Teka EX/70 5G AI AL TR FUND, EX/60 4G AI FUND manual Conversions, Replacing the Injectors

Page 10

CONVERSIONS

10) REPLACING THE INJECTORS

The burners can be adapted to different types of gas by mounting injectors suited to the type of gas in question. To do this, first remove the burner tops using a wrench "B". Now unscrew injector "A" (see fig. 13) and fit a injector corresponding to the utilized type of gas in its place.

It is advisable to strongly tighten the injector in place.

After the injectors have been replaced, the burners must be regulated as explained in paragraphs 9.

The technician must reset any seals on the regulating or pre-regulating devices. The envelope with the injectors and the labels can be included in the kit, or at disposal to the authorized customer Service Centre.

For the sake of convenience, the nominal rate table also lists the heat inputs of the burners, the diameter of the injectors and the working pressures of the various types of gas.

BURNER ARRANGEMENT ON THE HOT PLATE

TABLE

 

BURNERS

 

 

NORMAL

NORMAL

INJECTOR

NORMAL

BY PASS

 

 

GAS

PRESSURE

RATE

DIAMETER

HEAT INPUT (W)

DESCRIPTION

 

 

mbar

g/h

l/h

1/100 mm

Min.

Max.

1/100 mm

 

 

 

 

 

 

 

 

 

 

1

ULTRA RAPID

G 30 - BUTANE

28 - 30

225

 

90

1400

3100

62

G 31 - PROPANE

37

222

 

90

1400

3100

62

 

 

G 20 - NATURAL

20

 

295

121 Y

1400

3100

Adj.

 

 

 

 

 

 

 

 

 

 

2

RAPID

G 30 - BUTANE

28 - 30

204

 

83

800

2800

45

G 31 - PROPANE

37

200

 

83

800

2800

45

 

 

G 20

- NATURAL

20

 

267

117 S

800

2800

Adj.

 

 

 

 

 

 

 

 

 

 

 

3

SEMIRAPID

G 30

- BUTANE

28 - 30

127

 

65

500

1750

35

G 31

- PROPANE

37

125

 

65

500

1750

35

 

 

G 20

- NATURAL

20

 

167

97 Z

500

1750

Adj.

 

 

 

 

 

 

 

 

 

 

4

AUXILIARY

G 30 - BUTANE

28 - 30

73

 

50

400

1000

30

G 31 - PROPANE

37

71

 

50

400

1000

30

 

 

G 20 - NATURAL

20

 

95

72 X

400

1000

Adj.

 

 

 

 

 

 

 

 

 

 

 

FIG. 13

10

Image 10
Contents Instructions Manual Description of the HOT Plates USE HOW to USE the BurnersBurners AIR Inlet see Installation Chapter Paragraphs 5 Cleaning HOT PlateInstalling the HOT Plate InstallationTechnical Information For the Installer Fixing the HOT PlateLocation and Aeration Important Installation InstructionsRoom Ventilation GAS ConnectionElectrical Connection Reduced rate adjustment AdjustmentsOur burners do not require primary air adjustment TapsReplacing the Injectors ConversionsBurner Arrangement on the HOT Plate Replacing HOT Plate Parts ServicingGreasing the taps see Cable Types and Sections Technical Data on the Data Label Technical Assistence and Spare Parts Mark Model SeriesKüchentechnik