
| seconds. | |
|
| |
Pool Mode Ignition | After the prepurge period, the unit has begun an 8 second spark | |
period to light the main burners. | ||
| ||
|
| |
Pool: Heating | The burners have fired and the flame has been detected. | |
|
| |
Standby | Remote is active and has either satisfied the set point or there is no | |
call for heat from the remote. | ||
| ||
|
|
10