Lochinvar SSB-i & s--01 Thermostat, Chattering Contactors or Noisy Relay Cause a, Removal

Page 5

CAUSE B

Control thermostat may be set too high or be defective.

SOLUTION - Reset thermostat(s). If condition is not corrected, replace thermostat(s).

CHATTERING CONTACTOR(S) OR NOISY RELAY.

CAUSE A

Contactors chatter or hum excessively when pulled in.

SOLUTION - Accumulation of dirt will prevent proper seating of armature. Remove contactor and clean. If proper seating is prevented by warpage of the frame or distorted coil, contactor should be replaced. Check for loose connections or wire connections with insulation under crimp.

CAUSE B

Contactors chatter only at pull-in or drop-out, or low water cutoff relay is noisy.

SOLUTION - Check for low voltage at control circuit and at secondary side of transformer. If voltage is below 120 volts, replace transformer. Low water cutoff probe may be fouled. To check, remove wire from LWCO probe and ground to tank. If LWCO board relay pulls in and stops chattering, the probe is fouled. To clean, drain water from tank, remove probe and clean probe tip.

THERMOSTAT

ADJUSTMENT AND RECALIBRATION

The thermostats are factory calibrated to produce 185-190ºF

(85-88ºC) temperatures. If recalibration is necessary, turn screw (G) counterclockwise to lower the set point or turn the adjustment nut (F) counterclockwise to raise the set point (must hold screw (G) at high stop). NOTE: one-sixth of a turn equals 12ºF (6.7ºC).

These thermostats are checked and accurately set at out factory. If recalibration is necessary, a 1/4 turn clockwise to screw (F) will decrease the temperature 12ºF (6.7ºC).

REMOVAL

1.Shut off power and drain tank; remove leads from terminals (E).

2.Loosen nut (A), then remove bushing (B) from tank. Thermostat with bracket and sensor bulb (C) can now be removed from tank.

INSTALLATION

1.Pull end of sensor bulb (C) into recess in bushing (B).

2.Insert bushing (B) and sensor bulb into tank; holding sensor bulb in place with capillary tube, tighten bushing (B).

3.Lock sensor bulb and capillary tube in place by tightening nut (A).

CAUTION !!

Do not overtighten nut, or sleeve inside of bushing will cut through tubing.

4.Replace thermostat on bracket. Replace leads on thermostat terminals.

CAUTION !!

Be sure tank is filled with water before turning on power.

5

Image 5
Contents Electrical Connections Electrical Installation Plumbing InstallationTemperature and Pressure Relief Valve Plumbing Connections TEMPERATURE/PRESSURE GaugesPressure Reducing Valve InletBooster Heater Service Procedures Installation CheckCause G Cause FInstallation Adjustment and RecalibrationThermostat Chattering Contactors or Noisy Relay Cause aRecalibration High Temperature Limit SwitchBreaker or Fuse Size Circuit Breaker and Fused Disconnect Switch SizesDimensions Hanging Support Plumbing Connections Page

SSB-i & s--01 specifications

Lochinvar has established itself as a leader in the field of high-efficiency heating solutions, and its SSB-i and S--01 models exemplify the brand’s commitment to innovation and performance. These systems are designed for both residential and commercial applications, providing versatile solutions to meet a range of heating demands.

The Lochinvar SSB-i series features a robust stainless steel heat exchanger, ensuring durability and longevity. This series is engineered to achieve outstanding thermal efficiency, often exceeding 95%, which significantly reduces energy consumption and operational costs. The advanced technology utilized in the SSB-i includes modulating burners that automatically adjust to the heating demands, providing consistent comfort while minimizing fossil fuel usage.

On the other hand, the S--01 model stands out with its space-saving design, making it ideal for installations where room is limited. The S--01 maintains high efficiency through its innovative design that promotes optimal air and fuel mixing, which leads to cleaner combustion and reduced emissions. It is also equipped with an advanced control system that allows for precise monitoring and adjustments, ensuring that the heating system operates at its best regardless of external conditions.

Both models come equipped with user-friendly digital interfaces, allowing homeowners and facility managers to easily program and control settings. This integration of smart technology means users can manage their heating systems remotely, enhancing energy efficiency and convenience. Additionally, Lochinvar has incorporated advanced safety features such as flame safeguards and high limit controls in both models, offering peace of mind and operational reliability.

The SSB-i and S--01 units are also compatible with various renewable energy sources, such as solar thermal systems, making them an environmentally friendly choice. Their compact size and flexibility in installation options mean they can seamlessly fit into a variety of spaces, whether retrofitting an existing system or as part of a new construction project.

In summary, the Lochinvar SSB-i and S--01 models showcase the company’s dedication to efficient, sustainable, and reliable heating solutions. With their advanced technologies, user-friendly features, and focus on safety and efficiency, these systems are an excellent investment for those looking to improve their heating capabilities while minimizing their environmental footprint.